Hybrid # |
Received |
Passive components loaded / cleaned |
Sent to UCSC |
APV25s loaded |
Wirebonded |
Tested |
Results |
Sent to SLAC |
Glued to carbon fiber |
Part of half-module |
Notes |
|
---|---|---|---|---|---|---|---|---|---|---|---|---|
10/10/11(RH) |
? |
? |
? |
? |
? |
? |
? |
? |
|
|||
10/10/11(RH) |
? |
2/1/12(PH,VF) |
2/1/12(FM) |
2/3/12(FM) |
2/14/12 OM test 1 |
? |
? |
2/23/12(TKN) |
|
|||
2/21/12(RH) |
2/22/12(RH) |
2/23/12(AG) |
2/24/12(FM) |
2/27/12(FM) |
2/29/12 OM test 1 |
? |
? |
3/1/12(TKN) |
|
|||
2/21/12(RH) |
3/5/12(RH/PH) |
3/5/12(PH) |
3/6/12(FM) |
3/7/12(FM) |
3/7/12(OM) test 1 |
OK |
3/7/12(JN) |
3/10/12(TKN) |
Needs ITT connector |
|||
2/21/12(RH) |
3/5/12(RH/PH) |
3/5/12(PH) |
3/6/12(FM) |
3/7/12(FM) |
3/7/12(OM) test 1 |
OK |
3/7/12(JN) |
3/10/12(TKN) |
Solder pad ripped (dgnd), need re-work! |
|||
2/21/12(RH) |
3/5/12(RH/PH) |
3/5/12(PH) |
3/6/12(FM) |
3/7/12(FM) |
3/7/12(OM) test 1 |
OK |
3/7/12(JN) |
3/10/12(TKN) |
Needs ITT connector |
|||
2/21/12(RH) |
3/14/12(RH/PH) |
3/14/12(PH) |
3/14/12(FM) |
3/15/12(FM) |
3/16/12 (VF, OM) |
Bad channel 210, else OK. |
3/16/12 (PH) |
? |
|
|||
2/21/12(RH) |
3/14/12(RH/PH) |
3/14/12(PH) |
3/14/12(FM) |
3/15/12(FM) |
3/15/12 (VF) |
V125, AVDD, GND shorts => no readout test |
3/16/12 (PH) |
? |
Pins re-crimped but still short on V125, needs fix! |
|||
2/21/12(RH) |
3/14/12(RH/PH) |
3/14/12(PH) |
Not loaded, loose connector wire(FM, VF) |
back to SLAC |
N/A |
N/A |
3/16/12 (PH) |
? |
|
|||
2/21/12(RH) |
3/15/12(RH/PH/TKN) |
3/16/12(PH) |
3/16/12 (FM) |
3/17/12 (FM) |
3/17/12 (TC,VF) |
OK |
3/18/12 (VF) |
3/18/12(TKN) |
|
|||
2/21/12(RH) |
3/15/12(RH/PH/TKN) |
3/16/12(PH) |
3/16/12 (FM) |
3/17/12 (FM) |
3/17/12 (TC,VF) |
APV0 defective? Could not set defaults => No test results. |
? |
? |
|
|||
2/21/12(RH) |
3/15/12(RH/PH/TKN) |
3/16/12(PH) |
3/16/12 (FM) |
3/17/12 (FM) |
3/17/12 (TC,VF) |
OK |
3/18/12 (VF) |
? |
|
|||
2/21/12(RH) |
3/15/12(RH/PH/TKN) |
3/16/12(PH) |
3/16/12 (FM) |
3/17/12 (FM) |
3/17/12 (TC,VF) |
OK |
3/18/12 (VF) |
3/18/12(TKN) |
|
|||
2/21/12(RH) |
3/15/12(RH/PH/TKN) |
3/16/12(PH) |
3/16/12 (FM) |
3/17/12 (FM) |
3/17/12 (TC,VF) |
OK |
3/18/12 (VF) |
3/18/12(TKN) |
|
|||
2/21/12(RH) |
3/15/12(RH/PH/TKN) |
3/16/12(PH) |
Not loaded, b/c of gauge mark on ASIC pad. |
N/A |
N/A |
N/A |
3/18/12 (VF) |
? |
Salvage connector? |
|||
2/21/12(RH) |
3/15/12(RH/PH/TKN) |
3/16/12(PH) |
3/19/12 (FM) |
? |
? |
? |
? |
? |
|
|||
2/21/12(RH) |
3/15/12(RH/PH/TKN) |
3/16/12(PH) |
3/19/12 (FM) |
? |
? |
? |
? |
? |
|
|||
2/21/12(RH) |
3/15/12(RH/PH/TKN) |
3/16/12(PH) |
3/19/12 (FM) |
? |
? |
? |
? |
? |
|
|||
2/21/12(RH) |
3/15/12(RH/PH/TKN) |
3/16/12(PH) |
3/19/12 (FM) |
? |
? |
? |
? |
? |
|
|||
? |
? |
? |
? |
? |
? test 1 |
? |
? |
? |
? |
|
To add a hybrid, copy the line below into the table and fill in the ?s.
|[Hybrid ?] | ? | ? | ? | ? | ? | ? [test 1|Hybrid ?, test 1]| ? | ? | ? | ? |[Half-module ?]|
The below link creates the hybrid page. Enter the hybrid ID once for each page that follows, and save the resulting page.
On the hybrid page, click the link to add a test page. Enter the hybrid ID, test number and any notes in the template when prompted. You can also edit the page to record the APV25 settings and other test conditions in the table.
The hybrid page gets created with an excerpt box for the first test; copy the wiki markup for further tests.
The production table starts with an entry for one test; add a newline inside the table to add further tests.
DAQ readout ordering translates to channels on the hybrids as follows: