Detector requirements
ASICs documentation
Detector Design Concept
- Initial design concept revision A (2019) presentation (pptx, pdf)
- Initial design concept revision B (2019) presentation (pptx, pdf)
- Electronic system concept (2020) presentation (pptx, pdf)
- Electronic system concept (2022) presentation (pptx, pdf)
- IEEE NSS slides (pptx, pdf)
Prototype design concept
Mechanical design
- Thermal analyses
Electronics Design
Grounding (pptx)
Tile board
Data concentrator
Mother board
System ground concept
Board Design files
Prototype Bring-up
Fpga Documentation
Cables
PCIe card firmware
Power Supply
- Power supply should provide 24V
- Expected power consumption is 7W per ASIC plus 25W for the readout boards totalling 53W
- Power supplies capable of single channel 75W or more is acceptable but recommend is 2 channels with 50W each
- Examples of such supplies
- HMP4030 bench supply. 3 channels up to 160W each. This is the supply used in the lab for testing
- MPOD (https://www.wiener-d.com/product/mpod-lv-module/) compatible modules (using 2 channels of 24V)
MPV 8030I | 8 | 0 - 30V | 2.5A | 50W / ch. | 2mV | 0.12mA | <2mVpp |
MPV 8030I | 8 | 0 - 30V | 2.5A | 50W / ch. | 2mV | 0.12mA | <2mVpp |
- MPOD compatible modules (using 1 or 2 channels of 24V)
MPV 4030I | 4 | 0 - 30V | 5A | 100W / ch. | 2mV | 0.12mA | <2mVpp |
Operating the detector
Meetings
- New site to be used from 02/2023 forward https://confluence.slac.stanford.edu/x/7YBAFg
- Meeting on 02/18/2021
- Flex boards and wire thickness discussions (ppt)
- Next step is simulate the stress caused by 10, 12 and14 layer flex assuming ePixHR flex stack up as reference for each layer definition.
- Meeting on 09/02/2021
- Slide from Angelo and Dionisio (ppt)
Mecanical model
- Team center
- Carrier insertion and extraction tool (DSG-000022848_3)
- Key drawings in pdf
Assembly
Data communication protocol
Image definition
Register map
Timing emulator
Sensors Documentation
- Design files
- Test Documents
- etc.
Detector Modules
Software ID | Digital SN | P&CB SN | Carrier SN | Cooling | Location | Notes |
---|
0016778240-0176075265-0452984854-4021594881-1962934296-0177446913-0402653206 | C00-03 | BT-02-23 | 24-C00-01 (RX-001) | 16C | Fee Alcove | Thin entrance sensor 4 V4 ASICs |
0016777984-4294967295-4294967295-4032267777-3204448280-0177427457-3053453334 | C00-01 | 26-C01-01 | John Doe | 18 | ASC | not thin 4 ASICs |
| C00-02 | BT-02-23 | 24-C00-08 (RX-000) | 18 | IC lab | Thin entrance sensor 2 V2 ASICs |
|
|
|
|
|
|
|
|
|
|
|
|
|
|