status: Complete
last update: 27 June 2015

This page is a record of the configuration and execution of the P301 reprocessing project, regeneration of MERIT and FITS files from the P300 MERIT using TMine.

Notice: there is now a JIRA for this task.  Please check here for operational notes.
Pipeline tasks
  • P301-MERIT - This task reads P300 MERIT and produces reprocessed MERIT.  This is the first time TMineExt has been used to perform this function.
  • P301-FITS - This task reads new P301 MERIT and produces fits files, EXTENDEDFT1 + EXTENDEDLS1 ** THIS TASK IS DEFUNCT, see P302-FITS **

Datafile names, versions and locations

Data file version numbers for this reprocessing will begin with v300.

XROOT location and file naming

Location template:

/glast/Data/Flight/Reprocess/<reprocessName>/<dataType>

Locations for P301:

/glast/Data/Flight/Reprocess/P301/merit

[soon]
/glast/Data/Flight/Reprocess/P301/ft1
/glast/Data/Flight/Reprocess/P301/extendedft1
/glast/Data/Flight/Reprocess/P301/electronft1
/glast/Data/Flight/Reprocess/P301/ls1
/glast/Data/Flight/Reprocess/P301/extendedls1

File naming:

Data Type

aka

Send to FSSC

Naming template

MERIT

 

No

r<run#>_<version>_<dataType>.root

FILTEREDMERIT

 

No

r<run#>_<version>_<dataType>.root

ELECTRONMERIT

 

No

r<run#>_<version>_<dataType>.root

ELECTRONFT1

 

No

gll_el_p<procVer>_r<run#>_<version>.fit

EXTENDEDFT1

 

No

gll_xp_p<procVer>_r<run#>_<version>.fit

FT1

LS-002

Yes

gll_ph_p<procVer>_r<run#>_<version>.fit

EXTENDEDLS1

 

No

gll_xe_p<procVer>_r<run#>_<version>.fit

LS1

LS-001

Yes

gll_ev_p<procVer>_r<run#>_<version>.fit

Note: 'procVer' is a field added to the file name (and the keyword "PROC_VER" in the primary header) added to the FFD 5/12/2010. Ref: http://fermi.gsfc.nasa.gov/ssc/dev/current_documents/Science_DP_FFD_RevA.pdf

Example:

/glast/Data/Flight/Reprocess/P301/recon/r0239557414_v301_merit.root
DataCatalog location and naming

Logical directory and group template:

Data/Flight/Reprocess/<reprocessName>:<dataType>

Note that the <dataType> field (following the colon) is a DataCatalog 'group' name, and file names are of the form r<run#>.

Naming examples:

Data/Flight/Reprocess/P301:MERIT r0239557414

Data Sample

The currently defined data sample (as of 4/18/2014) for P301 reprocessing includes:

First run

239557414 (MET), 2008-08-04 15:43:34 (UTC)

Last run

present

Bookkeeping

  1. (This page): Define ingredients of reprocessing (processing code/configuration changes)
  2. Processing History database: http://glast-ground.slac.stanford.edu/HistoryProcessing/HProcessingRuns.jsp?processingname=P301
    1. List of all reprocessings
    2. List of all data runs reprocessed
    3. Pointers to all input data files (-> dataCatalog)
    4. Pointers to associated task processes (-> Pipeline II status)
  3. Data Catalog database: http://glast-ground.slac.stanford.edu/DataCatalog/folder.jsp
    1. Lists of and pointers to all output data files
    2. Meta data associated with each output data product

P301-MERIT

Status chronology

  • 3/27/2014 - Begin setting up P301 task for Pass8 re-MERIT.
  • 5/5/2014 - Please see the P301 JIRA for future chronology updates
  • 6/9/2014 - Begin block 2, through end of April 2014 (see JIRA)
  • 6/10/2014 - Block 2 complete
  • 10/21/2014 - Begin block 3, through end of September 2014 (see JIRA)
  • 10/22/2014 - Block 3 complete
  • 02/17/2014 - Begin block 4, through end of February 2015
  • 02/18/2015 - Block 4 complete
  • 04/16/2015 - Begin block 5, through 7 Apr 2015
  • 04/18/2015 - Block 5 complete
  • 06/11/2015 - Block 6 through 3 Jun 2015 started and completed.
  • 06/26/2015 - Block 7 - the final block - through 24 June 2015 started.
  • 06/27/2015 - Finished with Engines.
  • 08/05/2015 - Emergency reprocessing of 40 runs that suffered bad CAL calibrations. (See P300-ROOT for details.)

