Confluence will be unusable 23-July-2024 at 06:00 due to a Crowd upgrade.
...
Camera Model | Pulse Polarity | Pulse Delay | Pulse Width | comments |
---|---|---|---|---|
Adimec Opal 1000 | Pos | 0.0008 | 0.0002 | Pulse width affects exposure time. 0.0001 sec is too short. |
Adimec Opal 4000 | Pos | 0.0008 | 0.0002 | Maximum trigger rate is 30Hz. |
Pulnix TM-6740CL | Neg | 0.0006 | 0.0005 | Pulse width affects exposure time. |
LBL FCCD | Pos |
|
| Pulse width does not affect exposure time. 60 Hz strongly recommended. |
Cspad | Neg | 5.59092e-4 | 1e-5 | Ryan says will change to Pos polarity during shutdown |
Cspad2x2 | Pos | 5.58487e-4 | 1e-5 | Critical that the "Run" trigger coming from controls evr have polarity |
Febo (normal) | Pos | 7.78e-4 | 1e-6 | For normal mode, trigger width not critical |
Febo (Average) | Pos | 4.41e-4 | 1e-6 | For averaging mode, trigger width not critical |
IPIMB | Neg | 0.000651824 | 5e-06 |
|
...