# | Test run assignment | Known issues (QA) | Other issues | Where is it? | Unpaired and cleaned | R81 rework | QA warm | QA cold | QA summary | Mounted to cooling structure | Final module (detector) assignment |
---|---|---|---|---|---|---|---|---|---|---|---|
0 | gimp! | gimped! | group C | - | |||||||
1 | T3 stereo | 81? | paired | 10/8/14 (SU) | 10/14/14 (SU) |
| high noise 639 | 10/16/14 (SU) | M4 (T3), axial | ||
2 | spare | 11, 33, 99 | paired | - | 5/28/14 (PH) | 5/29/14 (SU) | 6/2/14 (SU) | low noise 11, 33 | 10/16/14 (SU) | M5 (B1), stereo | |
3 | B3 axial | 627 | paired | 6/10/14 (SU) | 6/13/14 (PH) | 6/13/14 (SU) | 7/11/14 (SU) | low noise 627 | 10/13/14 (SU) | M8 (spare), axial | |
4 | B1 axial | 317, 319 | shipped to JLab in HM box | 10/14/14 (SU) | 10/17/14 (SU) | 10/21/14 (SU) | low noise/no response 317, 319 | ||||
5 | B5 stereo | OK | paired | 6/9/14 (SU) | 6/13/14 (PH) | 6/13/14 (SU) | 7/10/14 (SU) | OK | 10/13/14 (SU) | M3 (T2), stereo | |
6 | T2 stereo | 0, 134 | shipped to JLab in HM box | 10/14/14 (SU) | 10/17/14 (SU) | 10/21/14 (SU) | low noise/no response 0, low noise 134 | ||||
7 | B5 axial | OK | paired | 6/9/14 (SU) | 6/13/14 (PH) | 6/13/14 (SU) | low noise 30, 65 | 10/13/14 (SU) | M8 (spare), stereo | ||
8 | B4 axial | OK | paired | 6/9/14 (SU) | 6/13/14 (PH) | 6/13/14 (SU) | OK | 10/13/14 (SU) | M3 (T2), axial | ||
9 | B2 axial | 466 | paired | 10/13/14 (SU) | 10/14/14 (SU) | 10/15/14 (SU) | low noise/no response 466 | 10/21/14 (SU) | M0 (spare), axial | ||
10 | T5 stereo | OK | group C test setup | 6/10/14 (SU) | 7/3/14 (PH) | 7/3/14 (SU) | 7/11/14 (SU) | low noise 382 | |||
11 | spare | 183, 184 | Sylgard bubble | shipped to JLab in HM box | - | 5/20/14 (PH) | 5/29/14 (SU) | 5/28/14 (SU) | low noise 183 | ||
12 | T1 axial | 345 | group C test setup | 10/10/14 (SU) | 10/14/14 (SU) | 10/15/14 (SU) | low noise/no response 345 | ||||
13 | B4 stereo | OK | paired | 6/9/14 (SU) | 6/13/14 (PH) | 6/13/14 (SU) | 7/10/14 (SU) | high noise 638 | 10/16/14 (SU) | M5 (B1), axial | |
14 | spare | 147? 256-319, 448-511? | paired | - | 6/13/14 (PH) | 6/13/14 (SU) | tails 147 | 10/21/14 (SU) | M7 (spare), stereo | ||
15 | T5 axial | OK? | paired | 6/10/14 (SU) | 7/3/14 (PH) | 7/3/14 (SU) | 7/10/14 (SU) | OK - noise-vs-ch looks funny | 10/16/14 (SU) | M9 (spare), stereo | |
16 | spare | OK | paired | - | 5/28/14 (PH) | 5/29/14 (SU) | 6/2/14 (SU) | OK | 10/16/14 (SU) | M4 (T3), stereo | |
17 | B1 stereo | 48? 254 | group C test setup | 10/14/14 (SU) | 10/17/14 (SU) | 10/21/14 (SU) | 254 pedestal offscale high | ||||
18 | spare | 220? | Sylgard bubble | shipped to JLab in HM box | - | 5/28/14 (PH) | 5/29/14 (SU) | 6/2/14 (SU) | OK | ||
19 | T4 axial | OK | paired | 6/10/14 (SU) | 7/3/14 (PH) | 7/3/14 (SU) | 7/10/14 (SU) | low noise 523 in warm run, OK in cold run | 10/16/14 (SU) | M9 (spare), axial | |
20 | spare | 135, 512-639 | group C test setup | - | 5/28/14 (PH) | 5/29/14 (SU) | 6/2/14 (SU) | tails 135, 512-639 | |||
