Test run sensor production

Sensor #

Received

Tested

V dep (V)

V break (V)

Pinholes

Shorts

Opens

Glued to carbon fiber

Part of half-module

Notes

Sensor 132

7/13/11(AG)

(HPK)(UCSC)

110

>1000

-

-

-

3/11/12(TKN/PH)

Half-module 3

COMPLETE

Sensor 134

7/13/11(AG)

(HPK)(UCSC)

110

>1000

-

-

-

3/11/12(TKN/PH)

Half-module 4

COMPLETE

Sensor 136

7/13/11(AG)

(HPK)(UCSC)

110

>1000

-

-

-

3/11/12(TKN/PH)

Half-module 5

COMPLETE

Sensor 138

7/13/11(AG)

(HPK)(UCSC)

110

>1000

-

-

-

3/18/12(TKN)

Half-module 6

COMPLETE

Sensor 139

7/13/11(AG)

(HPK)(UCSC)

110

520

-

-

-

?

Half-module ?

In test jig at UCSC

Sensor 140

7/13/11(AG)

(HPK)(UCSC)

110

>1000

-

-

-

3/18/12(TKN)

Half-module 7

COMPLETE

Sensor 141

7/13/11(AG)

(HPK)(UCSC)

110

>1000

-

-

-

3/18/12(TKN)

Half-module 8

COMPLETE

Sensor 142

7/13/11(AG)

(HPK)(UCSC)

110

>1000

-

-

-

?

Half-module 9

COMPLETE

Sensor 143

7/13/11(AG)

(HPK)(UCSC)

120

>1000

80,106,232,240,255,371

-

-

?

Half-module ?

READY

Sensor 144

7/13/11(AG)

(HPK)(UCSC)

110

>1000

-

432,433

-

3/27/12(TKN)

Half-module 21

COMPLETE

Sensor 145

7/13/11(AG)

(HPK)(UCSC)

110

>1000

-

-

-

?

Half-module 10

COMPLETE

Sensor 146

7/13/11(AG)

(HPK)(UCSC)

110

>1000

-

-

-

?

Half-module 11

COMPLETE

Sensor 147

7/13/11(AG)

(HPK)(UCSC)

120

>1000

-

-

-

3/22/12(TKN)

Half-module 12

COMPLETE

Sensor 150

7/13/11(AG)

(HPK)(UCSC)

120

>1000

-

-

-

3/1/12(TKN)

Half-module 2

COMPLETE

Sensor 152

7/13/11(AG)

(HPK)(UCSC)

120

600

-

-

-

?

Half-module ?

MOVED to 2014 Production

Sensor 153

7/13/11(AG)

(HPK)(UCSC)

120

980

-

-

-

3/22/12(TKN)

Half-module 13

COMPLETE

Sensor 155

7/13/11(AG)

(HPK)(UCSC)

110

>1000

-

-

-

3/22/12(TKN)

Half-module 14

COMPLETE

Sensor 156

7/13/11(AG)

(HPK)(UCSC)

110

>1000

-

-

-

3/23/12(TKN)

Half-module 15

COMPLETE

Sensor 157

7/13/11(AG)

(HPK)(UCSC)

120

>1000

-

-

-

3/23/12(TKN)

Half-module 16

COMPLETE

Sensor 159

7/13/11(AG)

(HPK)(UCSC)

110

>1000

-

-

-

3/23/12(TKN)

Half-module 17

COMPLETE

Sensor 563

7/13/11(AG)

(HPK)(UCSC)

130

>1000

-

-

-

3/26/12(TKN)

Half-module 18

COMPLETE

Sensor 564

7/13/11(AG)

(HPK)(UCSC)

130

>1000

-

-

-

3/26/12(TKN)

Half-module 19

COMPLETE

Sensor 565

7/13/11(AG)

(HPK)(UCSC)

130

>1000

-

-

-

3/26/12(TKN)

Half-module 20

COMPLETE

Sensor 566

7/13/11(AG)

(HPK)(UCSC)

