Update on the HZZ 250 GeV +80/-30 250/fb Analysis for the 29 August 2013 SiD Meeting:
Archive of the preparation and analysis code:
subproclst-data8-delay-e250-350Gflav-4jets
flavortag-all-batch-revtx-350-4jets.xml revertex-all-batch.xml
runitallbatch2 suballbatch2 allSME250p80m30.lst ffhzzE250p80m30.lst
All difference in the LCFIPlus routines were commented out; not including these should make no difference in the output.
algoEtc.cc FlavorTag.cc flavtag.cc
Analysis code:
IsolatedHighPElectronIdentifier.java
Analysis:
- divide into 4 jet / 6 jet topologies
- apply preselection depending on topology
- train/apply TMVA's
- validate with cut table
- check remaining backgrounds
variables_id_c1.png variables_id_c2.png variables_id_c3.png
TMVA driver routine and cut-table code:
Preselection variables:
Evis<140.0: (4 Jet category) # nTrks>10 && # EvisJETS>60.0 && # PTvisJETS>5.0 && # hmass>50. && hmass<140. && # fabs(fabs(dph)-3.14159)>0.15 && # ej1>40. && # jetthrust<0.99 Evis>140: (6 jet category) # nTrks>20 && # EvisJETS<220.0 && # PTvisJETS>5.0 && # hmass>100. && hmass<150. && # fabs(fabs(dph)-3.14159)>0.05 && # ej1<130. && # jetthrust<0.99
The TMVA variables:
- Evis JETS
- Mvis JETS
- PTvis JETS
- B Likeness
- C likeness
- Number of HE Electrons
- Higgs Mass
- Z energy
- Zstr energy
- Z cos theta
- Zstr cos theta
- Z mass
- Zstr mass
- azimuthal separation of Z jets
- thrust
- Number Charged Tracks
- Number of electrons
- Number of muons
Performance of different MVA options:
[neal@localhost weights]$ grep -A 8 -i optimal- ../hzzv14-presel-v4-new-common0410results.txt --- Classifier ( #signal, #backgr.) Optimal-cut S/sqrt(S+B) NSig NBkg EffSig EffBkg -- --------------------------------------------------------------------------------------------- --- Cuts: ( 664.0744,1312202.5) -0.0050 0 0 0 0 0 --- Likelihood: ( 664.0744,1312202.5) 1.0000 0.728991 644.0848 779980.1 0.9699 0.5944 --- Fisher: ( 664.0744,1312202.5) 0.0120 1.70335 258.2099 22721.13 0.3888 0.01732 --- BDTG: ( 664.0744,1312202.5) -0.9823 1.17754 538.5353 208621.3 0.811 0.159 --- BDT: ( 664.0744,1312202.5) -0.0462 3.42709 100.6751 762.2891 0.1516 0.0005809 -- ---------------------------------------------------------------------------------------------
Combined 4-jet 6-jet performance using a cut at EvisJETS of 140 GeV to determine the preselection cuts to be used:
Cut table for BDT:
isigall= 1345.984602 isigpresel= 1460.101057 igood= 114.116455 ibad= 762.500000 intot= 77692005.984714 ipre= 876.616455 cuts__ (Cut Name ): all others 2f 4f 6f aa 1f 3f 5f q e+mu tau nu Signif. cut #0 (all ): 7.769e+07 625000 14507062 1019938 0 54073784 0 7464875 0 948 91 45 262 0.15 Delta(sig*BR) = 6.548594 +/- 0.046879 cut #1 (20.<PTvisJETS ): 1.283e+07 37500 5525512 746188 0 2968250 0 3546875 0 806 69 44 259 0.33 Delta(sig*BR) = 3.042092 +/- 0.024172 cut #2 (EvisJETS<220. ): 4.637e+06 25000 3287550 514400 0 130196 0 678875 0 608 42 41 219 0.42 Delta(sig*BR) = 2.365748 +/- 0.020248 cut #3 (50.<hmass<140. ): 3.306e+06 0 2542562 378675 0 60426 0 323875 0 536 38 35 206 0.45 Delta(sig*BR) = 2.233245 +/- 0.019503 cut #4 (||dph|-3.14159|>0.15 ): 2.772e+06 0 2083912 364150 0 57097 0 266000 0 514 36 33 202 0.47 Delta(sig*BR) = 2.120439 +/- 0.018965 cut #5 (nTrks>10 ): 1.426e+06 0 1136375 169088 0 30283 0 89875 0 466 10 19 177 0.56 Delta(sig*BR) = 1.777889 +/- 0.017994 cut #6 (jetthrust<0.99 ): 1.325e+06 0 1044700 165588 0 30033 0 84125 0 463 10 19 173 0.58 Delta(sig*BR) = 1.730704 +/- 0.017728 cut #7 (ej1>40. ): 1.313e+06 0 1035112 164625 0 29215 0 83250 0 462 10 19 173 0.58 Delta(sig*BR) = 1.725415 +/- 0.017704 cut #8 (MVA ): 8.766e+02 0 138 625 0 0 0 0 0 51 0 1 62 3.85 Delta(sig*BR) = 0.259452 +/- 0.015456
Remaining backgrounds:
$ awk '{print $3,$7,$15}' zzhpassing.dat | sort -n | uniq -c | awk '{if (NF==4) print $1*$2*$4,$0}' | sort -k 1,1 -n 1278744 1 106562 4f_sz 12.500000 1278792 1 106566 4f_sw 12.500000 1278864 1 106572 4f_sz 12.500000 1278900 1 106575 4f_zz 12.500000 1279284 1 106607 2f_z_ 12.500000 2557224 2 106551 4f_ww 12.500000 2557272 2 106553 4f_zz 12.500000 2557704 2 106571 4f_sz 12.500000 2557752 2 106573 4f_zz 12.500000 3836664 3 106574 4f_zz 12.500000 3836808 3 106578 4f_ww 12.500000 12792960 10 106608 2f_z_ 12.500000 16625856 13 106576 4f_zz 12.500000 24299556 19 106577 4f_ww 12.500000
Variable distributions without any preselection:
variables_id_c1-nopresel.png variables_id_c2-nopresel.png variables_id_c3-nopresel.png