Blog from March, 2010

FA-GSW Report DOY 89 (March 30, 2010)

Flare-Advocate/Gamma-ray-Sky-Watcher report: DOY 89 (March 30, 2010)

On Duty Flare Advocates:

FA: Eric Wallace (wallacee@uw.edu)

Highlights

Extragalactic Science

  • PKS 0426-380 detected at flux (0.6 +/- 0.2)*10^-6 ph/cm^2/s
  • PKS 0537-441 detected at flux (1.1 +/- 0.3)*10^-6
  • 4C +21.35 at (0.8 +/- 0.2)*10^-6
  • 3C 454.3 at (7.0 +/- 0.8)*10^-6

Galactic Science

  • LS I+61 303, typical pulsars, typical fluxes
  • 2 ASP sources listed as UNID probably associated with 1FGL sources; both low TS in confused regions.

Technical notes

  • Fluxes are given in units of ph × cm^?2^ s^?1^ in the 0.1 ÷ 300 GeV energy band.
  • Science Tools: v9r15p6
  • Results are obtained with unbinned likelihood using iLat and the new FA-dedicated package,
    fareport, with its four scripts: jobs.py, day.py, six.py and wiki.py
  • IRF used : P6_V3_DIFFUSE

Likelihood Analysis results:

Daily Run (n. 00644)

Extragalactic Sources

RA(J2000)

DEC(J2000)

L

B

TS

Npred

Flux¤

Flux err¤

index

index err

Delta

1FGL

Type

Associations

ASPJ042833m374358

66.9584

-38.2379

241.1095

-43.7987

117

21

0.56

0.17

1.62

0.16

0°20.1'

1FGL J0428.6-3756

bzb

PKS 0426-380

BM_PKS0537m441

84.4989

-44.5846

250.6323

-31.3151

56

26

1.09

0.34

2.22

0.26

0°31.7'

1FGL J0538.8-4404

bzb

PKS 0537-441

BM_4C21_35

186.2734

21.3873

255.2487

81.6960

53

21

0.77

0.23

2.31

0.26

0° 4.4'

1FGL J1224.7+2121

bzq

4C +21.35

3C_454.3

343.1571

16.3882

85.9437

-37.8063

557

148

6.95

0.78

2.43

0.10

0°24.2'

1FGL J2253.9+1608

BZQ

3C 454.3

Galactic Sources

RA(J2000)

DEC(J2000)

L

B

TS

Npred

Flux¤

Flux err¤

index

index err

Delta

1FGL

Type

Associations

ASPJ023300p614500

39.5210

62.0275

135.0877

1.6993

34

41

1.13

0.34

2.48

0.24

0°51.0'

1FGL J0240.5+6113

HXB

LS I+61 303

Crab_Pulsar

83.4417

21.7950

184.6486

-6.0516

163

70

2.17

0.39

2.07

0.12

0°16.9'

1FGL J0534.5+2200

PSR/PWN

Crab

Geminga

98.2263

18.0285

194.7953

4.1729

552

146

4.34

0.48

1.97

0.08

0°21.0'

1FGL J0633.9+1746

PSR

Geminga

Vela_Pulsar

128.5286

-44.9898

263.2727

-2.8498

1000

297

11.19

0.88

1.98

0.05

0°17.2'

1FGL J0835.3-4510

PSR/PWN

Vela

ASPJ140636m610614

214.1524

-61.1360

313.0283

0.0550

44

82

2.82

0.64

2.50

0.19

0°18.6'
0°32.5'
0°49.1'

1FGL J1418.7-6057
1FGL J1420.1-6048
1FGL J1410.3-6128c

PSR
PSR
spp

LAT PSR J1418-6058
PSR J1420-6048

ASPJ170900m444500

257.1561

-44.2675

343.1580

-2.4000

153

98

2.18

0.41

2.03

0.11

0°17.5'

1FGL J1709.7-4429

PSR

PSR J1709-4429

ASPJ183525p591857

278.4485

59.1978

88.5622

25.2591

136

37

0.84

0.19

1.93

0.15

0°23.1'

1FGL J1836.2+5925

PSR

LAT PSR J1836+5925

ASPJ202214p402203

306.4496

40.7190

78.9176

1.5767

70

83

3.46

0.77

2.42

0.17

0°51.4'

1FGL J2021.5+4026

PSR

LAT PSR J2021+4044

UFOs or ID not found

RA(J2000)

DEC(J2000)

L

B

TS

Npred

Flux¤

Flux err¤

index

index err

Delta

1FGL

Type

Associations

ASPJ175843m241914

270.5089

-23.5442

6.5131

-0.4375

24

66

1.80

0.55

2.38

0.21

0°13.8'
0°34.2'

1FGL J1801.3-2322c
1FGL J1800.5-2359c

spp


 

ASPJ185827p040413

283.8501*

3.8750*

36.8321*

0.8860*

13

44

2.12

0.83

2.87

0.33

0°38.8'