130

>1000

-

-

-

3/27/12(TKN)

Half-module 22

COMPLETE

Sensor 567

7/13/11(AG)

(HPK)(UCSC)

130

>1000

-

-

-

3/27/12(TKN)

Half-module 23

COMPLETE

Sensor 568

7/13/11(AG)

(HPK)(UCSC)

130

>1000

-

-

-

2/23/12(TKN)

Half-module 1

COMPLETE

Sensor 597

7/13/11(AG)

(HPK)(UCSC)

120

660

-

-

-

3/30/12(TKN)

Half-module 24

COMPLETE

Sensor 601

7/13/11(AG)

(HPK)(UCSC)

130

>1000

-

-

-

3/30/12(TKN)

Half-module 25

COMPLETE

Sensor 603

7/13/11(AG)

(HPK)(UCSC)

130

>1000

623

-

-

4/1/12(TKN)

Half-module 27

COMPLETE

Sensor 604

7/13/11(AG)

(HPK)(UCSC)

130

>1000

-

-

-

3/30/12(TKN)

Half-module 26

COMPLETE

Sensor 1800

2/7/11(TKN)

(HPK)(UCSC)

150 (*)

>1000

-

-

-

?

Half-module ?

Has bond feet from wirebond testing

Sensor 1801

2/7/11(TKN)

(HPK)(UCSC)

150 (*)

>1000

-

-

-

4/1/12(TKN)

Half-module 28

COMPLETE

Sensor 1802

2/7/11(TKN)

(HPK)(UCSC)

150 (*)

>1000

-

-

-

4/1/12(TKN)

Half-module 29

COMPLETE

Sensor 1803

2/7/11(TKN)

(HPK)(UCSC)

150 (*)

>1000 (varied after scratch)

-

-

-

?

Half-module 0

COMPLETE

Test run hybrid production

Hybrid #

Received

Passive components loaded / cleaned

Sent to UCSC

APV25s loaded

Wirebonded

Tested

Results

Sent to SLAC

Glued to carbon fiber

Part of half-module

Notes

Hybrid 0

10/10/11(RH)

?

?

?

?

test 1

?

?

?

Half-module 0

COMPLETE

Hybrid 1

10/10/11(RH)

?

2/1/12(PH,VF)

2/1/12(FM)

2/3/12(FM)

2/14/12 OM test 1

OK

2/22/12(OM)

2/23/12(TKN)

Half-module 1

COMPLETE

Hybrid 0t

2/21/12(RH)

2/22/12(RH)

2/23/12(AG)

2/24/12(FM)

2/27/12(FM)

2/29/12 OM test 1

OK

2/29/12(OM)

3/1/12(TKN)

Half-module 2

COMPLETE

Hybrid 1t

2/21/12(RH)

3/5/12(RH/PH)

3/5/12(PH)

3/6/12(FM)

3/7/12(FM)

3/7/12(OM) test 1

OK

3/7/12(JN)

3/10/12(TKN)

Half-module 3

COMPLETE

Hybrid 2t

2/21/12(RH)

3/5/12(RH/PH)

3/5/12(PH)

3/6/12(FM)

3/7/12(FM)

3/7/12(OM) test 1

OK

3/7/12(JN)

3/10/12(TKN)

Half-module 4

COMPLETE

Hybrid 3t

2/21/12(RH)

3/5/12(RH/PH)

3/5/12(PH)

3/6/12(FM)

3/7/12(FM)

3/7/12(OM) test 1

OK

3/7/12(JN)

3/10/12(TKN)

Half-module 5

COMPLETE

Hybrid 4t

2/21/12(RH)

3/14/12(RH/PH)

3/14/12(PH)

3/14/12(FM)

3/15/12(FM)

3/15/12 (VF, OM) test 1
3/15/12 test 2
3/15/12 test 3
3/16/12 test 4
3/16/12 test 5

Bad channel 466, else OK.

