Go back to CSPAD Alignment
Content
Optical measurement
We use before-run4 optical measuremens from Chris K.:
History of DS1 quads alignment
- 2011-10-18 CxiDs1.0:Cspad.0 cxi37411 alignment - copy of cxi35711, test runs 39, 80.
- Deployed: /reg/d/psdm/CXI/cxi37411/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/
- 2012-01-18 CSPad CxiDs1 alignment for cxi80410-r1150, cxi43312, cxi39912, etc.
Local: ~dubrovin/LCLS/CSPadAlignment-v01/calib-cxi80410-r1150-Ds1/
Deployed: /reg/d/psdm/CXI/cxi80410/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/ Files added as 1142-end.data
/reg/d/psdm/CXI/cxi43312/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/ 0-end.data - 2012-02-17 CSPad CxiDs1 alignment for cxi39112-r0009, cxi39112
Local: ~dubrovin/LCLS/CSPadAlignment-v01/calib-cxi39112-r0009-Ds1/
Deployed: /reg/d/psdm/CXI/cxi39112/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/ - 2012-03-08 CSPad CxiDs1 alignment for cxi49812-r0073 - copy of cxi37411, test runs 72(dark) 73(water ring) from 2011-12-03.
Local: ~dubrovin/LCLS/CSPadAlignment-v01/calib-cxi49812-r0073-Ds1/
Deployed: /reg/d/psdm/CXI/cxi49812/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/ - 2012-03-14 CSPad CxiDs1 alignment for cxi49012-r0020
Local: ~dubrovin/LCLS/CSPadAlignment-v01/calib-cxi49012-r0020-Ds1/*/0-end.data
Deployed: /reg/d/psdm/CXI/cxi49012/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/*/0-end.data - 2013-01-31 CSPad CxiDs1 alignment
Local: ~dubrovin/LCLS/CSPadAlignment-v01/calib-cxi64813-r0058-Ds1/*/0-end.data
Deployed: /reg/d/psdm/cxi/cxi64813/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/*/0-end.data
2016-03-16 Geometry re-alignment
- Chuck requested geometry file for old experiment cxi40112, run 23 - dark, run 32-35 - images.
Quality check
Raw metrology
Original metrology file has problems in 3 points.
CalibManager.GUIMetrology: Quality check in X-Y plane:
segm: S1 S2 dS1 dS2 L1 L2 dL1 dL2 angle(deg) D1 D2 dD d(dS) d(dL)
Quad 2
segm: 6 -20901 -20905 -123 -127 -43278 -43388 54 -56 -0.16528 48166 48056 110 4 110
segm: 7 -20893 -20902 75 66 -43465 -44415 984 34 0.09193 48166 49146 -980 9 950
Quad 3
segm: 5 20768 20906 -68 70 -43404 -43542 166 28 -0.00132 48121 48295 -174 -138 138
- Problematic measurements are
- Quad 2, segm 6. Correction for point 32 Y=130->20
- Quad 2, segm 7. Correction for point 26 Y=44485->43535
- Quad 3, segm 5. Correction for point 23 X=90854->90716 and Y=90729->90867
Corrected metrology
2016-03-16 17:09:06 (info) CalibManager.GUIMetrology: Quality check in X-Y plane:
segm: S1 S2 dS1 dS2 L1 L2 dL1 dL2 angle(deg) D1 D2 dD d(dS) d(dL)
Quad 0
segm: 0 -20911 -20907 -259 -255 43539 43543 -130 -126 -0.33818 48297 48306 -9 -4 -4
segm: 1 -20907 -20905 0 2 43535 43536 -4 -3 0.00132 48291 48298 -7 -2 -1
segm: 2 -20909 -20905 237 241 -43539 -43537 -114 -112 0.31452 48296 48299 -3 -4 -2
segm: 3 -20903 -20894 -31 -22 -43542 -43540 8 10 -0.03487 48300 48293 7 -9 -2
segm: 4 20908 20906 -111 -113 -43539 -43543 -51 -55 0.14738 48299 48301 -2 2 4
segm: 5 20911 20899 -54 -66 -43545 -43533 -35 -23 0.07896 48297 48297 0 12 -12
segm: 6 -20911 -20908 -167 -164 -43538 -43544 80 74 -0.21778 48303 48299 4 -3 6
