Search/Navigation:
Related:
SLAC/EPP/HPS Public
Jefferson Lab/Hall B/HPS Run Wiki
S30XL-LESA/LDMX
20190412
L0M15 halfmodule, APVS bonded, pinholes pulled
High Voltage Test
(V) (uA)
V:D/I:D
50 0.41
100 0.47
200 0.66
300 2.34
337 20.0
Low Voltage Test
(V) (A)
V:D/I:D
Pre-Config
AVDD: 2.50 0.107
DVDD: 2.50 0.240
V125: 1.25 0.000
Post-Config
AVDD: 2.50 0.314
DVDD: 2.50 0.245
V125: 1.25 0.234
Bad Channel Table
Sector B Sector A
pCH | apvCH | 128+apvCH | 2*128-apvCH-1| 128-apvCH-1
APV0
0 | 0 | 128 | 255 | 127
APV1
204 | 76 | 204 | 179 | 51
231 | 103 | 231 | 152 | 24
APV2
258 | 2 | 130 | 253 | 125
304 | 48 | 176 | 207 | 79
337 | 81 | 209 | 174 | 46
378 | 122 | 250 | 133 | 5
APV3
399 | 15 | 143 | 240 | 112
436 | 52 | 180 | 203 | 75
511 | 127 | 255 | 128 | 0
Nlow: 10
Baseline_config 0V bias
Baseline_config 50V bias + icalScan45 cg0 at 50V