SVT EPICS Power Instructions

DAQ & Power Mapping in Group C

Operation

!!! Remember to make sure the detector is being cooled. !!!

!!! Remember to make sure the interlocks are in the state you want them. !!!

Remote control of hardware

Interlock board: see Group C interlock board for instructions on monitoring and controls.

Serial portserver (Digi Portserver TS 4): 192.168.1.217 on LAN. Telnet from ppa-pc91245, e.g. "telnet 192.168.1.217 2001" will connect you to port 2001. All serial ports are logged to /var/log/portserver on ppa-pc91245. Configure the portserver using its web interface or Telnet. Docs: http://www.digi.com/support/productdetail?pid=1954

PortTelnet portHardwareUseful for
12001BK 1697 power supply, powering interlock boardresetting interlock board: SOUT000 to turn on, SOUT001 to turn off
22002  
32003  
42004  

 

Basic instructions to take a pedestal run with CODA

...

Check that the hybrid currents measured are ok. Sync status for each channel can be seen in register RceCore/DataPath[x]/Synced, 1xf for powered channels. 

 

Test Run SVT Group C Setup

...