Camera Model

Pulse Polarity

Pulse Delay

Pulse Width

comments

Adimec Opal 1000

Pos

 

 

Pulse width affects exposure time. 0.0001 sec is too short.

Pulnix TM-6740CL

Neg

 

 

Pulse width affects exposure time.

LBL FCCD

Pos

 

 

Pulse width does not affect exposure time.

Cspad

Neg

5.59092e-4

1e-5

Ryan says will change to Pos polarity during shutdown

Cspad2x2

Pos

5.59092e-4

1e-5

Critical that the "Run" trigger coming from controls evr have polarity
Pos with delay of 3.0849e-4 and non critical width of 1e-5 .
In ticks, that the above delay is 36725.

Febo (normal)

Pos

7.715e-4

1e-6

For normal mode, trigger width not critical

Febo (Average)

Pos

4.345e-4

1e-6

For averaging mode, trigger width not critical