segm: 7 -20897 -20905 -75 -83 -43539 -43541 40 38 -0.10396 48295 48297 -2 8 2
Quad 1
segm: 0 -20907 -20911 -205 -209 43544 43542 -100 -102 -0.27238 48302 48305 -3 4 2
segm: 1 -20904 -20892 -8 4 43544 43550 0 6 -0.00263 48305 48298 7 -12 -6
segm: 2 -21379 -21372 16 23 -43909 -43903 -7 -1 0.02545 48827 48837 -10 -7 -6
segm: 3 -21382 -21379 22 25 -43909 -43908 -12 -11 0.03066 48837 48837 0 -3 -1
segm: 4 20906 20915 23 32 -43535 -43543 15 7 -0.03619 48302 48298 4 -9 8
segm: 5 20911 20908 -17 -20 -43540 -43541 -11 -12 0.02434 48303 48298 5 3 1
segm: 6 -20900 -20904 63 59 -43540 -43538 -30 -28 0.08027 48296 48296 0 4 -2
segm: 7 -20900 -20901 115 114 -43537 -43543 -47 -53 0.15067 48292 48301 -9 1 6
Quad 2
segm: 0 -20910 -20905 -39 -34 43548 43540 -12 -20 -0.04803 48304 48301 3 -5 8
segm: 1 -20908 -20896 -9 3 43537 43539 0 2 -0.00395 48297 48293 4 -12 -2
segm: 2 -20900 -20912 92 80 -43536 -43536 -43 -43 0.11318 48297 48293 4 12 0
segm: 3 -20908 -20906 -61 -59 -43542 -43539 28 31 -0.07896 48299 48300 -1 -2 -3
segm: 4 20903 20900 276 273 -43538 -43536 137 139 -0.36124 48289 48300 -11 3 -2
segm: 5 20899 20895 244 240 -43538 -43540 116 114 -0.31846 48295 48293 2 4 2
segm: 6 -20901 -20905 -123 -127 -43388 -43388 54 54 -0.16507 48166 48155 11 4 0
segm: 7 -20893 -20902 75 66 -43465 -43465 34 34 0.09293 48166 48288 -122 9 0
Quad 3
segm: 0 -20904 -20897 91 98 43536 43538 42 44 0.12436 48291 48296 -5 -7 -2
segm: 1 -20909 -20904 -1 4 43529 43534 -5 0 0.00197 48288 48294 -6 -5 -5
segm: 2 -20907 -20902 338 343 -43537 -43540 -159 -162 0.44808 48295 48301 -6 -5 3
segm: 3 -20896 -20904 200 192 -43537 -43539 -95 -97 0.25793 48296 48293 3 8 2
segm: 4 20908 20906 138 136 -43533 -43542 70 61 -0.18029 48297 48297 0 2 9
segm: 5 20906 20906 -68 -68 -43404 -43404 28 28 0.08976 48121 48231 -110 0 0
segm: 6 -20900 -20905 251 246 -43540 -43541 -118 -119 0.32700 48297 48299 -2 5 1
segm: 7 -20905 -20908 248 245 -43536 -43540 -117 -121 0.32439 48298 48297 1 3 4
- Corrected metrology have consistent size of 2x1 sides, but still in 2 of corrected points the difference in diagonal is about 1 pixel size (122, 110um)...
- All other measurements are consistent with each other within
about 10um
. - Angles of 2x1 are in the range from
-0.36
to +0.44
degree.
2016-03-16 17:09:06 (info) CalibManager.GUIMetrology: Quality check in Z:
segm: SA LA XSize YSize dZS1 dZS2 dZL1 dZL2 dZSA dZLA ddZS ddZL dZX dZY angXZ(deg) angYZ(deg) dz3(um)
Quad 0
segm: 0 -20909 43541 43541 20909 3 -13 -41 -57 -5 -49 16 16 -49 -5 -0.06448 -0.01370 -15.994
segm: 1 -20906 43535 43535 20906 -19 22 -14 27 1 6 -41 -41 6 1 0.00790 0.00274 40.998
segm: 2 -20907 -43538 20907 43538 -8 -7 2 3 -7 2 -1 -1 -7 2 -0.01918 0.00263 -0.999
segm: 3 -20898 -43541 20898 43541 22 0 9 -13 11 -2 22 22 11 -2 0.03016 -0.00263 22.001
segm: 4 20907 -43541 43541 20907 -23 0 -31 -8 -11 -19 -23 -23 -19 -11 -0.02500 -0.03015 23.003
segm: 5 20905 -43539 43539 20905 10 19 -34 -25 14 -29 -9 -9 -29 14 -0.03816 0.03837 9.002
segm: 6 -20909 -43541 20909 43541 -24 -25 16 15 -24 15 1 1 -24 15 -0.06577 0.01974 1.006
segm: 7 -20901 -43540 20901 43540 4 -5 14 5 0 9 9 9 0 9 0.00000 0.01184 8.998