3/16/12 (PH)

3/20/12(TKN)

Half-module 9

COMPLETE

Hybrid 5t

2/21/12(RH)

3/14/12(RH/PH)

3/14/12(PH)

3/14/12(FM)

3/15/12(FM)

3/15/12 (VF)

V125, AVDD, GND shorts => no readout test

3/16/12 (PH)

-

-

-

5t continued

-

-

-

-

-

3/23/12(PH) test 1
3/23/12(PH) test 2
3/23/12(PH) test 3
3/23/12(PH) test 4
3/23/12(PH) test 5
3/23/12(PH) test 6

After connector pinout fixed: channel 417 dead, else OK

-

3/27/12(TKN)

Half-module 21

COMPLETE 

Hybrid 6t

2/21/12(RH)

3/14/12(RH/PH)

3/14/12(PH)

Not loaded, loose connector wire(FM, VF)

back to SLAC

-

-

3/16/12 (PH)

-

-

continued on next line...

6t continued

-

-

3/19/12(TKN/VF)

3/19/12(FM)

3/20/12 (FM)

3/20/12 (OM)
test 1

Bad channel 345, else OK.

3/20/12 (VF)

3/22/12(TKN)

Half-module 12

COMPLETE

Hybrid 7t

2/21/12(RH)

3/15/12(RH/PH/TKN)

3/16/12(PH)

3/16/12 (FM)

3/17/12 (FM)

3/17/12 (TC,VF) test 1

OK

3/18/12 (VF)

3/18/12(TKN)

Half-module 6

COMPLETE

Hybrid 8t

2/21/12(RH)

3/15/12(RH/PH/TKN)

3/16/12(PH)

3/16/12 (FM)

3/17/12 (FM)

3/17/12 (TC,VF) no data
3/18/12 test 1
3/18/12 test 2
3/18/12 test 3

APV0 defective? Could not set defaults => No test results.

?

?

Half-module ?

Needs further testing

Hybrid 9t

2/21/12(RH)

3/15/12(RH/PH/TKN)

3/16/12(PH)

3/16/12 (FM)

3/17/12 (FM)

3/17/12 (TC,VF) test 1

Problems testing with DAQ

3/18/12 (VF)

?

Half-module ?

Needs further testing

Hybrid 10t

2/21/12(RH)

3/15/12(RH/PH/TKN)

3/16/12(PH)

3/16/12 (FM)

3/17/12 (FM)

3/17/12 (TC,VF) test 1

OK

3/18/12 (VF)

3/18/12(TKN)

Half-module 7

COMPLETE

Hybrid 11t

2/21/12(RH)

3/15/12(RH/PH/TKN)

3/16/12(PH)

3/16/12 (FM)

3/17/12 (FM)

3/17/12 (TC,VF) test 1

OK

3/18/12 (VF)

3/18/12(TKN)

Half-module 8

COMPLETE

Hybrid 12t

2/21/12(RH)

3/15/12(RH/PH/TKN)

3/16/12(PH)

Not loaded, b/c of gauge mark on ASIC pad.

N/A

N/A

N/A

3/18/12 (VF)

?

Half-module ?

Salvage connector?

Hybrid 13t

2/21/12(RH)

3/15/12(RH/PH/TKN)

3/16/12(PH)

3/19/12 (FM)

3/20/12 (FM)

3/20/12 (OM) test 1

OK

3/20/12 (VF)

3/20/12(TKN)

Half-module 10

COMPLETE

Hybrid 14t

2/21/12(RH)

3/15/12(RH/PH/TKN)

3/16/12(PH)

3/19/12 (FM)

3/20/12 (FM)

3/20/12 (OM) test 1

OK

3/20/12 (VF)

3/20/12(TKN)

Half-module 11

COMPLETE

Hybrid 15t

2/21/12(RH)

3/15/12(RH/PH/TKN)

3/16/12(PH)

3/19/12 (FM)

3/20/12 (FM)

3/19/12 (OM) test 1
3/19/12 test 2

OK

3/20/12 (VF)

3/22/12(TKN)

Half-module 13

COMPLETE

Hybrid 16t

2/21/12(RH)

3/15/12(RH/PH/TKN)

