Sensor #

Received

Tested

V dep (V)

V break (V)

Pinholes

Shorts

Opens

Glued to carbon fiber

Part of half-module

Notes

Sensor 152

7/13/11(AG)

(HPK)(UCSC)

120

600

-

-

-

3/11/14(TKN)

L4-L6 half-module 0

COMPLETE

Sensor 620

10/04/13(VF)

(HPK)(UCSC)

130

310

-

-

-

?

L4-L6 half-module ?

 

Sensor 621

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

03/27/14(TKN)

L4-L6 half-module 1

COMPLETE

Sensor 622

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

03/27/14(TKN)

L4-L6 half-module 1

COMPLETE

Sensor 623

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

04/30/14 (TKN)

L4-L6 half-module 2

 

Sensor 624

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

04/30/14 (TKN)

L4-L6 half-module 2

 

Sensor 625

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

05/06/14 (TKN)

L4-L6 half-module 3

 

Sensor 626

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

05/06/14 (TKN)

L4-L6 half-module 3

 

Sensor 627

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

05/06/14 (PH)

L4-L6 half-module 4

 

Sensor 629

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

05/06/14 (PH)

L4-L6 half-module 4

 

Sensor 630

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

05/13/14 (TKN)

L4-L6 half-module 5

 

Sensor 632

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module ?

Large surface scratch. Unclear if it's deep enough. Details to come.

Sensor 635

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

05/13/14 (TKN)

L4-L6 half-module 5

 

Sensor 637

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

05/13/14 (PH)

L4-L6 half-module 6

 

Sensor 638

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

05/13/14 (PH)

L4-L6 half-module 6

 

Sensor 640

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module 7

 

Sensor 642

10/04/13(VF)

(HPK)(UCSC)

130

880

-

-

-

?

L4-L6 half-module ?

 

Sensor 643

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module 7

 

Sensor 645

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module 8

 

Sensor 646

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module 8

 

Sensor 647

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module 9

 

Sensor 648

10/04/13(VF)

(HPK)(UCSC)

130

580

-

-

-

3/11/14(TKN)

L4-L6 half-module 0

COMPLETE

Sensor 649

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module 9

 

Sensor 650

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module ?

Observed long scratch near edge.

Sensor 652

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module 10

 

Sensor 653

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module 10

 

Sensor 654

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module ?

Observed large scuffed area near one end.

Sensor 655

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module 11

 

Sensor 656

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module 11

 

Sensor 657

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module 12

 

Sensor 658

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module 12

 

Sensor 661

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module ?

 

Sensor 662

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module ?

 

Sensor 663

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module ?

 

Sensor 664

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module ?

 

Sensor 665

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module ?

 

Sensor 666

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module ?

 

Sensor 668

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module ?

 

Sensor 669

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module ?

 

Sensor 670

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module ?

 

Sensor 671

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module ?

 

Sensor 672

10/04/13(VF)

(HPK)(UCSC)

130

>1000

-

-

-

?

L4-L6 half-module ?

 

Sensor 183008/05/14 (OM/VF)(HPK)(UCSC) >1000---?L4-L6 half-module ? 
Sensor 183108/05/14 (OM/VF)(HPK)(UCSC) 990---?L4-L6 half-module ? 
Sensor 183208/05/14 (OM/VF)(HPK)(UCSC) >1000---?L4-L6 half-module ? 
Sensor 183408/05/14 (OM/VF)(HPK)(UCSC) >1000---?L4-L6 half-module ? 
Sensor 183608/05/14 (OM/VF)(HPK)(UCSC) 860---?L4-L6 half-module ? 
Sensor 183708/05/14 (OM/VF)(HPK)(UCSC) 860---?L4-L6 half-module ? 
Sensor 183908/05/14 (OM/VF)(HPK)(UCSC) >1000---?L4-L6 half-module ? 
Sensor 184008/05/14 (OM/VF)(HPK)(UCSC) >1000---?L4-L6 half-module ? 
Sensor 184208/05/14 (OM/VF)(HPK)(UCSC) >1000---?L4-L6 half-module ? 
Sensor 184308/05/14 (OM/VF)(HPK)(UCSC) 900---?L4-L6 half-module ? 

Sensor Channel Ordering

Sensor Drawing

  • No labels