excel sheet of the expected measurements.
Loggbok location:
/sdf/home/n/nakahara/analysis/detectors/IH/epix10k_mfxx10050_20230715
...
Notes and observations from the beamtime and subsequent data analysis:
commands in hutch python:
get to hutch python from mfx-daq by typing mfx3. Commands of interest:
...
lcls.bykik_set_period(x) - drops every xth event (x=137 drops every 137 event, x=2 drops every second event)
Gain configuration settings:
Table A1. Tr_bit and pixel config file combinations required to get soecific gain mode for the ePix10 small.
...
The idea is to put scripts under scripts and scan or lowFlux ntuples/.npy files etc under scan or lowFlux. This is how I had things set up on the old psana.
Instructions to run the DAQ scripts and analysis:
Attenuator scans:
DAQ scans:
...
One can run e.g. python persistenceCheck.py -r 272 -d Epix10ka2M --maxNevents 450000 with the usual base class to analyze persistence. The script stores the mean and flux of kicked events and the immediately preceding events and also makes a dumb plot.
Check the detector configurations.:
(ana-4.0.48-py3) /sdf/group/lcls/ds/daq/current/build/pdsapp/bin/x86_64-rhel7-opt/configdb_readxtc -e ./xtc/
...