HM # | run # | date | bias | temp (baseline run, #0) | notes on setup | results | notes on results |
---|---|---|---|---|---|---|---|
1 | 1 | 10/15/14 11:46 a.m. | 200 V | room T (25.6) | plots | high noise 639 | |
2 | 1 | 5/28/14 6:57 p.m. | 200 V | room T (23.2) | plots | low noise 11, 33 | |
2 | 2 | 5/29/14 10:31 a.m. | 200 V | room T (30.5) | plots | low noise 11, 33 | |
2 | 3 | 5/29/14 6:59 p.m. | 200 V | room T (26.1) | added dummy run at start of cal | plots | low noise 11, 33 |
2 | 4 | 6/2/14 12:55 p.m. | 200 V | cold (-0.8) | plots | low noise 11, 33 | |
3 | 1 | 6/13/14 12:02 p.m. | 200 V | room T (24.1) | plots | low noise/no response 627 | |
3 | 2 | 7/11/14 12:31 p.m. | 200 V | cold (-1.5) | plots | low noise/no response 627 | |
4 | 1 | 10/21/14 11:56 a.m. | 200 V | room T (25.1) | plots | low noise/no response 317, 319 | |
5 | 1 | 6/13/14 12:44 p.m. | 200 V | room T (23.2) | plots | OK | |
5 | 2 | 7/10/14 7:36 p.m. | 200 V | cold (-10.2) | plots | OK | |
6 | 1 | 10/21/14 12:44 p.m. | 200 V | room T (25.0) | plots | low noise/no response 0, low noise 134 | |
7 | 1 | 6/13/14 12:51 p.m. | 200 V | room T (24.4) | plots | incomplete cal data; low noise 30, 65 | |
8 | 1 | 6/13/14 12:58 p.m. | 200 V | room T (23.3) | plots | OK | |
8 | 2 | 7/10/14 7:44 p.m. | 200 V | cold (-11.8) | plots | incomplete run; OK | |
9 | 1 | 10/15/14 12:01 p.m. | 200 V | room T (25.6) | plots | low noise/no response 466 | |
10 | 1 | 7/3/14 3:25 p.m. | 200 V | room T (24.0) | plots | low noise/no response 382 | |
10 | 2 | 7/11/14 12:06 p.m. | 200 V | cold (-12.4) | plots | low noise/no response 382 | |
11 | 1 | 5/19/14 7:30 p.m. | 200 V | room T (26.4) | R81 not reworked; bad clock delay | plots | low noise/no response 183, high noise 0, 638 |
11 | 2 | 5/19/14 8:08 p.m. | 200 V | cooling down (5.2) | R81 not reworked | plots | low noise/no response 183, high noise 0, 638 |
11 | 3 | 5/19/14 8:26 p.m. | 200 V | cooling down (2.1) | R81 not reworked | plots | low noise/no response 183, high noise 0, 638 |
11 | 4 | 5/20/14 11:47 a.m. | 200 V | room T (27.7) | R81 not reworked | plots | low noise/no response 183, high noise 0, 638 |
11 | 5 | 5/20/14 4:29 p.m. | 200 V | room T (25.3) | R81 reworked | plots | low noise/no response 183 |
11 | 6 | 5/20/14 5:27 p.m. | 200 V | cold (-0.4) | plots | low noise/no response 183 | |
11 | 7 | 5/20/14 5:58 p.m. | 200 V | cold (-0.4) | removed wire between grounds | plots | low noise/no response 183 |
11 | 8 | 5/28/14 6:28 p.m. | 200 V | cold (-0.2) | plots | low noise/no response 183 | |
11 | 9 | 5/29/14 6:50 p.m. | 200 V | room T (26.1) | added dummy run at start of cal | plots | low noise/no response 183 |
11 | 10 | 6/2/14 2:45 p.m. | 200 V | cold (-1.4) | plots | low noise/no response 183 | |
12 | 1 | 10/15/14 12:09 p.m. | 200 V | room T (25.2) | plots | low noise/no response 345 | |
13 | 1 | 6/13/14 2:34 p.m. | 200 V | room T (25.4) | plots | high noise 638, bad cal group in t0 run | |
13 | 2 | 6/13/14 2:49 p.m. | 200 V | room T (25.2) | plots | high noise 638 | |
13 | 3 | 7/10/14 7:26 p.m. | 200 V | cold (-12.3) | plots | high noise 638 | |
14 | 1 | 6/6/14 3:26 p.m. | 200 V | room T (23.4) | R81 not reworked; bias return and AVDD ground shorted at supply | plots | tails 147 |