1FGL J1857.9+0352c

 

 

Six hours run (n. 02573)

Extragalactic Sources

RA(J2000)

DEC(J2000)

L

B

TS

Npred

Flux¤

Flux err¤

index

index err

Delta

1FGL

Type

Associations

BM_PKS0537m441

85.3755

-44.8364

251.0341

-30.7381

30

11

1.85

0.80

2.68

0.51

0°53.4'

1FGL J0538.8-4404

bzb

PKS 0537-441

3C_454.3

343.2307

16.5254

86.1146

-37.7317

89

28

5.59

1.48

2.51

0.25

0°27.2'

1FGL J2253.9+1608

BZQ

3C 454.3

Galactic Sources

RA(J2000)

DEC(J2000)

L

B

TS

Npred

Flux¤

Flux err¤

index

index err

Delta

1FGL

Type

Associations

ASPJ053028p211725

83.5160

21.5979

184.8531

-6.0990

21

14

1.97

0.81

2.00

0.27

0°25.8'

1FGL J0534.5+2200

PSR/PWN

Crab

Geminga

98.1463

17.5499

195.1870

3.8862

119

32

4.12

0.96

1.85

0.15

0°23.0'

1FGL J0633.9+1746

PSR

Geminga

Vela_Pulsar

128.4169

-44.9544

263.1971

-2.8922

259

78

14.07

2.20

2.12

0.12

0°22.2'

1FGL J0835.3-4510

PSR/PWN

Vela

ASPJ141410m621049

214.6788

-61.5249

313.1398

-0.3951

27

26

5.09

1.66

2.33

0.26

0°33.8'
0°44.4'
0°50.3'
0°59.7'

1FGL J1418.7-6057
1FGL J1420.1-6048
1FGL J1413.4-6205
1FGL J1410.3-6128c

PSR
PSR
PSR
spp

LAT PSR J1418-6058
PSR J1420-6048
LAT PSR J1413-6205

ASPJ170700m431500

256.5653*

-43.8834*

343.2106*

-1.8298*

4

12

1.77

1.21

2.53

0.51

0°51.8'

1FGL J1709.7-4429

PSR

PSR J1709-4429

ASPJ202138p413136

305.9572

40.8322

78.7954

1.9467

22

21

6.09

2.31

2.63

0.34

0°35.0'
0°43.3'

1FGL J2021.5+4026
1FGL J2020.0+4049

PSR
spp

LAT PSR J2021+4044

UFOs or ID not found

RA(J2000)

DEC(J2000)

L

B

TS

Npred

Flux¤

Flux err¤

index

index err

Delta

1FGL

Type

Associations

ASPJ160207m525005

239.6966

-53.5014

328.6452

-0.2537

1

4

0.55

0.81

2.04

0.76

0°39.7'
0°44.9'

1FGL J1554.8-5312c
1FGL J1554.0-5345c

 

 
 

ASPJ175843m241914

270.3621

-23.6701

6.3371

-0.3828

9

20

2.17

1.03

2.31

0.31

0°17.3'
0°23.4'

1FGL J1801.3-2322c
1FGL J1800.5-2359c

spp


 

Six hours run (n. 02574)

Extragalactic Sources

RA(J2000)

DEC(J2000)

L

B

TS

Npred

Flux¤

Flux err¤

index

index err

Delta

1FGL

Type

Associations

3C_454.3

343.5881

15.8999

86.0352

-38.4425

97

25

7.69

2.08

2.37

0.24

0°15.9'

1FGL J2253.9+1608

BZQ

3C 454.3

Galactic Sources

RA(J2000)

DEC(J2000)

L

B

TS

Npred

Flux¤

Flux err¤

index

index err

Delta

1FGL

Type

A
ssociations

Crab_Pulsar

83.3713

21.4310

184.9223

-6.3021

27

11

1.78

0.82

2.10

0.33

0°37.9'

1FGL J0534.5+2200

PSR/PWN

Crab

Geminga

98.2185

17.9295

194.8801

4.1211

142

32

4.42

1.03

1.86

0.15

0°17.5'

1FGL J0633.9+1746

PSR

Geminga

Vela_Pulsar

128.3848

-45.5357

263.6518

-3.2559

182

48

8.76

1.67

1.92

0.13

0°28.8'

1FGL J0835.3-4510

PSR/PWN

Vela

ASPJ170900m444500

257.2966*

-44.4151*

343.0988*

-2.5684*

23

18

2.55

1.19

2.03

0.29

0° 7.0'

1FGL J1709.7-4429

PSR

PSR 
J1709-4429

Six hours run (n. 02575)

Extragalactic Sources

RA(J2000)

DEC(J2000)

L

B

TS

Npred

Flux¤

Flux err¤

index

index err

Delta

1FGL

Type

Associations

ASPJ225344p172649

343.5292

15.9203

85.9896

-38.3940

185

48

7.73

1.48

2.30

0.16

0°13.9'

1FGL J2253.9+1608

BZQ

3C 454.3

Galactic Sources

RA(J2000)

DEC(J2000)

L

B

TS

Npred

Flux¤

Flux err¤

index

index err

Delta

1FGL

Type

Associations

ASPJ053216p230319

83.5522

21.9081

184.6079

-5.9044

32

15

1.95

0.77

2.02

0.27

0° 7.8'

1FGL J0534.5+2200

PSR/PWN

Crab

Geminga

98.8094

18.1708

194.9216

4.7311

90

27

3.79

0.97

2.12

0.20

0°30.7'

1FGL J0633.9+1746

PSR

Geminga

Vela_Pulsar

128.7164

-45.0504

263.4007

-2.7794

342

99

11.76

1.57

1.95

0.09

0° 9.1'

1FGL J0835.3-4510

PSR/PWN

Vela

ASPJ170900m444500

257.1238*

-44.6383*

342.8459*

-2.6025*

30

29

2.28

0.80

2.29

0.26

0°15.9'

1FGL J1709.7-4429

PSR

PSR J1709-4429

ASPJ202214p402203

306.4649

40.5895

78.8187

1.4923

23

26

3.78

1.48

2.35

0.30

0°50.2'

1FGL J2021.5+4026

PSR

LAT PSR J2021+4044

UFOs or ID not found

RA(J2000)

DEC(J2000)

L

B

TS

Npred

Flux¤

Flux err¤

index

index err

Delta

1FGL

Type

Associations

ASPJ174500m291500

266.4013

-30.3150

358.8218

-0.7159

17

36

3.22

1.19

2.45

0.30

0°30.0'
0°51.3'

1FGL J1747.2-2958
1FGL J1744.0-2931c

PSR

PSR J1747-2958
 

ASPJ223043p584459

337.1041*

59.1324*

105.4829*

1.1944*

17

11

0.97

0.50

1.98

0.30

-

??

 

 

Six hours run (n. 02576)

Extragalactic Sources

RA(J2000)

DEC(J2000)

L

B

TS

Npred

Flux¤

Flux err¤

index

index err

Delta

1FGL

Type

Associations

BM_4C21_35

186.0330

20.9657

256.1614

81.2382

28

8

0.82

0.37

2.01

0.33

0°25.6'

1FGL J1224.7+2121

bzq

4C +21.35

3C_454.3

343.2408

15.9452

85.7140

-38.2186

94

27

8.21

2.20

2.84

0.29

0°19.1'

1FGL J2253.9+1608

BZQ

3C 454.3

Galactic Sources

RA(J2000)

DEC(J2000)

L

B

TS

Npred

Flux¤

Flux err¤

index

index err

Delta

1FGL

Type

Associations

Crab_Pulsar

83.4070

21.8542

184.5810

-6.0471

37

14

2.47

1.01

2.05

0.27

0°15.8'

1FGL J0534.5+2200

PSR/PWN

Crab

Geminga

98.9844

17.7102

195.4092

4.6702

72

23

4.79

1.35

2.14

0.22

0°29.3'

1FGL J0633.9+1746

PSR

Geminga

Vela_Pulsar

129.1460

-44.9519

263.5041

-2.4773

60

16

9.16

3.16

1.90

0.22

0°18.8'

1FGL J0835.3-4510

PSR/PWN

Vela

ASPJ170900m444500

257.1310

-43.8422

343.4888

-2.1317

32

20

2.76

1.03

2.04

0.24

0°40.7'

1FGL J1709.7-4429

PSR

PSR J1709-4429

ASPJ183323p602605

279.1112

59.6693

89.1458

25.0210

32

12

1.07

0.41

2.14

0.32

0°14.7'

1FGL J1836.2+5925

PSR

LAT PSR J1836+5925

UFOs or ID not found

RA(J2000)

DEC(J2000)

L

B

TS

Npred

Flux¤

Flux err¤

index

index err

Delta

1FGL

Type

Associations

ASPJ103300m581500

159.6614*

-58.4111*

286.2648*

0.0965*

2

3

1.39

1.32

2.34

0.86

-

??

 

 

ASPJ184820m01m2551

282.6021*

-1.0383*

31.8905*

-0.2444*

15

8

1.32

0.92

1.73

0.33

0°21.0'
0°22.0'
0°42.7'
0°54.6'

1FGL J1849.0-0055c
1FGL J1849.7-0121c
1FGL J1850.2-0019c
1FGL J1848.1-0145c

 
 
 

 
 
 
 

ASPJ202958p395143

306.1056

39.5971

77.8492

1.1444

15

21

5.77

2.31

3.65

0.70

-

??

 

 

¤ F(E>100MeV) × 10^?6^ ph cm^?2^ s^?1^
* Position is based on PGW-output only: handle with care.