Oracle/Sun have shut down the thor line of file servers. SLAC needs to find an alternative set of vendors. Here we investigate options and gather data.
Other Labs
- FNAL (12/12/10 source: Steve Wolbers; contact Richard Dubois)
- Nexsan Satabeast recently
- they are out to bid for a big CMS order and will share the RFP with us in Jan/Feb
- CCIN2P3 (12/13/10 source: Dominique Boutigny; contact Richard Mount)
- The solution that we have retained is a DELL Server R510 + 2
extensions MD1200 (54 TB of usable space). The cost is ~0.3 ? / GB.
The performances have been measured by our storage experts and are
suitable for dCache but may not be enough for intensive xrootd access.
I will ask Benoit to send you the quantitative results of the tests.
- The solution that we have retained is a DELL Server R510 + 2
Industry Specs
- From Stuart (12/13/10), drawn from Linux Magazine
Vendor Name Number of Rack Units Number of Drives Depth (cm) Weight JBOD or RBOD SATA? SAS? Data Direct Networks S2A 6620 4U 60 103 cm 240 lbs. with drives RBOD/JBOD Yes Yes NexSan SATABeast 4U 48 74.93 cm 179 lbs. with drives RBOD Yes Yes (with SASBeast) NexSan NXS-60BE 4U 60 NA NA JBOD Yes Yes Scalable Informatics JackRabbit JR-5 5U 48 NA NA RBOD/JBOD Yes Yes LSI Engenio 2600-HD 4U 60 100.965 cm 132 RBOD/JBOD Yes Yes