Reprocessing Task Structure and Operation

Notes on the reprocessing task structure are here. Notes on pipeline operation and monitoring are here.

Index to Reprocessings

This summary is maintained manually and is excerpted from the HistoryProcessing table in Oracle which should be considered authoritative. That table can be viewed here.

Name

Status

Purpose

task name(s)

mode

to FSSC

Data Reprocessed

EvtClass

Primary Output [1]

Start Date

Details

P310In progressRemake FT2 files with spacecraft velocity columnsP310-FT2reFT2yes

239557414 (2008-08-04) - TBD

 Pass8 FT206/20/2019Notes
P305CompletePass8 FITS production with new Philippe cuts (and new ribbon cut)P305-FITSreFT1yes

239557414 (2008-08-04) - 564939451 (2018-11-26)

 Pass8 fits411/03/2017Notes
P304CompletePass8 FITS production with new Philippe cutsP304-FITSreFT1no

246823875 - 528041808

Pass8fits49/25/2017Notes
P303CompletePass8 FITS production with new Philippe cutsP303-FITSreFT1no

246823875 - 283995399

(2008-10-27/2009-12-31)

Pass8fits49/18/2017Notes
P302CompletePass8 FITS productionP302-FITS reFT1yesall science dataPass8fits41/16/2015Notes
P301CompleteNew generation MERIT and early Pass8 evt classificationsP301-MERIT
P301-FITS 

reMERIT
reFT1 

noall science dataPass8MERIT3/28/2014Notes

P300

Complete

Full Pass8 reconstruction

P300-ROOT
P300x-FITS

doRecon
reFT1

no

all science data

Prelim Pass8

recon3,merit1
fits3

4/23/2013

Notes

 P203Complete

Public Data Release 7
Update diffrsp column in FT1

P203-FITSreFT1yesall science dataPass 7.6FT1, EXTENDEDFT12/20/2014Notes

P250

Complete

Trunc64 tests

P250-ROOT

doRecon

no

8 runs

Pass 7.6

recon1

6/9/2012

Notes

P202

Complete

Public Data Release 6 
Full Pass7 reconstruction

P202-ROOT
P202-FITS

doRecon
reFT1

yes

all science data

Pass 7.6

recon2, merit1
fits3

1/20/2012


Notes

P130

Complete

Public Data Release 5
redo diffuse response

P130-FT1

reFT1

yes

all science data

Pass7.6

fits3

1/26/2012

Notes

P121-MERIT

Complete

Evt reclassification

P121-MERIT

reClassify

no

P120 (Pass 7.3)
+ new detector model
(TEST only)

Pass7.3

merit1

1/20/2011

Notes

P120-LEO

Complete

Evt reclassification

P120-LEO-MERIT

reClassify

no

L&EO earth limb data

Pass 7.3

merit1

8/13/2010

Notes

P120

Complete

Public Data Release 4
Evt reclassification

P120-MERIT
P120-FT1

reClassify
reFT1

yes

all science data

Pass7.6

merit1
fits3

7/20/2010

Notes

P118

Complete

Public Data Release 3
DiffRsp for new P6_V11 IRFs

P118-FT1

reDiffRsp

yes

all science data

Pass6 v11

FT1 only

2/15/2011

Notes

P116

Complete

Public Data Release 2
Add 'dataclean'
event classification

P116-FT1

reFT1

yes

science data

Pass6 v3

fits2

10/1/2010

Notes

P115-LEO

Complete

Evt reclassification of P106 data

P115-LEO-MERIT
P115-LEO-FT1

reClassify
reFT1

no

L&EO earth limb data

Pass7.2

merit1

7/8/2010

Notes

P110-LEO

deleted 20101216

Evt reclassification

P110-LEO-MERIT
P110-LEO-FT1

reClassify
reFT1

no

L&EO earth limb data

Pass7.2

merit1
fits1

3/7/2010

Notes

P110

deleted 20101216

Evt reclassification

P110-MERIT
P110-FT1

reClassify
reFT1

no

science data

Pass7.2

merit1
fits1

10/20/2009

Notes

P107

Complete

Create GCR files

P107-GCR

reGCR

no

science data

Pass6

GCR

10/18/2010

Notes

P106-LEO

Complete

New calibration

P106-LEO-MERIT

doRecon

no

L&EO earth limb data

Pass6

recon1, FT1

5/11/2010
6/28/2010

Notes

P105

Complete

Public Data Release 1

P105-FT1

reFT1

yes

science data

Pass6

fits1

7/23/2009

Notes

P100

Deleted

Evt reclassification

P100-MERIT
P100-FT1

reClassify
doFT1

no

science data

Pass7.2

merit1
fits1

5/27/2009

Notes

P90

Complete

ToT correction

P90-MERIT

reClassify

no

science data

Pass6

merit1

7/30/2009

Notes

RepoTest7

Complete

Alignment fix

ReproTest7

 

no

early science data

Pass6

MERIT

9/30/2008

n/a

Notes:

1. The "Primary Output" column contains the name of the file(s) produced, or to a collection of files as specified in the following table.

Name

File Collection

fits1

FT1,LS1,LS3,ELECTRONFT1

fits2

FT1,LS1

fits3

FT1,EXTENDEDFT1,LS1,EXTENDEDLS1,ELECTRONFT1

fits4FT1,EXTENDEDFT1,LS1,EXTENDEDLS1

merit1

MERIT,FILTEREDMERIT,ELECTRONMERIT

recon1

RECON,MERIT,CAL,GCR

recon2

RECON,CAL,GCR

recon3

RECON,GCR

Useful reference: File Format Document (FFD) (look for GLAST-GS-DOC-0001)

  • No labels