Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • The geometry of the PS setup actually used is described very well by Stefan
  • Other setups are in progress.
    • The requirements come from the following list:
    • Photon runs
      ------------
      2 cerenkov
      1 large plastic (1cm thick) for rate monitoring
      2 finger counters (2mm thickness, overlap of 1x1cm) for triggering
      1 large plastic (1cm thick) with a 24mm diameter hole centered on the
      beam for vetoing background
      2 XY silicon layers before the magnet
      1 magnet
      2 XY silicon layers after the magnet
      1 plastic (1cm thick) after the last silicon for triggering

...

    • *           Comment: we might deplete the 2nd cerenkov to reduce X0 if we realize

...

    • that the photon trigger is efficient
                Electron runs
                --------------
                2 cerenkov
                1 large plastic (1cm thick) for rate monitoring
                2 finger counters (2mm thickness, overlap of 1x1cm) for triggering
                1 large plastic (1cm thick) with a 24mm diameter hole centered on the
                beam for vetoing background
                1 XY silicon layers before the magnet
                1 magnet OFF

          comment: we might need a trigger scintillator in coincidence with the
          fingers just before the CU

          Positron runs
          --------------
          2 cerenkov
          1 large plastic (1cm thick) for rate monitoring
          2 finger counters (2mm thickness, overlap of 1x1cm) for triggering
          1 large plastic (1cm thick) with a 24mm diameter hole centered on the
          beam for vetoing background
          1 XY silicon layers before the magnet
          1 magnet ON
          1 EM CAL (40cm NaI) to veto gammas
          1 plastic after the annihilator before the CU to veto electron/positron

          Proton runs
          --------------
          2 cerenkov
          1 large plastic (1cm thick) for rate monitoring
          2 finger counters (2mm thickness, overlap of 1x1cm) for triggering
          1 large plastic (1cm thick) with a 24mm diameter hole centered on the
          beam for vetoing background
          1 XY silicon layers before the magnet
          1 magnet OFF

          comment: we might need a trigger scintillator in coincidence with the
          fingers just before the CU

         general comment: the veto counter (plastic with hole) might be removed
         if background is measured to be low enough