Plans for the stavelets 8/21/19 (CV, PG, VC)

Goal: load heaters and measure thermal performance before and after irradiation to validate the glue adhesive choice and application

Ideally we would like to do this w and w/o araldite dots – YES

  •  3 stavelets available (with heaters scraped off)
  •  7 compatible heaters available (~quad size) + additional new heaters
  •  How many heaters per stavelet?which size? 
    •  Do we want to have 2 heathers on one side and 1 on the other?
      • This configuration would be only close to the the ring one (and not even completely), so most likely only two heathers on the same side
  •  Which fixture  for loading?
  •  Thickness SE4445 100 or 150? Both
  •  Can we measure thermal performance w/o the test box?


If we say we want to test heathers on stavelets with and without araldite, each of them with 100 and 150 um SE4445 we have

SE4445 + Araldite (100)

SE4445 + Araldite (150)

SE4445 (100)

SE4445 (150)


For a statistically meaningful test we would probably need 3 samples for each configuration, but we don't have enough stavelets.

So maybe more samples for the configuration we would like to use in the actual detector:


3x   SE4445 + Araldite (100)

3x  SE4445 + Araldite (150)

2x SE4445 (100)

2x SE4445 (150)


What about the non-perfect edges? Do we test this to somehow? Given Charlie's calculation even if ~20% of the surface is not cover by glue, we would have a 1^ difference in Temperature which the IR camera can't even detect

General question: test also with the RTDs?

 


  • No labels