Description of detectors supported by the department - specs, description, deployment, calibration (question), default register settings, etc.  Link to trackers?

Notes:

  • Likely detector movements for week of 10/28: ePix100 "quad" to XCS on Mon 10/28 (etches ?, ?, ?, ?)

Detector inventory and location.

Last updated: 10/25/2024


no.Detectorconfigno.locationnoteSerial ID
Gain calibrated? (Cu)
ePix10k

1ePix10kafront28ASC
3791912962-0170007809-3607101462-1663404124-0001354881-3000606721-2650800153
2ePix10kafront27ASC
3791912962-0169813761-2634022934-1663404124-0003153025-2400372737-3489660952
3ePix10kaside (1mm Si)36ASC
3791912962-0174726657-1493172246-0288141332-0001315112-4095719425-3607101466
4ePix10kafront31TIDMarginal detector. For development, not operations (in Xavier's drawer)

5ePix10kQuad
Q6UED360Hz detector.

6ePix10kQuad
MEC Q0MEC
All module IDs
7ePix10kQuad
MEC Q1MEC
All module IDs
8ePix10kQuad
MEC Q2

MEC


All module IDs
9ePix10kQuad
MEC Q3MEC
All module IDs
10ePix10kQuad
MEC Q4ASC
All module IDs
11ePix10kQuad
MEC Q5ASC
All module IDs
12ePix10k2M.0
0XCS 
All module IDs
13ePix10k2M.1
1MFX One tile acting upAll module IDs
ePix100

14ePix100side34TIDnever worked? 

15ePix100front30XPP
3925999620-171598081-1879048214-1794135040-1745668107-2998264677-2181038105yes
16ePix100front25XCS
3925999620-1000686337-1174405130-3104330752-0681854067-2671186177-3472883735only Ag
17ePix100front12XCS
3925999620-1000248321-4076863498-1794137088-0410306571-2402454273-0067108888yes
18ePix100front11MEC
3925999620-0996663297-3791650826-1232098304-0953206283-2655595777-0520093719
19ePix100front10XCS
3925999620-0996513537-2080374794-1794135040-0940361739-2398406657-0419430424yes
20ePix100front9ASC2 unresponsive banks, use as last resort3925999620-0996432897-3590324234-1232100352-1154532875-2654088449-0033554455yes but see "Notes" column
21ePix100front8XCSsample residue on kapton cover, awaiting film replacement

3925999620-0996579585-0553648138-1232098304-1221641739-2650251521-3976200215

yes

22ePix100front7MEC
3925999620-0999521281-2533359626-1794137088-1745668107-2398940417-2046820376
23ePix100front5
perhaps MEC? Can't find last use.3925999620-0997249025--0570425354-0629691392-0337412451-2397900801-4076863512
24ePix100front4XCS

3925999620-0998275585-0385875978-1232100352-0416335371-2654033921-1056964631

yes

25ePix100sideS1
missing (sad)3925999620-1000144641-1258291210-0629693440-0611090787-2995437313-0973078553only Ag
26ePix100sideS2MFX
3925999620-0997117953-4227858442-1794137088-0403490827-2403244545-1224736792yes
Jungfrau

27JF0.5M

XCS


28JF1M

XPP


29JF4M

CXI


RIXS-CCD

30RIXS-CCD

RIXSSTA52000 SN31201

31RIXS-CCD

ASCSTA52000 SN31179

CSPAD

32CSPAD 2M

CXI


Prototypes

33ePix10kafront42ASCnon-ghosting prototype

34ePix10kaNfront26ASCGaAs

35ePix10kaNfront??TIDCdZnTe

36ePix10kaNfrontGe2ASCGe2. Only modules. This module has the H pattern on the ASIC outside the sensor.

37ePix10kaNfront??TIDGe

38ePix10kaNfront??TID

Ge



39ePixHRfrontH01ASC

ASIC v4.

can hold full bias. Partially connected sensor


40ePixHRfrontno etchASC

ASIC v4.

fill sensor connected, can only hold bias to 80V


41ePixMside
ASC




42ePix250Sfront22ASC