This page is intended to serve as a cheat sheet documenting trigger settings for common devices.

CameraLink and PGP Cameras

N.B. Cspad numbers were determined in CXI and worked in XPP.

Febo numbers were determined in XCS.

Camera Model

Pulse Polarity

Pulse Delay

Pulse Width

comments

Adimec Opal 1000

Pos

0.0006

0.0005

Pulse width affects exposure time. 0.0001 sec is too short.

Pulnix TM-6740CL

Neg

0.0008

0.0002

Pulse width affects exposure time.

LBL FCCD

Pos

 

 

Pulse width does not affect exposure time.

Cspad

Neg

5.59092e-4

1e-5

Ryan says will change to Pos polarity during shutdown

Cspad2x2

Pos

5.58487e-4

1e-5

Critical that the "Run" trigger coming from controls evr have polarity
Pos with delay of 3.0849e-4 and non critical width of 1e-5 .
In ticks, the above delay is 36725.
N.B. the above was for the digital reset mode.  With analog reset
mode, Sven determined the required delay of 35500 ticks.  Width is
also non critical and 1e-5 is fine.  In seconds, this delay is 2.982e-4.

The DAQ TTL trigger must come after the run trigger and within 5e-4 of
it.

Febo (normal)

Pos

7.78e-4

1e-6

For normal mode, trigger width not critical

Febo (Average)

Pos

4.41e-4

1e-6

For averaging mode, trigger width not critical

IPIMB

Neg

0.000651824

5e-06

 

  • No labels