3/16/12(PH)

3/19/12 (FM)

3/20/12 (FM)

3/20/12 (OM) test 1

OK

3/20/12 (VF)

3/22/12(TKN)

Half-module 14

COMPLETE

Hybrid 17t

2/21/12(RH)

3/16/12(PH)

3/19/12(TKN/VF)

3/19/12 (FM)

3/20/12 (FM)

3/20/12 (OM) test 1

OK

3/20/12 (VF)

3/23/12(TKN)

Half-module 15

COMPLETE

Hybrid 18t

2/21/12(RH)

3/16/12(PH)

3/19/12(TKN/VF)

3/19/12 (FM)

3/20/12 (FM)

3/20/12 (OM) test 1

OK

3/20/12 (VF)

3/23/12(TKN)

Half-module 16

COMPLETE

Hybrid 19t

2/21/12(RH)

3/16/12(PH)

3/19/12(TKN/VF)

3/19/12 (FM)

3/20/12 (FM)

3/20/12 (OM) test 1

Bad channel 254, else OK

3/20/12 (VF)

3/23/12(TKN)

Half-module 17

COMPLETE

Hybrid 20t

3/21/12(RH)

3/22/12(PH)

3/23/12(PH)

3/23/12(FM)

3/24/12(FM)

3/24/12 (OM,VF) test 1
test 2

OK

3/26/12(VF,PH)

3/26/12(TKN)

Half-module 18

COMPLETE

Hybrid 21t

3/21/12(RH)

3/22/12(PH)

3/23/12(PH)

3/23/12(FM)

3/24/12(FM)

3/24/12 (OM,VF)test 1
test 2

OK

3/26/12(VF,PH)

3/26/12(TKN)

Half-module 19

COMPLETE

Hybrid 22t

3/21/12(RH)

3/22/12(PH)

3/23/12(PH)

3/23/12(FM)

3/24/12(FM)

3/24/12 (OM,VF)test 1

OK

3/26/12(VF,PH)

3/27/12(TKN)

Half-module 22

COMPLETE 

Hybrid 23t

3/21/12(RH)

3/22/12(PH)

3/23/12(PH)

3/23/12(FM)

3/24/12(FM)

3/24/12 (OM,VF)test 1
test 2

OK

3/26/12(VF,PH)

3/27/12(TKN)

Half-module 23

COMPLETE 

Hybrid 24t

3/21/12(RH)

3/22/12(PH)

3/23/12(PH)

3/23/12(FM)

3/24/12(FM)

3/24/12 (OM,VF) test 1
test 2

OK

3/26/12(VF,PH)

3/26/12(TKN)

Half-module 20

COMPLETE

Hybrid 25t

3/21/12(RH)

3/29/12(PH)

3/29/12(PH)

3/29/12(FM)

3/30/12(FM)

3/30/12(OM) test 1
3/30/12test 2

OK

3/30/12(AG,VF)

3/30/12 (TKN)

Half-module 24

COMPLETE

Hybrid 26t

3/21/12(RH)

3/29/12(PH)

3/29/12(PH)

3/29/12(FM)

3/29/12(FM)

3/30/12(OM) test 1

OK

3/30/12(AG,VF)

3/30/12 (TKN)

Half-module 25

COMPLETE

Hybrid 27t

3/21/12(RH)

3/29/12(PH)

3/29/12(PH)

3/29/12(FM)

3/29/12(FM)

3/30/12(OM) test 1

OK

3/30/12(AG,VF)

3/30/12 (TKN)

Half-module 26

COMPLETE

Hybrid 28t

3/21/12(RH)

3/30/12(PH)

3/30/12(AG,VF)

3/30/12(FM)

4/01/12(FM)

4/01/12(VF) test 1

OK

4/1/12(PH)

4/1/12(TKN)

Half-module 28

COMPLETE

Hybrid 29t

3/21/12(RH)

3/30/12(PH)

3/30/12(AG,VF)

3/30/12(FM)

4/01/12(FM)

4/01/12(VF) test 1

OK

4/1/12(PH)

4/1/12(TKN)

Half-module 29

COMPLETE

Hybrid 30t

3/21/12(RH)

3/30/12(PH)

3/30/12(AG,VF)

3/30/12(FM)

4/01/12(FM)

4/01/12(VF) test 1

Chans 203, 300-302 have pronounced baseline tails, others are OK.