21 | T2 axial | 402, 417, 431, 432 | paired | 10/14/14 (SU) | 10/17/14 (SU) | 10/21/14 (SU) | 417 pedestal offscale high, low noise/no response 431, 432, low noise 462, 463 | 10/21/14 (SU) | M7 (spare), axial | ||
22 | T1 stereo | 180? | paired | 10/10/14 (SU) | 10/14/14 (SU) | 10/15/14 (SU) | OK | 10/16/14 (SU) | M6 (T1), stereo | ||
23 | bad | DAQ issues? | paired | - | 5/28/14 (PH) | 5/29/14 (SU) | 6/2/14 (SU) | OK | 10/13/14 (SU) | M2 (B3), stereo | |
24 | B2 stereo | 170 | paired | 10/13/14 (SU) | 10/14/14 (SU) | 10/15/14 (SU) | low noise/no response 170 | 10/21/14 (SU) | M0 (spare), stereo | ||
25 | spare | OK | paired | - | 5/28/14 (PH) | 5/29/14 (SU) | 6/2/14 (SU) | OK | 10/13/14 (SU) | M2 (B3), axial | |
26 | T4 stereo | OK | paired | 6/10/14 (SU) | 7/3/14 (PH) | 7/3/14 (SU) | 7/10/14 (SU) | OK | 10/13/14 (SU) | M1 (B2), stereo | |
27 | spare | 203, 300-302, 622 | UCSC | - | 5/28/14 (PH) | 5/29/14 (SU) | 6/3/14 (SU) | tails 203, 300-302, low noise/no response 622, low noise 625 | |||
28 | B3 stereo | OK | paired | 6/10/14 (SU) | 7/3/14 (PH) | 7/3/14 (SU) | 7/10/14 (SU) | OK | 10/13/14 (SU) | M1 (B2), axial | |
29 | T3 axial | 608? | paired | 10/8/14 (SU) | 10/14/14 (SU) | 10/15/14 (SU) | low noise/no response 608 | 10/16/14 (SU) | M6 (T1), axial |
# | Test run assignment | Known issues (QA) | Test run bad channels (svt_qa.badchannels) | bad in runs | 1351 | 1353 | 1354 | 1358 | 1359 | 1360 | Other issues |
---|---|---|---|---|---|---|---|---|---|---|---|
0 | gimp! | gimped! | |||||||||
1 | T3 stereo | 81? | 81 | ||||||||
2 | spare | 11, 33, 99 | |||||||||
3 | B3 axial | 627 | 627 | 608 | 544 | 544 | 544 | ||||
4 | B1 axial | 317, 319 | 317, 318 | ||||||||
5 | B5 stereo | OK | |||||||||
6 | T2 stereo | 0, 134 | 1, 134, 639 | ||||||||
7 | B5 axial | OK | 29, 31-33 | ||||||||
8 | B4 axial | OK | misconfigured 512-639 | ||||||||
9 | B2 axial | 466 | 27, 49, 72, 91, 125, 411, 433, 466, 529, 584, 605, 627, misconfigured 128-255 | 27, 49, 72, 91, 125, 411, 433, 466, 529, 584, 605, 627, misconfigured 128-255 | |||||||
10 | T5 stereo | OK | 381, 382 | ||||||||
11 | spare | 183, 184 | Sylgard bubble | ||||||||
12 | T1 axial | 345 | 345 | ||||||||
13 | B4 stereo | OK | |||||||||
14 | spare | 147? 256-319, 448-511? | |||||||||
15 | T5 axial | OK? | 466 | ||||||||
16 | spare | OK | |||||||||
17 | B1 stereo | 48? 254 | 254 | ||||||||
18 | spare | 220? | Sylgard bubble | ||||||||
19 | T4 axial | OK | |||||||||
20 | spare | 135, 512-639 | |||||||||
21 | T2 axial | 402, 417, 431, 432 | 417, 402, 431, 432, 461-464 | 461-464 | |||||||
22 | T1 stereo | 180? | none | ||||||||
23 | bad | DAQ issues? | |||||||||
24 | B2 stereo | 170 | 170 | no hits 384-511 | 305 | 38, 81, 302 | 38, 81, 302 | 38, 169, 329, 416, 417 | |||
25 | spare | OK | |||||||||
26 | T4 stereo | OK | |||||||||
27 | spare | 203, 300-302, 622 | |||||||||
28 | B3 stereo | OK | crappy 256-638 | crappy 256-638 | crappy 256-509 | crappy 256-608 | crappy 256-608 | ||||
29 | T3 axial | 608? | 608 | pedestal shift 384-511 |
Test run bad channels omit reflection channels (0, 32, 128, 160, 256, 288, 384, 416, 512, 544) and 638, 639.