HM # | run # | date | bias | temp (baseline run, #0) | notes on setup | results | notes on results |
---|---|---|---|---|---|---|---|
2 | 1 | 5/28/14 6:57 p.m. | 200 V | room T (23.2) | plots | low noise 11, 33 | |
2 | 2 | 5/29/14 10:31 a.m. | 200 V | room T (30.5) | plots | low noise 11, 33 | |
2 | 3 | 5/29/14 6:59 p.m. | 200 V | room T (26.1) | added dummy run at start of cal | plots | low noise 11, 33 |
2 | 4 | 6/2/14 12:55 p.m. | 200 V | cold (-0.8) | plots | low noise 11, 33 | |
11 | 1 | 5/19/14 7:30 p.m. | 200 V | room T (26.4) | bad clock delay | plots | low noise 183, high noise 0, 638 |
11 | 2 | 5/19/14 8:08 p.m. | 200 V | cooling down (5.2) | plots | low noise 183, high noise 0, 638 | |
11 | 3 | 5/19/14 8:26 p.m. | 200 V | cooling down (2.1) | plots | low noise 183, high noise 0, 638 | |
11 | 4 | 5/20/14 11:47 a.m. | 200 V | room T (27.7) | plots | low noise 183, high noise 0, 638 | |
11 | 5 | 5/20/14 4:29 p.m. | 200 V | room T (25.3) | R81 reworked | plots | low noise 183 |
11 | 6 | 5/20/14 5:27 p.m. | 200 V | cold (-0.4) | plots | low noise 183 | |
11 | 7 | 5/20/14 5:58 p.m. | 200 V | cold (-0.4) | removed wire between grounds | plots | low noise 183 |
11 | 8 | 5/28/14 6:28 p.m. | 200 V | cold (-0.2) | plots | low noise 183 | |
11 | 9 | 5/29/14 6:50 p.m. | 200 V | room T (26.1) | added dummy run at start of cal | plots | low noise 183 |
11 | 10 | 6/2/14 2:45 p.m. | 200 V | cold (-1.4) | plots | low noise 183 | |
14 | 1 | room T | |||||
16 | 1 | 5/29/14 11:54 a.m. | 200 V | room T (24.0) | plots | OK | |
16 | 2 | 5/29/14 6:39 p.m. | 200 V | room T (25.9) | added dummy run at start of cal | plots | OK |
16 | 3 | 6/2/14 3:45 p.m. | 200 V | cold (-0.3) | plots | OK | |
18 | 1 | 5/29/14 12:03 p.m. | 200 V | room T (23.2) | plots | OK | |
18 | 2 | 5/29/14 6:24 p.m. | 200 V | room T (25.6) | added dummy run at start of cal | plots | OK |
18 | 3 | 6/2/14 8:21 p.m. | 200 V | cold (-2.5) | plots | OK | |
20 | 1 | 5/29/14 1:31 p.m. | 200 V | room T (24.1) | plots | tails 135, 512-639 | |
20 | 2 | 5/29/14 6:15 p.m. | 200 V | room T (25.8) | added dummy run at start of cal | plots | tails 135, 512-639 |
20 | 3 | 6/2/14 4:12 p.m. | 200 V | cold (-0.3) | plots | tails 135, 512-639 | |
23 | 1 | 5/29/14 1:42 p.m. | 200 V | room T (24.5) | plots | OK | |
23 | 2 | 5/29/14 5:54 p.m. | 200 V | room T (25.8) | added dummy run at start of cal | plots | OK |
23 | 3 | 6/2/14 5:56 p.m. | 200 V | cold (1.2) | plots | OK | |
25 | 1 | 5/29/14 1:50 p.m. | 200 V | room T (24.0) | plots | OK; bad latency for one t0 run? | |
25 | 2 | 5/29/14 5:41 p.m. | 200 V | room T (24.7) | added dummy run at start of cal | plots | OK |
25 | 3 | 6/2/14 7:07 p.m. | 200 V | cold (-1.0) | plots | OK | |
27 | 1 | 5/29/14 1:59 p.m. | 200 V | room T (24.5) | plots | tails 203, 300-302, low noise 622, 625 | |
27 | 2 | 5/29/14 5:33 p.m. | 200 V | room T (23.1) | added dummy run at start of cal | plots | tails 203, 300-302, low noise 622, 625 |
27 | 3 | 6/2/14 7:47 p.m. | 200 V | cold (-2.3) | plots | no response 128-255; tails 203, 300-302, low noise 622, 625 | |
27 | 4 | cold |