4/1/12(PH)

4/1/12(TKN)

Half-module 27

COMPLETE

Test run half-module production

Half-module #

Contains hybrid

Contains sensor

Hybrid glued

Sensor glued

Sent to UCSC

HV wirebonded

Signals wirebonded

QA tested

Results

Sent to SLAC

Mounted to cooling block

Part of module

Notes

Half-module 0 - THE GIMP

Hybrid 0

Sensor 1803

to fixture

lousy

with a prayer

mashed bonds

painfully

? test 1

4 chips bonded, and 4 are alive. 3 of them are both bonded and alive.

?

never

Module ?

 

Half-module 1

Hybrid 1

Sensor 568

2/23/12(TKN)

2/23/12(TKN)

2/23/12(AG)

2/27/12(FM)

2/29/12(FM)

2/28/12 test 1
2/29/12 test 2
3/4/12 test 3

OK: test 2
Baseline tests by PH show high noise in channel 81 - partial pinhole?

3/12/12(TKN)

?

Module T3

READY

Half-module 2

Hybrid 0t

Sensor 150

3/1/12(TKN)

3/1/12(TKN)

3/1/12(OM)

3/2/12(FM)

3/6/12(FM)

3/5/12 test 1
3/7/12 test 2
3/9/12 test 3
3/12/12 test 4
3/12/12 test 5
3/12/12 test 6

OK

3/14/12(PH)

?

Module ?

Damaged signal wirebonds observed: probable shorts first ~40 channels.

Half-module 3

Hybrid 1t

Sensor 132

3/10/12(TKN)

3/10/12(TKN)

3/12/12 (TKN)

3/12/12(FM)

3/13/12(FM)

3/13/12 test 1
3/14/12 (OM, VF) test 2
3/19/12 test 3
3/19/12 test 4

High noise? (To retest) Chan 625 unbonded, 627 dead.
High noise is only on run 2 - believed due to noisy electrical contact between CF and baseplate.

 

 

 

Cont'ed on next line

Cont'ed No 3

 

 

 

 

 

 

Chan 625 fixed, 3/22/12(FM)

3/23/12 test 6

627 dead, else OK: test 6

3/23/12 (PH)

?

Module B3

Needs ITT connector

Half-module 4

Hybrid 2t

Sensor 134

3/10/12(TKN)

3/10/12(TKN)

3/12/12 (TKN)

3/14/12(FM)

3/14/12(FM)

3/16/12 (TC, VF) test 1
3/17/12 test 2

Channels 317, 319 shorted, rest is OK: test 1

3/18/12 (VF)

?

Module B1

READY

Half-module 5

Hybrid 3t

Sensor 136

3/10/12(TKN)

3/10/12(TKN)

3/12/12 (TKN)

3/14/12(FM)

3/14/12(FM)

3/19/12 (VF,OM) test 1
3/19/12 test 2
3/19/12 test 3
3/19/12 test 4
3/19/12 test 5
3/19/12 test 7

OK: test 5 (but cal7_8x3_125ns is bad for this run)

3/23/12(PH)

?

Module B5

Needs ITT connector

Half-module 6

Hybrid 7t

Sensor 138

3/18/12(TKN)

3/18/12(TKN)

3/19/12 (TKN/VF)

3/21/12(FM) noticed scratch on Bias/Guard rings. But IV is OK up to 300V.

3/22/12(FM)

3/22/12 test 1
3/22/12 test 2

OK except channels 0 (no response), 134, 639 (noisy response). Channel 0 is bad b/c of the scratch that connects it with bias ring.

3/23/12(PH)

?