14 | 2 | 6/13/14 2:41 p.m. | 200 V | room T (25.1) | plots | tails 147, bad latency one t0 run | |
14 | 3 | 6/13/14 2:57 p.m. | 200 V | room T (26.1) | plots | tails 147 | |
15 | 1 | 7/3/14 4:15 p.m. | 200 V | room T (27.1) | plots | OK - noise-vs-ch looks funny | |
15 | 2 | 7/10/14 7:17 p.m. | 200 V | cold (2.7) | plots | OK - noise-vs-ch looks funny | |
16 | 1 | 5/29/14 11:54 a.m. | 200 V | room T (24.0) | plots | OK | |
16 | 2 | 5/29/14 6:39 p.m. | 200 V | room T (25.9) | added dummy run at start of cal | plots | OK |
16 | 3 | 6/2/14 3:45 p.m. | 200 V | cold (-0.3) | plots | OK | |
17 | 1 | 10/21/14 12:14 p.m. | 200 V | room T (24.1) | plots | 254 pedestal offscale high | |
18 | 1 | 5/29/14 12:03 p.m. | 200 V | room T (23.2) | plots | OK | |
18 | 2 | 5/29/14 6:24 p.m. | 200 V | room T (25.6) | added dummy run at start of cal | plots | OK |
18 | 3 | 6/2/14 8:21 p.m. | 200 V | cold (-2.5) | plots | OK | |
19 | 1 | 7/3/14 3:43 p.m. | 200 V | room T (23.4) | plots | low noise 523 | |
19 | 2 | 7/10/14 7:10 p.m. | 200 V | cold (-9.4) | plots | OK | |
19 | 3 | 10/15/14 11:34 a.m. | 200 V | room T (26.3) | plots | low noise 523 | |
20 | 1 | 5/29/14 1:31 p.m. | 200 V | room T (24.1) | plots | tails 135, 512-639 | |
20 | 2 | 5/29/14 6:15 p.m. | 200 V | room T (25.8) | added dummy run at start of cal | plots | tails 135, 512-639 |
20 | 3 | 6/2/14 4:12 p.m. | 200 V | cold (-0.3) | plots | tails 135, 512-639 | |
21 | 1 | 10/21/14 12:35 p.m. | 200 V | room T (24.7) | plots | 417 pedestal offscale high, low noise/no response 431, 432, low noise 462, 463 | |
22 | 1 | 10/15/14 12:17 p.m. | 200 V | room T (25.2) | plots | OK | |
23 | 1 | 5/29/14 1:42 p.m. | 200 V | room T (24.5) | plots | OK | |
23 | 2 | 5/29/14 5:54 p.m. | 200 V | room T (25.8) | added dummy run at start of cal | plots | OK |
23 | 3 | 6/2/14 5:56 p.m. | 200 V | cold (1.2) | plots | OK | |
24 | 1 | 10/15/14 2:13 p.m. | 200 V | room T (27.5) | plots | low noise/no response 170 | |
25 | 1 | 5/29/14 1:50 p.m. | 200 V | room T (24.0) | plots | OK; bad latency for one t0 run? | |
25 | 2 | 5/29/14 5:41 p.m. | 200 V | room T (24.7) | added dummy run at start of cal | plots | OK |
25 | 3 | 6/2/14 7:07 p.m. | 200 V | cold (-1.0) | plots | OK | |
26 | 1 | 7/3/14 3:58 p.m. | 200 V | room T (23.2) | plots | OK | |
26 | 2 | 7/10/14 6:53 p.m. | 200 V | cold (-7.3) | plots | OK | |
27 | 1 | 5/29/14 1:59 p.m. | 200 V | room T (24.5) | plots | tails 203, 300-302, low noise/no response 622, low noise 625 | |
27 | 2 | 5/29/14 5:33 p.m. | 200 V | room T (23.1) | added dummy run at start of cal | plots | tails 203, 300-302, low noise/no response 622, low noise 625 |
27 | 3 | 6/2/14 7:47 p.m. | 200 V | cold (-2.3) | plots | no response 128-255; tails 203, 300-302, low noise/no response 622, low noise 625 | |
27 | 4 | 6/3/14 3:19 p.m. | 200 V | cold (-1.9) | plots | tails 203, 300-302, low noise/no response 622, low noise 625 | |
28 | 1 | 7/3/14 4:23 p.m. | 200 V | room T (24.6) | plots | OK | |
28 | 2 | 7/10/14 7:02 p.m. | 200 V | cold (-8.2) | plots | OK | |
29 | 1 | 10/15/14 1:33 p.m. | 200 V | room T (24.9) | plots | low noise/no response 608 |