Beginning November 4, 2024, login to Confluence and Jira will change. Read more.
- Parker translation stage 404-R. 50m
- Move the motor with IMS terminal to access the mounting bolts.
- Dismount the stage from the black anodized bracket it came with.
-
- Remove original magnetic limit switches and harness from stage.
- Mount new limit switch brackets in the channel on the side of the stage.
- Mount new switches into switch holder brackets.
- Remove pin 8 from 14 pin molex (IMS I/O connector)
- Insert pin into pin 8 of the motor protection board. This is going to be the brake power input.
- Mount new Motor Protection Board on the existing motor. Use this: Board schematics for motor controlled brake.
- Mount new switches into switch holder brackets.
- Terminate limit switch wiring.
- The positive switch wire goes to pin 1 of the 6 pin molex.
- The negative switch wire goes to pin 2 of the 6 pin molex.
- Pins 3 & 4 are for the common wires.
- Connect the switch harness connector to the MPB and test the limits .
-