Search/Navigation:
Related:
SLAC/EPP/HPS Public
Jefferson Lab/Hall B/HPS Run Wiki
S30XL-LESA/LDMX
Confluence will be down for maintenance June 14 2024 at 6AM PT.
Half-module ID: 12
Test number: 21
Parameter Value ICAL ISHA VFP VFS Temperature Test data: http://slac.stanford.edu/~meeg/SVT_production/half_module/12/21/data
Physical channel ordering: PDF:
Readout channel ordering: PDF:
Test results (images and numerical values): http://slac.stanford.edu/~meeg/SVT_production/half_module/12/21/plotsBaseline run
Pedestal and noise (black markers are for all samples together, colored markers are individual samples)
Sample-to-sample shift
Noise correlations
Timing calibration runs, aggregate shaping curve fits
Fit parameters (colors identify calibration groups)
Timing calibration runs, hit-by-hit fits
Linearity of fitted T0 (ideal CR-RC fit on left, spline fit on right)
Goodness of fit (ideal CR-RC fit on left, spline fit on right)
Time resolution at each calibration delay (ideal CR-RC fit - stars mark error reported by fitter, dots mark spread in distribution of fitted values)