status: Complete
last update: 21 July 2015
This page is a record of the configuration and execution of the P302 reprocessing project, generation FITS files from the P301 MERIT files.
Notice: there is now a JIRA for this task. Please check here for operational notes.
Pipeline tasks
- P302-FITS - This task reads new P301 MERIT and produces fits files, FT1 + LS1 + EXTENDEDFT1 + EXTENDEDLS1
Datafile names, versions and locations
Data file version numbers for this reprocessing will begin with v302.
XROOT location and file naming
Location template:
/glast/Data/Flight/Reprocess/<reprocessName>/<dataType>
Locations for P302:
/glast/Data/Flight/Reprocess/P302/ft1 /glast/Data/Flight/Reprocess/P302/extendedft1 /glast/Data/Flight/Reprocess/P302/ls1 /glast/Data/Flight/Reprocess/P302/extendedls1
File naming:
Data Type | aka | Send to FSSC | Naming template |
---|---|---|---|
EXTENDEDFT1 |
| No | gll_xp_p<procVer>_r<run#>_<version>.fit |
FT1 | LS-002 | Yes | gll_ph_p<procVer>_r<run#>_<version>.fit |
EXTENDEDLS1 |
| No | gll_xe_p<procVer>_r<run#>_<version>.fit |
LS1 | LS-001 | Yes | gll_ev_p<procVer>_r<run#>_<version>.fit |
Note: 'procVer' is a field added to the file name (and the keyword "PROC_VER" in the primary header) added to the FFD 5/12/2010. Ref: http://fermi.gsfc.nasa.gov/ssc/dev/current_documents/Science_DP_FFD_RevA.pdf
Example:
/glast/Data/Flight/Reprocess/P302/recon/r0239557414_v302_merit.root
DataCatalog location and naming
Logical directory and group template:
Data/Flight/Reprocess/<reprocessName>:<dataType>
Note that the <dataType> field (following the colon) is a DataCatalog 'group' name, and file names are of the form r<run#>.
Naming examples:
Data/Flight/Reprocess/P302:MERIT r0239557414
Data Sample
The currently defined data sample (as of 1/16/2015) for P302 reprocessing includes:
First run | 239557414 (MET), 2008-08-04 15:43:34 (UTC) |
Last run | present |
Bookkeeping
- (This page): Define ingredients of reprocessing (processing code/configuration changes)
- Processing History database: http://glast-ground.slac.stanford.edu/HistoryProcessing/HProcessingRuns.jsp?processingname=P302
- List of all reprocessings
- List of all data runs reprocessed
- Pointers to all input data files (-> dataCatalog)
- Pointers to associated task processes (-> Pipeline II status)
- Data Catalog database: http://glast-ground.slac.stanford.edu/DataCatalog/folder.jsp
- Lists of and pointers to all output data files
- Meta data associated with each output data product
P302-FITS
This task generates all desired FITS data products.
- A slightly updated task structure has been implemented for this task: the mergeClumps step is now a separate subTask which allows overriding the batch queue parameter for extra long runs. This restructuring required quite a lot of modification related to data passed between job steps (as now certain job steps are in the new subTask).
- Task stored in my github as P302-FITS
Status chronology
This task basically mirrors the P301-FITS task but updating certain packages and expanding the generated data products to include FT1 and LS1.
Please see the associated JIRA for operational notes.
- 1/27/2015 - Completed block 1, through 30 Sep 2014
Name | Files | Events | Size | Created (UTC) |
---|---|---|---|---|
EXTENDEDFT1 | 34154 | 13,822,731,339 | 1.2 TB | 21-Jan-2015 20:32:16 |
EXTENDEDLS1 | 34154 | 13,822,731,339 | 2.6 TB | 21-Jan-2015 20:32:16 |
FT1 | 34154 | 691,710,015 | 64.1 GB | 21-Jan-2015 20:32:16 |
LS1 | 34154 | 1,835,112,272 | 353.2 GB | 21-Jan-2015 20:32:16 |
- 2/17/2015 - Rerun stream 29158, Run 405333211, after Warren revises the FT2 file – which adds back the final 10 minutes of this run. (Jean Ballet found this problem.)
- 2/18/2015 - Completed block 2, through 31 Jan 2015
Name | Files | Events | Size | Created (UTC) |
---|---|---|---|---|
EXTENDEDFT1 | 36020 | 14,613,698,010 | 1.3 TB | 21-Jan-2015 20:32:16 |
EXTENDEDLS1 | 36020 | 14,613,698,010 | 2.7 TB | 21-Jan-2015 20:32:16 |
FT1 | 36020 | 740,190,525 | 68.6 GB | 21-Jan-2015 20:32:16 |
LS1 | 36020 | 1,956,141,539 | 376.5 GB | 21-Jan-2015 20:32:16 |
- 3/9/2015 - Create P302-FITS v 2.0 task. The only difference is changing evtClassDefs from 01--01--01 to 01--01–04 which updates event selection to eliminate sweep and periodic trigger events. (This was discovered by Don Horner at FSSC as duplicate (sweep) events in files transferred there a couple weeks ago.)
