High Voltage Test
(V) (uA)
V:D/I:D
10 0.27
50 0.39
100 0.46
200 0.81
250 1.03
300 3.47
400 12.00
430 13.97
Low Voltage Test
(V) (A)
V:D/I:D
Pre-Config
AVDD: 2.50 0.106
DVDD: 2.50 0.239
V125: 1.25 0.000
Post-Config
AVDD: 2.50 0.265
DVDD: 2.50 0.244
V125: 1.25 0.230
Bad Channel Table
Sector B Sector A
pCH | apvCH | 128+apvCH | 2*128-apvCH-1| 128-apvCH-1
APV0
0 | 0 | 128 | 255 | 127
118 | 118 | 246 | 137 | 9
APV1
204 | 76 | 204 | 179 | 51
APV2
302 | 46 | 174 | 209 | 81
305 | 49 | 177 | 206 | 78
308 | 52 | 180 | 203 | 75
340 | 84 | 212 | 171 | 43
352 | 96 | 224 | 159 | 31
APV3
406 | 22 | 150 | 233 | 105
462 | 78 | 206 | 177 | 49
488 | 104 | 232 | 151 | 23
493 | 109 | 237 | 146 | 18
511 | 127 | 255 | 128 | 0
Nlow: 13
Baseline Configuration 0V Bias:
50V Bias: