EPICS PV Name |
Purpose |
Units |
Range |
Klystron : Area : Position : Attribute |
|
|
|
KLYS_LLRF:IN20:801:G_L0B_P |
RF Phase control |
Deg. |
|
KLYS_LLRF:IN20:801:G_LOB_P_MON |
Readback; actual value of phase |
V |
|
KLYS_LLRF:LI21:101:G_L1S_A |
RF Amplitude control |
% |
-5% to 5% |
KLYS_LLRF:LI21:101:G_L1S_A_MON |
Readback; actual value of ampl |
V |
|
KLYS_LLRF:LI21:101:G_L1S_P |
RF Phase control |
Deg. |
|
KLYS_LLRF:LI21:101:G_L1S_P_MON |
Readback; actual value of phase |
Deg. |
|
Bunch Length Monitor PVs |
EPICS PV Name |
Purpose |
Units |
Range |
Bunch Length Monitor : Area : Position : Attribute |
|
|
|
BLEN:LI21:265:WIDTH |
Width of pulse (bunch length) |
Fsec |
100.0 to 300.0 |
BPM PVs |
EPICS PV Name |
Purpose |
Units |
Range |
BPM : Area : Position : Attribute |
|
|
|
BPMS:IN20:<position>:<attribute> position = 211, 235,371,425, 511,525, 581, 631, 651, 731, 771, 781, 925, 945, 981 |
|
|
|
BPMS:LI21:<position>:<attribute> position = 131,161,201,233,278, 301,315,401, 501,601,701,801,901 |
|
|
|
|
|
|
|
Most commonly used Attributes: |
|
|
|
BPMS:<area>:<position>X |
beam position in X |
Mm |
-3.0 to 3.0 |
BPMS:<area>:<position>:Y |
beam position in Y |
Mm |
-3.0 to 3.0 |
BPMS:<area><position>:TMIT |
Electron count, charge? |
|
1e10 to 3e10 |
BPMS:<area>:<position>:XHST |
array of last 500 X measurements |
|
|
BPMS:<area>:<position>:YHST |
array of last 500 Y measurements |
|
|
BPMS:<area>:<position>:TMITHST |
array of last 500 TMIT measurements |
|
|
Toroid PVs |
EPICS PV Name |
Purpose |
Units |
Range |
Toroid : Area : Position : Attribute |
|
|
|
TORO:IN20:215:TMIT position=215, 431, 791, 971 |
Electron count, charge? |
|
1e10 to 3e10 |
TORO:LI21:205:TMIT position=205, 277 |
Electron count |
|
1e10 to 3e10 |
Wire PVs |
EPICS PV Name |
Purpose |
Units |
Range |
WIRE : Area : Position : Attribute |
|
|
|
WIRE:IN20:531:<Attribute> Position=521, 561, 611, 741 |
|
|
|
|
|
|
|
Most commonly used Attributes: |
|
|
|
WIRE:IN20:<Position>:YDATARAW |
Array of y measured raw data |
numeric |
|
WIRE:IN20:<Position>:XDATARAW |
Array of x measured raw data |
numeric |
|
WIRE:IN20:<Position>:UDATARAW |
Array of u measured raw data |
numeric |
|
WIRE:IN20:<Position>:<Y,X,U>DATA |
Plane arrays of processed data |
numeric |
|
WIRE:IN20:<Position>:<Y,X,U>SIGMA |
Plane calculated beam width |
numeric |
|
WIRE:IN20:<Position>:<Y,X,U>RMSERR |
Plane RMS error |
numeric |
|
WIRE:IN20:<Position>:<Y,X,U>FWHM |
Plane full width at half maximum height |
numeric |
|
WIRE:IN20:<Position>:<Y,X,U>MEAN |
Plane mean |
numeric |
|
WIRE:IN20:<Position>:<Y,X,U>ASYM |
Plane asymmetry |
numeric |
|
WIRE:IN20:<Position>:<Y,X,U>WIDTH |
Plane width |
numeric |
|
WIRE:IN20:<Position>:<Y,X,U>AREA |
Plane area |
numeric |
|
OTR PVs |
EPICS PV Name |
Purpose |
Units |
Range |
OTR : Area : Position : Attribute |
|
|
|
OTRS:IN20:<position>:<attribute> position = 466, 471, 541, 571, 621, 711, 991 |
|
|
|
OTRS:LI20:<position>:<attribute> position = 237, 291 |
|
|
|
YAG PVs |
EPICS PV Name |
Purpose |
Units |
Range
YAG : Area : Position : Attribute |
|
|