Sensor # | Received | Tested | V dep (V) | V break (V) | Pinholes | Shorts | Opens | Glued to carbon fiber | Part of half-module | Notes |
---|---|---|---|---|---|---|---|---|---|---|
7/13/11(AG) | 110 | >1000 | - | - | - | 3/11/12(TKN/PH) | COMPLETE | |||
7/13/11(AG) | 110 | >1000 | - | - | - | 3/11/12(TKN/PH) | COMPLETE | |||
7/13/11(AG) | 110 | >1000 | - | - | - | 3/11/12(TKN/PH) | COMPLETE | |||
7/13/11(AG) | 110 | >1000 | - | - | - | 3/18/12(TKN) | COMPLETE | |||
7/13/11(AG) | 110 | 520 | - | - | - | ? | In test jig at UCSC | |||
7/13/11(AG) | 110 | >1000 | - | - | - | 3/18/12(TKN) | COMPLETE | |||
7/13/11(AG) | 110 | >1000 | - | - | - | 3/18/12(TKN) | COMPLETE | |||
7/13/11(AG) | 110 | >1000 | - | - | - | ? | COMPLETE | |||
7/13/11(AG) | 120 | >1000 | 80,106,232,240,255,371 | - | - | ? | READY | |||
7/13/11(AG) | 110 | >1000 | - | 432,433 | - | 3/27/12(TKN) | COMPLETE | |||
7/13/11(AG) | 110 | >1000 | - | - | - | ? | COMPLETE | |||
7/13/11(AG) | 110 | >1000 | - | - | - | ? | COMPLETE | |||
7/13/11(AG) | 120 | >1000 | - | - | - | 3/22/12(TKN) | COMPLETE | |||
7/13/11(AG) | 120 | >1000 | - | - | - | 3/1/12(TKN) | COMPLETE | |||
7/13/11(AG) | 120 | 600 | - | - | - | ? | MOVED to 2014 Production | |||
7/13/11(AG) | 120 | 980 | - | - | - | 3/22/12(TKN) | COMPLETE | |||
7/13/11(AG) | 110 | >1000 | - | - | - | 3/22/12(TKN) | COMPLETE | |||
7/13/11(AG) | 110 | >1000 | - | - | - | 3/23/12(TKN) | COMPLETE | |||
7/13/11(AG) | 120 | >1000 | - | - | - | 3/23/12(TKN) | COMPLETE | |||
7/13/11(AG) | 110 | >1000 | - | - | - | 3/23/12(TKN) | COMPLETE | |||
7/13/11(AG) | 130 | >1000 | - | - | - | 3/26/12(TKN) | COMPLETE | |||
7/13/11(AG) | 130 | >1000 | - | - | - | 3/26/12(TKN) | COMPLETE | |||
7/13/11(AG) | 130 | >1000 | - | - | - | 3/26/12(TKN) | COMPLETE | |||
7/13/11(AG) | 130 | >1000 | - | - | - | 3/27/12(TKN) | COMPLETE | |||
7/13/11(AG) | 130 | >1000 | - | - | - | 3/27/12(TKN) | COMPLETE | |||
7/13/11(AG) | 130 | >1000 | - | - | - | 2/23/12(TKN) | COMPLETE | |||
7/13/11(AG) | 120 | 660 | - | - | - | 3/30/12(TKN) | COMPLETE | |||
7/13/11(AG) | 130 | >1000 | - | - | - | 3/30/12(TKN) | COMPLETE | |||
7/13/11(AG) | 130 | >1000 | 623 | - | - | 4/1/12(TKN) | COMPLETE | |||
7/13/11(AG) | 130 | >1000 | - | - | - | 3/30/12(TKN) | COMPLETE | |||
2/7/11(TKN) | 150 (*) | >1000 | - | - | - | ? | Has bond feet from wirebond testing | |||
2/7/11(TKN) | 150 (*) | >1000 | - | - | - | 4/1/12(TKN) | COMPLETE | |||
2/7/11(TKN) | 150 (*) | >1000 | - | - | - | 4/1/12(TKN) | COMPLETE | |||
2/7/11(TKN) | 150 (*) | >1000 (varied after scratch) | - | - | - | ? | COMPLETE |
(*) SCIPP data on these sensors show Vfd between 132 and 135 V. The data are very similar to the HPK measurements. Seems to be a difference of definitions.
To add a sensor, copy the line below into the table and fill in the ?s.
|[Sensor ?] | ? | ? [test 1|Sensor ?, test 1]| ? | ? | ? | ? | ? | ? |[Half-module ?]|