Module T2

READY

Half-module 7

Hybrid 10t

Sensor 140

3/18/12(TKN)

3/18/12(TKN)

3/19/12 (TKN/VF)

3/21/12(FM)

3/22/12(FM)

3/23/12 test 1
3/23/12 test 2
3/23/12 test 3
3/23/12 test 4
3/23/12 test 5
3/23/12 test 6
3/23/12 test 7
3/23/12 test 8
3/23/12 test 9
3/27/12 test 10
3/27/12 test 11

OK: test 11

3/27/12(OM)

?

Module B5

READY

Half-module 8

Hybrid 11t

Sensor 141

3/18/12(TKN)

3/18/12(TKN)

3/19/12 (TKN/VF)

3/21/12(FM)

3/21/12(FM)

3/23/12 test 1
3/26/12 test 2
3/26/12 test 3

OK: test 3

3/27/12(OM)

?

Module B4

READY

Half-module 9

Hybrid 4t

Sensor 142

3/20/12(TKN)

3/20/12(TKN)

3/21/12(DG)

3/23/12(FM)

3/23/12(FM)

3/26/12 test 1

Channel 466 has no response (as on hybrid), else OK.

3/27/12(OM)

?

Module B2

READY

Half-module 10

Hybrid 13t

Sensor 145

3/20/12(TKN)

3/20/12(TKN)

3/21/12(DG)

3/23/12(FM)

3/23/12(FM)

3/26/12 test 1
3/27/12 test 2
3/27/12 test 3
3/27/12 test 4
3/28/12 test 5
3/28/12 test 6

Channels 81 and 83 shorted? Else OK.
All channels are OK from test 3 on.

3/27/12(PH)

?

Module T5

READY

Half-module 11

Hybrid 14t

Sensor 146

3/20/12(TKN)

3/20/12(TKN)

3/21/12(DG)

3/23/12(FM)

3/23/12(FM)

3/26/12 test 1
3/27/12 test 2
3/27/12 test 3
3/28/12 test 4
3/28/12 test 5
3/28/12 test 6
3/28/12 test 7
3/28/12 test 8
3/28/12 test 9
3/28/12 test 10
3/28/12 test 11

Shorts between channels 262 and 264 as well as between channels 403 and 405; channel 183 dead and high noise on channel 184; else OK.
262-264 and 403-405 appear to have been fixed as of test 3: test 10

3/27/12(PH)

?

Module ?

READY

Half-module 12

Hybrid 6t

Sensor 147

3/22/12(TKN)

3/22/12(TKN)

3/23/12(PH)

03/27/12(FM)

03/27/12(FM)

03/27/12(OM)test 1 test 2
3/29/12 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
3/30/12 28 29 30 31

Channel 345 dead (as on hybrid), else OK: test 31

3/31/12(OM)

?

Module T1

READY

Half-module 13

Hybrid 15t

Sensor 153

3/22/12(TKN)

3/22/12(TKN)

3/23/12(PH)

03/28/12(FM)

03/28/12(FM)

03/29/12(OM)test 1
3/30/12 test 2
3/30/12 test 3
3/30/12 test 4
3/30/12 test 5

OK: test 5

3/31/12(OM)

?

Module B4

READY

Half-module 14

Hybrid 16t

Sensor 155

3/22/12(TKN)

3/22/12(TKN)

3/23/12(PH)

03/28/12(FM)

03/28/12(FM)

3/29/12 (OM) test 1
3/30/12 test 2
3/30/12 test 3
3/30/12 test 4
3/30/12 test 5
3/30/12 test 6
3/30/12 test 7
3/30/12 test 8
04/01/12 (VF) test 9
4/1/12 test 10
4/1/12 test 11

Pedestal shift on channel 147? Else OK.
Chan. 147 has long tails in the response. Others OK.
Starting with test 9, tails in many of channels 256-319, 448-511: test 10

4/1/12 (PH)

?

Module ?

