Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

    • The requirements come from the following list:
      Photon runs
      ------------
      2 cerenkov
      1 large plastic (1cm thick) for rate monitoring
      2 finger counters (2mm thickness, overlap of 1x1cm) for triggering
      1 large plastic (1cm thick) with a 24mm diameter hole centered on the
      beam for vetoing background
      2 XY silicon layers before the magnet
      1 magnet
      2 XY silicon layers after the magnet
      1 plastic (1cm thick) after the last silicon for triggering*          Comment

comment: we might deplete the 2nd cerenkov to reduce X0 if we realize
that the photon trigger is efficient

Electron runs
--------------

...


...

2 cerenkov

...

1 large plastic (1cm thick) for rate monitoring

...

2 finger counters (2mm thickness, overlap of 1x1cm) for triggering

...

1 large plastic (1cm thick) with a 24mm diameter hole centered on the

...

beam for vetoing background

...

1 XY silicon layers before the magnet

...

1 magnet OFF

comment: we might need a trigger scintillator in coincidence with the
fingers just before the CU

Positron

...

runs
           --------------
                   2 cerenkov
                   1 large plastic (1cm thick) for rate monitoring
                   2 finger counters (2mm thickness, overlap of 1x1cm) for triggering
                   1 large plastic (1cm thick) with a 24mm diameter hole centered on the
                     beam for vetoing background
                   1 XY silicon layers before the magnet
                   1 magnet ON
                   1 EM CAL (40cm NaI) to veto gammas
                   1 plastic after the annihilator before the CU to veto electron/positron Proton Runs*  

Proton runs
          --------------
          2 cerenkov
          1 large plastic (1cm thick) for rate monitoring
          2 finger counters (2mm thickness, overlap of 1x1cm) for triggering
          1 large plastic (1cm thick) with a 24mm diameter hole centered on the
          beam for vetoing background
          1 XY silicon layers before the magnet
          1 magnet OFF

          comment: we might need a trigger scintillator in coincidence with the
          fingers just before the CU

         general comment: the veto counter (plastic with hole) might be removed
         if background is measured to be low enough