Quad 1
segm: 0 -20909 43543 43543 20909 -24 -6 56 74 -15 65 -18 -18 65 -15 0.08553 -0.04110 18.008
segm: 1 -20898 43547 43547 20898 -16 31 39 86 7 62 -47 -47 62 7 0.08157 0.01919 46.979
segm: 2 -21375 -43906 21375 43906 -46 -50 9 5 -48 7 4 4 -48 7 -0.12866 0.00913 4.016
segm: 3 -21380 -43908 21380 43908 -26 -10 -16 0 -18 -8 -16 -16 -18 -8 -0.04824 -0.01044 -15.999
segm: 4 20910 -43539 43539 20910 -7 -18 -53 -64 -12 -58 11 11 -58 -12 -0.07633 -0.03288 -10.983
segm: 5 20909 -43540 43540 20909 4 10 -73 -67 7 -70 -6 -6 -70 7 -0.09212 0.01918 6.003
segm: 6 -20902 -43539 20902 43539 -30 -27 21 24 -28 22 -3 -3 -28 22 -0.07675 0.02895 -3.006
segm: 7 -20900 -43540 20900 43540 -36 -14 13 35 -25 24 -22 -22 -25 24 -0.06854 0.03158 -21.996
Quad 2
segm: 0 -20907 43544 43544 20907 -9 1 6 16 -4 11 -10 -10 11 -4 0.01447 -0.01096 10.001
segm: 1 -20902 43538 43538 20902 -15 22 14 51 3 32 -37 -37 32 3 0.04211 0.00822 36.989
segm: 2 -20906 -43536 20906 43536 5 -19 15 -9 -7 3 24 24 -7 3 -0.01918 0.00395 23.989
segm: 3 -20907 -43540 20907 43540 17 14 4 1 15 2 3 3 15 2 0.04111 0.00263 2.999
segm: 4 20901 -43537 43537 20901 -23 -25 -27 -29 -24 -28 2 2 -28 -24 -0.03685 -0.06579 -2.005
segm: 5 20897 -43539 43539 20897 -2 6 -37 -29 2 -33 -8 -8 -33 2 -0.04343 0.00548 8.003
segm: 6 -20903 -43388 20903 43388 -31 -10 51 72 -20 61 -21 -21 -20 61 -0.05482 0.08055 -21.002
segm: 7 -20897 -43465 20897 43465 -10 -12 52 50 -11 51 2 2 -11 51 -0.03016 0.06723 1.995
Quad 3
segm: 0 -20900 43537 43537 20900 2 -13 17 2 -5 9 15 15 9 -5 0.01184 -0.01371 -14.999
segm: 1 -20906 43531 43531 20906 -7 32 20 59 12 39 -39 -39 39 12 0.05133 0.03289 38.992
segm: 2 -20904 -43538 20904 43538 -6 -22 14 -2 -14 6 16 16 -14 6 -0.03837 0.00790 16.005
segm: 3 -20900 -43538 20900 43538 2 4 16 18 3 17 -2 -2 3 17 0.00822 0.02237 -1.998
segm: 4 20907 -43537 43537 20907 -28 -24 -36 -32 -26 -34 -4 -4 -34 -26 -0.04474 -0.07125 4.005
segm: 5 20906 -43404 43404 20906 13 3 -26 -36 8 -31 10 10 -31 8 -0.04092 0.02193 -10.000
segm: 6 -20902 -43540 20902 43540 -44 -17 27 54 -30 40 -27 -27 -30 40 -0.08223 0.05264 -27.003
segm: 7 -20906 -43538 20906 43538 2 -11 30 17 -4 23 13 13 -4 23 -0.01096 0.03027 13.000
Alignment of quads
cxi40112, run 23 - dark, run 32,35,53 - images of rings with wires
![](/download/thumbnails/105055471/img-max-00.png?version=1&modificationDate=1458322414000&api=v2)
![](/download/thumbnails/105055471/img-max-04.png?version=1&modificationDate=1458322415000&api=v2)
![](/download/thumbnails/105055471/img-max-01.png?version=1&modificationDate=1458322414000&api=v2)
![](/download/thumbnails/105055471/img-max-02.png?version=1&modificationDate=1458322415000&api=v2)
![](/download/thumbnails/105055471/h-rad-max-02.png?version=1&modificationDate=1458322412000&api=v2)
![](/download/thumbnails/105055471/h-spe-max.png?version=1&modificationDate=1458322414000&api=v2)
Deployment
in archive:
/reg/g/psdm/detector/alignment/cspad/calib-cxi-ds1-2011-06-20/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/geometry/0-end.data
and in experimental calib directory:
/reg/d/psdm/cxi/cxi40112/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/geometry/0-end.data
References