2019/03/22

Pinholes have been pulled.

0V bias

50V bias

2019/03/22
L0M07 half module, 0V bias baseline_config, fully bonded. Pinholes have been pulled
Sector B Sector A
pCH | apvCH | 128+apvCH | 2*128-apvCH-1| 128-apvCH-1
APV0
0 | 0 | 128 | 255 | 127
73 | 73 | 201 | 182 | 54
APV1
171 | 43 | 171 | 212 | 84
237 | 109 | 237 | 146 | 18
245 | 117 | 245 | 138 | 10
APV2
314 | 58 | 186 | 197 | 69
323 | 67 | 195 | 188 | 60
352 | 96 | 224 | 159 | 31
APV3
467 | 83 | 211 | 172 | 44
503 | 119 | 247 | 136 | 8
511 | 127 | 255 | 128 | 0
Nlow: 11

2019/03/22

High Voltage Tests
V/D:I/D
(V) (uA)
50 1.33
100 1.43
200 1.61
300 2.52
400 9.60
500 20.11

Low Voltage Tests
Pre-Config
V/D:I/D
(V) (A)
AVDD: 2.50 0.106
DVDD: 2.50 0.240
V125: 1.250 0.000

Post-Config
V/D:I/D
(V) (A)
AVDD: 2.50 0.267
DVDD: 2.50 0.245
V125: 1.25 0.224

  • No labels