PROCESSING

Half-module 15

Hybrid 17t

Sensor 156

3/23/12(TKN)

3/23/12(TKN)

3/26/12 (AG,VF,JN)

03/29/12(FM)

03/29/12(FM)

03/29/12(OM)test 1
3/30/12test 2
3/30/12test 3
3/31/12test 4

APV0 and APV2 display a large spread in the noise, else OK
Noise looks normal on test 4: test 4

3/31/12(OM)

?

Module T5

READY

Half-module 16

Hybrid 18t

Sensor 157

3/23/12(TKN)

3/23/12(TKN)

3/26/12 (AG,VF,JN)

03/29/12(FM)

03/29/12(FM)

03/29/12(OM) test 1
3/30/12test 2
3/31/12(VF)3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

OK

3/31/12 (OM)?

?

Module ?

PROCESSING

Half-module 17

Hybrid 19t

Sensor 159

3/23/12(TKN)

3/23/12(TKN)

3/26/12 (AG,VF,JN)

03/29/12(FM)

03/29/12(FM)

3/30/12(OM) test 1
3/31/12test 2
3/31/12test 3
3/31/12test 4
3/31/12test 5
3/31/12test 6
3/31/12test 7

Channel 254 bad (as on hybrid), else OK: test 7 shows tails on ch. 48

3/31/12(OM)

?

Module B1

PROCESSING

Half-module 18

Hybrid 20t

Sensor 563

3/26/12(TKN)

3/26/12(TKN)

03/27/12(PH)

03/30/12(FM)

03/30/12(FM)

04/01/12 (VF) test 1
test 2
test 3

Channel 220 unbonded in test 1 and shows tails in test 2: test 2

4/1/12 (PH)

?

Module ?

PROCESSING

Half-module 19

Hybrid 21t

Sensor 564

3/26/12(TKN)

3/26/12(TKN)

03/27/12(PH)

03/30/12(FM)

03/30/12(FM)

04/01/12 (VF) test 1
test 2
test 3

OK: test 2

4/1/12(PH)

?

Module T4

PROCESSING

Half-module 20

Hybrid 24t

Sensor 565

3/26/12(TKN)

3/26/12(TKN)

03/27/12(PH)

03/30/12(FM)

03/30/12(FM)

04/01/12 (VF) test 1
test 2
test 3
test 4
test 5

Chan 135 and entire APV0 have long baseline distribution tails. Everything else is OK: test 3

4/1/12 (PH)

?

Module ?

PROCESSING

Half-module 21

Hybrid 5t

Sensor 144

3/27/12(TKN)

3/27/12(TKN)

03/27/12(PH)

03/30/12(FM)

03/30/12(FM)

04/01/12 (VF) test 1
test 2
test 3
test 4
test 5

For 1st 3 tests, had 4 bad channels:
tails on 402 (new),
417 (was on bare hybrid),
431 and 432 (known sensor pinholes). Others are OK: test 2

04/03/12(OM)

?

Module T2

PROCESSING

Half-module 22

Hybrid 22t

Sensor 566

3/27/12(TKN)

3/27/12(TKN)

03/30/12 (AG,VF)

04/01/12(FM)

04/01/12(FM)

04/02/12(OM)
4/2/12 test 1
4/2/12 test 2
4/2/12 test 3
4/2/12 test 4
4/2/12 test 5
4/2/12 test 6
4/2/12 test 7
4/2/12 test 8
4/2/12 test 9

Channel 180 has tails on test 1 only, else OK: test 8

04/03/12(OM)

?

Module T1

PROCESSING

Half-module 23

Hybrid 23t

Sensor 567

3/27/12(TKN)

3/27/12(TKN)

03/30/12 (AG,VF)

04/01/12(FM)

04/01/12(FM)

04/02/12(OM) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
4/5/12 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
4/6/12 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58

OK; Persistent high noise??
I don't see a problem with noise - runs 1 and 2 look fine; 3-5 have DAQ noise, and 6 has the "noise hump" (SU)
Later runs have a problem that did not seem to go away (VF)

?

?

Module ?

