Identification Details and Hardware Changelog


Nominal Operating Voltages and Currents

Ch.LineVI





Performance Measures

Experiment=detdaq18, Run=222 (Date)

Pedestal Summary

Method:  Dark environment, nominal operation, collect 1000 frames @120Hz.  Generate per-pixel mean and standard deviation over 1000 frames.  Pixels more than 3 sigma out of detector-wide mean are flagged bad.  Files archived as xxxx

Gain ModeMean Ped Value (ADU)

Number of NCP

FH3268 ± 2314829
FM3205 ± 2254777
FL3175 ± 2214758
AHL3271 ± 2294842
AML3207 ± 2244797
                                                                                                               


     Pedestal NCP Map

Noise Summary

Gain ModeVariation (sigma)Number of NCP, Map
FH6419276
FM3393224
FL2402881
AHL7133023
AML3383411
      Noise NCP Map

Gain and uniformity (photon source)

Gain ModeNumber of Gain NCP, Map
FH

 1

FM 1
FL 6017
AHL157
AML 71
     

Linearity (signal injection)

Thermal measurements (all thermometers)

Experiment History


ExperimentHutchShiftsDate Deployed