Begin processing entire mission once again... 3/11/2015 Reprocessing complete. New Datacatalog summary:
Name Files Events Size Created (UTC) EXTENDEDFT1 36020 14,613,584,327 1.3 TB 21-Jan-2015 20:32:16 EXTENDEDLS1 36020 14,613,504,070 2.7 TB 21-Jan-2015 20:32:16 FT1 36020 740,187,922 68.6 GB 21-Jan-2015 20:32:16 LS1 36020 1,956,117,915 376.5 GB 21-Jan-2015 20:32:16 Problem with xFT1 and xLS1 files: #evts should be identical. After studying logs, decide there must be a silent failure mode to gtmktime. Rollback and now the statistics look like this:
Name Files Events Size Created (UTC) EXTENDEDFT1 36020 14,613,589,234 1.3 TB 21-Jan-2015 20:32:16 EXTENDEDLS1 36020 14,613,589,234 2.7 TB 21-Jan-2015 20:32:16 FT1 36020 740,188,083 68.6 GB 21-Jan-2015 20:32:16 LS1 36020 1,956,127,293 376.5 GB 21-Jan-2015 20:32:16 - 04/18/2015 - Begin block 2, through 7 Apr 2015
04/19/2015 - Block 2 complete. Summary from dataCatalog:
Name Files Events Size Created (UTC) EXTENDEDFT1 37023 15,032,071,005 1.3 TB 21-Jan-2015 20:32:16 EXTENDEDLS1 37023 15,032,071,005 2.8 TB 21-Jan-2015 20:32:16 FT1 37023 763,368,036 70.7 GB 21-Jan-2015 20:32:16 LS1 37023 2,015,775,627 388.0 GB 21-Jan-2015 20:32:16
06/11/2015 - Block 3, 7-Apr through 3-Jun-2015 complete (MERIT statistics from P301-MERIT task)
Name Files Events Size Created (UTC) MERIT 37888 82,148,825,606 139.7 TB 28-Mar-2014 22:40:39 EXTENDEDFT1 37888 15,381,147,951 1.4 TB 21-Jan-2015 20:32:16 EXTENDEDLS1 37888 15,381,147,951 2.9 TB 21-Jan-2015 20:32:16 FT1 37888 779,586,312 72.2 GB 21-Jan-2015 20:32:16 LS1 37888 2,059,797,732 396.4 GB 21-Jan-2015 20:32:16 - 6/27/2015 - Block 4, through 24 June 2015 FINAL block for Pass8!!
- 8/5/2015 - Block 5, an emergency reprocess of 40 runs in the period 7/27-7/30/2015 which suffered bad CAL calibrations.
Configuration
Task Location | /nfs/farm/g/glast/u38/Reprocess-tasks/P302-FITS |
Task Status | complete |
Input Data | MERIT (direct from P301-MERIT task) |
spacecraft data | P203 (released 3 June 2014) |
Input Run List | ftp://ftp-glast.slac.stanford.edu/glast.u38/Reprocess-tasks/P302-FITS/config/runList.txt |
evtClassDefs | 01-01-01 (version 1.1), 01-01-04 (version 2.0) |
eventClassMap | EvtClassDefs_P8R2.xml |
ScienceTools | 09-35-02 (1/26/2015) |
Code Variants | redhat6-x86_64-64bit-gcc44 (Optimized) |
Diffuse Model | N/A |
Diffuse Response | N/A |
IRFs | N/A |
Output Data Products | |
commonTools | 00-02-01 |
Generation of output data products:
Data Product | destination | data content [1] | event selection [1] | makeFT1 | gtselect | gtdiffrsp | gtmktime | Notes |
---|---|---|---|---|---|---|---|---|
EXTENDEDFT1 | SLAC | pass8.2_Extended_cuts_L1 | pass8.2_Transient_cuts_L1 | |||||
FT1 | FSSC | pass8_FT1variables | evclass=128 | produced from extendedFT1 | ||||
EXTENDEDLS1 | SLAC | pass8.2_Extended_cuts_L1 | pass8.2_Transient_cuts_L1 | |||||
LS1 | FSSC | pass8_LS1variables | evclass=65544 | produced from extendedLS1 |
[1] /afs/slac/g/glast/ground/releases/volume04/evtClassDefs/01-01-04/data
Note on 'Code Variant': The SLAC batch farm contains a mixture of architectures , both hardware (Intel/AMD 64-bit) and software (RHEL5-64, gcc v4.1, etc.). At this time, GlastRelease builds only on RHEL5-32 (RHEL6-64 are built but not yet validated), while ScienceTools builds for RHEL5-64, RHEL6-64.
Timing and Scaling
Approx 20 CPU minutes and 30 wall clock minutes per job (run).