PROCESSING

Half-module 24

Hybrid 25t

Sensor 597

3/30/12 (TKN)

3/30/12 (TKN)

4/1/12 (PH)

04/02/12(FM)

04/02/12(FM)

04/03/12(OM)
4/3/12test 1
4/3/12test 2
4/3/12test 3
4/3/12test 4
4/3/12test 5
4/3/12test 6
4/3/12test 7

Tails on channel 170, else OK

04/03/12(OM)

?

Module B2

PROCESSING

Half-module 25

Hybrid 26t

Sensor 601

3/30/12 (TKN)

3/30/12 (TKN)

4/1/12 (PH)

04/02/12(FM)

04/02/12(FM)

04/02/12(OM) test 1

OK

04/03/12(OM)

?

Module ?

PROCESSING

Half-module 26

Hybrid 27t

Sensor 604

3/30/12 (TKN)

3/30/12 (TKN)

4/1/12 (PH)

04/03/12(FM)

04/03/12(FM)

04/04/12(VF) test 1
test 2
test 3

A calibration line on APV4 has low offsets. Everything else is OK: test 2

04/05/12(OM)

?

Module T4

PROCESSING

Half-module 27

Hybrid 30t

Sensor 603

4/1/12(TKN)

4/1/12(TKN)

4/2/12 (TKN,FM)

04/03/12(FM)

04/03/12(FM)

04/04/12(OM) test 1
test 2

Channel 622 is a pinhole (as on sensor? Sensor data says 623). Channels 203, 300-302 have long pedestal tails (as on hybrid). Else OK.

04/05/12(OM)

?

Module ?

PROCESSING

Half-module 28

Hybrid 28t

Sensor 1801

4/1/12(TKN)

4/1/12(TKN)

4/2/12 (TKN,FM)

04/03/12(FM)

04/03/12(FM)

04/04/12(OM) test 1
test 2

OK

04/05/12(OM)

?

Module B3

PROCESSING

Half-module 29

Hybrid 29t

Sensor 1802

4/1/12(TKN)

4/1/12(TKN)

4/2/12 (TKN,FM)

04/03/12(FM)

04/03/12(FM)

04/04/12(OM) test 1
test 2

Channel 608 has long tails; possibly bad. Else OK.

04/05/12(OM)

?

Module T3

PROCESSING

Test run module production

Module #

Axial half-module

Stereo half-module

Cooling plate

Assembled

Surveyed

Mounted to support plate

Part of support plate

Notes

Module T1

Half-module 12

Half-module 22

100-9

4/7/12(TKN)

4/8/12(TKN)

4/9/12(TKN)

Top support plate

?

Module T2

Half-module 21

Half-module 6

100-10

4/7/12(TKN)

4/8/12(TKN)

4/9/12(TKN)

Top support plate

?

Module T3

Half-module 29

Half-module 1

100-7

4/7/12(TKN)

4/8/12(TKN)

4/9/12(TKN)

Top support plate

?

Module T4

Half-module 19

Half-module 26

50-2

4/6/12(TKN)

4/8/12(TKN)

4/9/12(TKN)

Top support plate

?

Module T5

Half-module 15

Half-module 10

50-3

4/6/12(TKN)

4/8/12(TKN)

4/9/12(TKN)

Top support plate

?

Module B1

Half-module 4

Half-module 17

100-3

4/7/12(TKN)

4/8/12(TKN)

4/9/12(TKN)

Bottom support plate

?

Module B2

Half-module 9

Half-module 24

100-5

4/7/12(TKN)

4/8/12(TKN)

4/9/12(TKN)

Bottom support plate

?

Module B3

Half-module 3

Half-module 28

100-4

4/7/12(TKN)

4/8/12(TKN)

4/9/12(TKN)

Bottom support plate

?

Module B4

Half-module 8

Half-module 13

50-6

4/6/12(TKN)

4/8/12(TKN)

4/9/12(TKN)

Bottom support plate

?

Module B5

Half-module 7

Half-module 5

50-1

4/6/12(TKN)

4/8/12(TKN)

4/9/12(TKN)

Bottom support plate

?

  • No labels