  • Parker translation stage 404-R. 50m
    • Remove original magnetic limit switches and harness from stage.
    • Mount new limit switch brackets in the channel on the side of the stage.
    • Remove pin 8 from 14 pin molex (IMS I/O connector)
    • Insert pin into pin 8 of the motor protection board. This is going to be the brake power input. 
    • Mount new Motor Protection Board on the existing motor. Use this: Board schematics for motor controlled brake. 
    • Mount new switches into switch holder brackets.
    •  .
  •  