Search/Navigation:
Related:
SLAC/EPP/HPS Public
Jefferson Lab/Hall B/HPS Run Wiki
S30XL-LESA/LDMX
20190412
L0M11 half module pinholes pulled
High Voltage Test
(V) (uA)
V:D/I:D
100 5.35
200 6.33
300 8.93
400 14.31
473 20.08
Low Voltage Test
(V) (A)
V:D/I:D
Pre-Config
AVDD: 2.50 0.106
DVDD: 2.50 0.241
V125: 1.25 0.000
Post-Config
AVDD: 2.50 0.294
DVDD: 2.50 0.245
V125: 1.25 0.226
Bad Channels Table:
Sector B Sector A
pCH | apvCH | 128+apvCH | 2*128-apvCH-1| 128-apvCH-1
APV0
0 | 0 | 128 | 255 | 127
9 | 9 | 137 | 246 | 118
11 | 11 | 139 | 244 | 116
15 | 15 | 143 | 240 | 112
17 | 17 | 145 | 238 | 110
19 | 19 | 147 | 236 | 108
52 | 52 | 180 | 203 | 75
62 | 62 | 190 | 193 | 65
63 | 63 | 191 | 192 | 64
89 | 89 | 217 | 166 | 38
95 | 95 | 223 | 160 | 32
104 | 104 | 232 | 151 | 23
107 | 107 | 235 | 148 | 20
115 | 115 | 243 | 140 | 12
APV1
144 | 16 | 144 | 239 | 111
166 | 38 | 166 | 217 | 89
186 | 58 | 186 | 197 | 69
APV2
265 | 9 | 137 | 246 | 118
302 | 46 | 174 | 209 | 81
303 | 47 | 175 | 208 | 80
311 | 55 | 183 | 200 | 72
312 | 56 | 184 | 199 | 71
349 | 93 | 221 | 162 | 34
358 | 102 | 230 | 153 | 25
373 | 117 | 245 | 138 | 10
APV3
393 | 9 | 137 | 246 | 118
413 | 29 | 157 | 226 | 98
427 | 43 | 171 | 212 | 84
429 | 45 | 173 | 210 | 82
444 | 60 | 188 | 195 | 67
447 | 63 | 191 | 192 | 64
497 | 113 | 241 | 142 | 14
502 | 118 | 246 | 137 | 9
511 | 127 | 255 | 128 | 0
Nlow: 34
Baseline Configuration FitNoise after pinholes pulled at 0V bias:
Baseline Configuration and icalScan 45 at 50v Bias: