You are viewing an old version of this page. View the current version.
Compare with Current
View Page History
Version 1
Next »
- Parker translation stage 404-R. 50m
- Remove original magnetic limit switches and harness from stage.
- Mount new limit switch brackets in the channel on the side of the stage.
- Remove pin 8 from 14 pin molex (IMS I/O connector)
- Insert pin into pin 8 of the motor protection board. This is going to be the brake power input.
- Mount new Motor Protection Board on the existing motor. Use this: Board schematics for motor controlled brake.
- Mount new switches into switch holder brackets.