Search/Navigation:
Related:
SLAC/EPP
/HPS Public
Jefferson Lab/Hall B
/HPS Run Wiki
S30XL-LESA/LDMX
Confluence will be unusable 23-July-2024 at 06:00 due to a Crowd upgrade.
Half-module # | Contains Hybrid | Contains Sensor | Sensor Glued | Bias Foil Glued | Sent to UCSC | Wirebonded | QA Tested | Pinholes Sector A | Pinholes Sector B | Results | Sent to SLAC | Pigtail potted | Encapsulated | Known issues (QA) | Where is it? | QA warm | QA cold | QA summary | Mounted to cooling structure | Final module (detector) assignment |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0 | Hybrid 0 | ??? | 02/01/19 (TKN) | NA | ??? | 02/05/19 (FM) | ??? | (0), 44, 76, 93, 96, 124, 138, 142, 170, 204, 207, 227, 237, 248, 249 | (0), 98, 113, 233, 250 | Gimp Testing | ??? | So many pinholes | SLAC dry box: PLASTIC | |||||||
1 | Hybrid 1 | W09-S5 | 03/06/19 (CB) | 03/07/19 (CB) | 03/08/19 (CB) | 03/14/19 (FM) | 03/13/2019 (AS) | 122, 225, 248 | (0), 17, 37, 48, 58, 59, 60, 106, 107, 122, 144, 161, 226, 231 | L0M01 Half-Module | Pinholes don't match! | SLAC dry box: CERAMIC | ||||||||
2 | Hybrid 2 | W07-S3 | 03/06/19 (TKN) | 03/07/19 (TKN) | 03/08/19 (CB) | 03/13/19 (FM) | 03/13/2019 (AS) | 28, 65, 193, 194 | (0), 10, 37, 48, 57, 88, 112, 143, 165, 199, 200, 227, 234, 246 | L0M02 Half-Module | Reached 20 uA at 130V | SLAC dry box: CERAMIC | ||||||||
3 | Hybrid 3 | W10-S4 | 4/5/19 (CB/TKN) | N/A | 04/11/19 (CB) | 04/12/2019 (AS) | UCSC | |||||||||||||
4 | Hybrid 4 | W02-S4 | 03/15/19 (TKN) | 03/18/19 (CB/TKN) | 03/21/19 (CB) | 03/22/19 (FM) | L0M04 Half-Module | Excessive Pinholes Not Cleaned | SLAC CR | |||||||||||
5 | SLAC dry box: PLASTIC | |||||||||||||||||||
6 | SLAC dry box: CERAMIC | |||||||||||||||||||
7 | Hybrid 7 | W09-S2 | 3/18/19 (CB/TKN) | 03/20/19 (CB) | 03/21/19 (CB) | 03/22/19 (FM) | L0M07 Half Module | SLAC CR | ||||||||||||
8 | Hybrid 8 | W03-S6 | 3/15/19 (CB/TKN) | 03/18/19 (CB/TKN) | 03/21/19 (CB) | 03/22/19 (FM) | L0M08 Half-Module | Excessive Pinholes Not Cleaned | SLAC CR | |||||||||||
9 | Hybrid 9 | W04-S3 | 3/19/19 (CB/TKN) | 03/20/19 (CB) | 03/21/19 (CB) | 03/22/19 (FM) | SLAC CR | |||||||||||||
10 | Hybrid 10 | W07-S5 | 3/19/19 (CB/TKN) | 03/20/19 (CB) | 03/21/19 (CB) | 03/22/19 (FM) | L0M10 Half-Module | Pinholes don't match! | SLAC CR: DRYBOX cERAMIC | |||||||||||
11* | Hybrid 11 | W07-S4 | 4/5/19 (CB/TKN) | N/A | 04/11/19 (CB) | 04/12/2019 (AS) | Bizzare noise. Many Pinholes | UCSC | ||||||||||||
12* | Hybrid 12 | W04-S6 | 3/25/19 (CB/TKN) | 3/26/19 (CB) | 3/26/19 (CB) | 3/26/19 (FM) | L0M12 Half-Module | Pinholes don't match! | ||||||||||||
13 | Hybrid 13 | W11-S5 | 4/9/19 (CB/TKN) | N/A | 04/11/19 (CB) | 04/11/19 (FM) | 04/11/19 (CB) | L0M13 Half-Module | Pinholes don't match! | SLAC dry box: pLASTIC | ||||||||||
14 | SLAC dry box: PLASTIC | |||||||||||||||||||
15 | Hybrid 15 | W10-S3 | 4/8/19 (CB/TKN) | N/A | 04/11/19 (CB) | 04/12/2019 (FM) | 04/12/2019 (AS) | UCSC | ||||||||||||
16 | Hybrid 16 | W11-S1 | 4/8/19 (CB/TKN) | N/A | 04/11/19 (CB) | 04/12/2019 (FM) | 04/12/2019 (AS) | UCSC | ||||||||||||
17 | Hybrid 17 | W11-S3 | 4/16/19 (CB/TKN) | N/A | 04/19/19 (CB) | 04/19/19 (FM) | 04/19/2019 (AS) | |||||||||||||
18 | Hybrid 18 | W11-S6 | 4/16/19 (CB/TKN) | N/A | 04/19/19 (CB) | 04/19/19 (FM) | 04/19/2019 (AS) | |||||||||||||
19 | Hybrid 19 | W10-S1 | 4/17/19 (CB/TKN) | N/A | 04/19/19 (CB) | 04/19/19 (FM) | 04/19/2019 (AS) | |||||||||||||
20 | Hybrid 20 | W10-S6 | 4/16/19 (CB/TKN) | N/A | 04/19/19 (CB) | 04/19/19 (FM) | 04/19/2019 (AS) | |||||||||||||
21 | Hybrid 21 | W11-S4 | 4/18/19 (CB/TKN) | N/A | 04/19/19 (CB) | 04/19/19 (FM) | 04/19/2019 (AS) | SLAC dry box: CERAMIC | ||||||||||||
22 | Hybrid 22 | W11-S2 | 4/18/19 (CB/TKN) | N/A | 04/19/19 (CB) | 04/19/19 (FM) | 04/19/2019 (AS) |