See Thermal Tests (confluence page) for links and information on the studies done so far at SLAC for Thermal Testing (and related instrumentation).
===========================================================================================================================================================
QC Test Box XY Stages
16:14 PM May 21, 2021: UNDER DEVELOPMENT
This documents the set-up and the operation of the XY stages (one for the ring and the other for the stave) in the QC test box.
Contacts: Sanha Cheong (sanha@slac.stanford.edu), Zhi Zheng (zzheng@slac.stanford.edu)
Set-up Overview
The stages are powered OpenBuilds 24V DC power supplies inside the QC test box. They are also connected via USB to the iMac (running Ubuntu) next to the QC text box and can be controlled by `OpenBuilds CONTROL` software.
Operation & Calibration Procedures
Ring Stage
USB0, Left PS
X: + is down, - is up. steps / mm = 197.04
Y: + is in, - is out. steps / mm = 57.14
Interlocks: X = [-5.21mm, 263mm] Y = [-5.18mm, 410mm]