Half-module ID: 23
Test number: 58
Parameter Value ICAL ISHA VFP VFS Temperature Test data: http://slac.stanford.edu/~meeg/SVT_production/half_module/23/58/data
Physical channel ordering: PDF:
Readout channel ordering: PDF:
Test results (images and numerical values): http://slac.stanford.edu/~meeg/SVT_production/half_module/23/58/plotsBaseline run
Pedestal and noise (black markers are for all samples together, colored markers are individual samples)
Sample-to-sample shift
Noise correlations
Timing calibration runs, aggregate shaping curve fits
Fit parameters (colors identify calibration groups)
Timing calibration runs, hit-by-hit fits
Linearity of fitted T0 (ideal CR-RC fit on left, spline fit on right)
Goodness of fit (ideal CR-RC fit on left, spline fit on right)
Time resolution at each calibration delay (ideal CR-RC fit - stars mark error reported by fitter, dots mark spread in distribution of fitted values)