You are viewing an old version of this page. View the current version.
Compare with Current
View Page History
« Previous
Version 2
Next »
- EPICS IOC Prepared
- SXR IOC Configuration:
- git repo: Undulator_SXR
- git branch: epics7-update
- RELEASE_SITE:
- BASE_MODULE_VERSION=R7.0.3.1-1.0
EPICS_SITE_TOP=/afs/slac/g/lcls/epics
BASE_SITE_TOP=/afs/slac/g/lcls/epics/base
EPICS_MODULES=/afs/slac/g/lcls/epics/R7.0.3.1-1.0/modules
IOC_SITE_TOP=/afs/slac/g/lcls/epics/iocTop
PACKAGE_SITE_TOP=/afs/slac/g/lcls/package
TOOLS_SITE_TOP=/afs/slac/g/lcls/tools
ALARM_CONFIGS_TOP=/afs/slac/g/lcls/tools/AlarmConfigsTop
- SXR Test Plan-Week 1: Practice test on SXU-021
- Prepare work:
- Record current iocSpecificRelease for sioc-b81-mc03:
- iocSpecificRelease -> /u/cd/tthayer/workspace/LCLSII/SXRU/Undulator_SXR_MMF/
- During the test day:
- Boot current EPICS 3 based IOC, record settings:
- Currently sioc-b81-mc03 is running, need to check again before test
- Open EDM based Undulator GUI
- Before any movement, record all the settings.
- Take screenshots from GUI
- Follow checkout sheet to process the practice tests
- Print the checkout sheet
- According to the checkout sheet, the main motion test should be as follows:
- Tests will verify the correct operation of the following motion controls:
- Wiring, switch status, ESTOP functionality.
- Coordinated motion for gap adjustment.
- Encoder read back: available, calibrated.
- Limit, tilt, and vacuum switches: single axis, coordinated motion.
- Stop the test if encounter any issue/hazard, contact Alex for help.
- After all the test, revert all the settings as same as saved before.