Plans for the stavelets 8/21/19 (CV, PG, VC)
Goal: load heaters and measure thermal performance before and after irradiation to validate the glue adhesive choice and application
Ideally we would like to do this w and w/o araldite dots – YES
If we say we want to test heathers on stavelets with and without araldite, each of them with 100 and 150 um SE4445 we have
SE4445 + Araldite (100)
SE4445 + Araldite (150)
SE4445 (100)
SE4445 (150)
For a statistically meaningful test we would probably need 3 samples for each configuration, but we don't have enough stavelets.
So maybe more samples for the configuration we would like to use in the actual detector:
3x SE4445 + Araldite (100)
3x SE4445 + Araldite (150)
2x SE4445 (100)
2x SE4445 (150)
What about the non-perfect edges? Do we test this to somehow? Given Charlie's calculation even if ~20% of the surface is not cover by glue, we would have a 1^ difference in Temperature which the IR camera can't even detect
General question: test also with the RTDs?