Configuration

Task Location

/nfs/farm/g/glast/u38/Reprocess-tasks/P301-MERIT

Task Status

http://glast-ground.slac.stanford.edu/Pipeline-II/index.jsp

TMineExt

3.3.8 (17 Apr 2014) as used from $GLAST_EXT/TMineExt

Classification worksheetv0r16 from $GLAST_EXT/extFiles

Run Selection

All MERIT files produced by P300-ROOT task

s/c data

P202 FT2SECONDS which will eventually become a "standard" Public Release https://confluence.slac.stanford.edu/display/SCIGRPS/Official+LAT+Datasets

Input Run List

ftp://ftp-glast.slac.stanford.edu/glast.u38/Reprocess-tasks/P301-MERIT/config/runList.txt

Code Variants used

redhat5-i686-32bit-gcc41, redhat5-x86_64-64bit-gcc41, redhat6-x86_64-64bit-gcc44 (Optimized)

Output Data Products

MERIT

Timing and Scaling

  • job step

    average CPU time

    TMine

    ~0.5-1M evts/hour

P301-FITS

This task generates all desired FITS data products.

  • A slightly updated task structure has been implemented for this task: the mergeClumps step is now a separate subTask which allows overriding the batch queue parameter for extra long runs.  This restructuring required quite a lot of modification related to data passed between job steps (as now certain job steps are in the new subTask). 
  • Task stored in my github as P301-FITS

 

Status chronology

This task basically mirrors the P301-MERIT task, running after the aforementioned completes

Please see the associated JIRA for operational notes.

 

Configuration

Task Location

/nfs/farm/g/glast/u38/Reprocess-tasks/P301-FITS

Task Status

http://glast-ground.slac.stanford.edu/Pipeline-II/exp/Fermi/task.jsp?refreshRate=60&task=137594093

Input Data

MERIT (direct from P301-MERIT task)

spacecraft data

same as P301-MERIT

Input Run List

ftp://ftp-glast.slac.stanford.edu/glast.u38/Reprocess-tasks/P301-FITS/config/runList.txt

evtClassDefs

01-00-01

eventClassMap

EvtClassDefs_P8V1.xml

ScienceTools

09-33-01 (5/15/2014)

Code Variants

redhat5-x86_64-64bit-gcc41 & redhat6-x86_64-64bit-gcc44   (Optimized)

Diffuse Model

N/A

Diffuse Response

N/A

IRFs

N/A

Output Data Products

EXTENDEDFT1, EXTENDEDLS1

commonTools00-02-01

Generation of output data products:

Data Product

destination

data content [1]

event selection [1]

makeFT1

gtselect

gtdiffrsp

gtmktime

EXTENDEDFT1

SLAC

pass8_FT1variables

pass8.1_Transient_cuts_L1

(tick)

(error)

(error)

(tick)

EXTENDEDLS1

SLAC

pass8_LS1variables

pass8.1_Transient_cuts_L1

(tick)

(error)

(error)

(tick)

[1] /afs/slac/g/glast/ground/releases/volume04/evtClassDefs/01-00-01/data

Note on 'Code Variant': The SLAC batch farm contains a mixture of architectures , both hardware (Intel/AMD 64-bit) and software (RHEL5-64, gcc v4.1, etc.). At this time, GlastRelease builds only on RHEL5-32 (RHEL6-64 are built but not yet validated), while ScienceTools builds for RHEL5-64, RHEL6-64.

Timing and Scaling

Approx 20 CPU minutes and 30 wall clock minutes per job (run).

 