GLAST LAT pulsar research is significantly enhanced if accurate rotation ephemerides for known neutrons stars are available. This is described in "Pulsar Timing for the GLAST Large Area Telescope", D.A. Smith, L. Guillemot, et al, accepted to Astron. Astrophysics, http://lanl.arxiv.org/abs/0810.1637 . Here is Table 1 in LaTeX format.(ascii with &'s separating the columns, basically).
Sustained pulsar monitoring for GLAST is provided by a consortium of radio and X-ray astronomers. A memorandum of understanding describing the consortium's agreement with the LAT collaboration is LAT-MD-09047-01. A memorandum of understanding describing an agreement between the Urumqi radio observatory (Nanshan, China) and the LAT collaboration is LAT-MD-9064-01.
The pulsars being monitored are in the table, below, which was copied from http://www.atnf.csiro.au/people/joh414/glast/ on 23 May, 2008.
List of 224 pulsars with log(Edot) > 34.0
JNAME |
BNAME |
NOTE |
PERIOD |
DM |
AGE |
EDOT |
DIST |
TELESCOPE |
PI |
---|---|---|---|---|---|---|---|---|---|
|
|
|
sec |
|
log |
log |
kpc |
|
|
J0034-0534 |
MSP |
0.002 |
13.76 |
9.78 |
34.48 |
0.5 |
LOVELL |
Kramer |
|
J0034-0534 |
MSP |
0.002 |
13.76 |
9.78 |
34.48 |
0.5 |
NANCAY |
Cognard |
|
J0117+5914 |
B0114+58 |
0.101 |
49.42 |
5.44 |
35.34 |
2.2 |
LOVELL |
Kramer |
|
J0117+5914 |
B0114+58 |
0.101 |
49.42 |
5.44 |
35.34 |
2.2 |
NANCAY |
Cognard |
|
J0139+5814 |
B0136+57 |
0.272 |
73.78 |
5.61 |
34.32 |
2.9 |
LOVELL |
Kramer |
|
J0139+5814 |
B0136+57 |
0.272 |
73.78 |
5.61 |
34.32 |
2.9 |
NANCAY |
Cognard |
|
J0205+6449 |
0.066 |
140.70 |
3.73 |
37.43 |
3.2 |
LOVELL |
Kramer |
||
J0205+6449 |
0.066 |
140.70 |
3.73 |
37.43 |
3.2 |
NANCAY |
Cognard |
||
J0205+6449 |
0.066 |
140.70 |
3.73 |
37.43 |
3.2 |
GBT |
Camilo |
||
J0218+4232 |
MSP |
0.002 |
61.25 |
8.68 |
35.38 |
2.7 |
LOVELL |
Kramer |
|
J0218+4232 |
MSP |
0.002 |
61.25 |
8.68 |
35.38 |
2.7 |
NANCAY |
Cognard |
|
J0358+5413 |
B0355+54 |
0.156 |
57.14 |
5.75 |
34.65 |
1.1 |
LOVELL |
Kramer |
|
J0358+5413 |
B0355+54 |
0.156 |
57.14 |
5.75 |
34.65 |
1.1 |
NANCAY |
Cognard |
|
J0437-4715 |
MSP |
0.006 |
2.64 |
9.20 |
34.08 |
0.1 |
PARKES |
Manchester |
|
J0455-6951 |
B0456-69 |
LMC |
0.320 |
94.89 |
5.70 |
34.08 |
49.4 |
none |
none |
J0534+2200 |
B0531+21 |
Crab |
0.033 |
56.79 |
3.09 |
38.66 |
2.0 |
LOVELL |
Kramer |
J0534+2200 |
B0531+21 |
Crab |
0.033 |
56.79 |
3.09 |
38.66 |
2.0 |
NANCAY |
Cognard |
J0535-6935 |
LMC |
0.201 |
93.70 |
5.44 |
34.75 |
49.4 |
none |
none |
|
J0537-6910 |
X-ray |
0.016 |
3.69 |
38.69 |
49.4 |
RXTE |
Marshall |
||
J0538+2817 |
0.143 |
39.57 |
5.79 |
34.69 |
1.5 |
LOVELL |
Kramer |
||
J0538+2817 |
0.143 |
39.57 |
5.79 |
34.69 |
1.5 |
NANCAY |
Cognard |
||
J0540-6919 |
B0540-69 |
LMC |
0.051 |
146.50 |
3.22 |
38.18 |
49.4 |
RXTE |
Marshall |
J0543+2329 |
B0540+23 |
0.246 |
77.71 |
5.40 |
34.61 |
2.1 |
PARKES |
Weltevrede |
|
J0543+2329 |
B0540+23 |
0.246 |
77.71 |
5.40 |
34.61 |
2.1 |
LOVELL |
Kramer |
|
J0543+2329 |
B0540+23 |
0.246 |
77.71 |
5.40 |
34.61 |
2.1 |
NANCAY |
Cognard |
|
J0613-0200 |
MSP |
0.003 |
38.78 |
9.70 |
34.11 |
1.7 |
PARKES |
Manchester |
|
J0613-0200 |
MSP |
0.003 |
38.78 |
9.70 |
34.11 |
1.7 |
LOVELL |
Kramer |
|
J0613-0200 |
MSP |
0.003 |
38.78 |
9.70 |
34.11 |
1.7 |
NANCAY |
Cognard |
|
J0614+2229 |
B0611+22 |
0.335 |
96.91 |
4.95 |
34.79 |
2.1 |
LOVELL |
Kramer |
|
J0614+2229 |
B0611+22 |
0.335 |
96.91 |
4.95 |
34.79 |
2.1 |
NANCAY |
Cognard |
|
J0627+0705 |
0.476 |
138.20 |
5.40 |
34.04 |
PARKES |
Weltevrede |
|||
J0627+0705 |
0.476 |
138.20 |
5.40 |
34.04 |
LOVELL |
Kramer |
|||
J0631+1036 |
0.288 |
125.40 |
4.64 |
35.23 |
3.7 |
LOVELL |
Kramer |
||
J0631+1036 |
0.288 |
125.40 |
4.64 |
35.23 |
3.7 |
NANCAY |
Cognard |
||
J0633+1746 |
Geminga |
0.237 |
5.53 |
34.51 |
0.2 |
none |
none |
||
J0659+1414 |
B0656+14 |
0.385 |
13.98 |
5.05 |
34.58 |
0.3 |
PARKES |
Weltevrede |
|
J0659+1414 |
B0656+14 |
0.385 |
13.98 |
5.05 |
34.58 |
0.3 |
LOVELL |
Kramer |
|
J0659+1414 |
B0656+14 |
0.385 |
13.98 |
5.05 |
34.58 |
0.3 |
NANCAY |
Cognard |
|
J0729-1448 |
0.252 |
92.30 |
4.55 |
35.45 |
3.5 |
PARKES |
Weltevrede |
||
J0729-1448 |
0.252 |
92.30 |
4.55 |
35.45 |
3.5 |
LOVELL |
Kramer |
||
J0729-1448 |
0.252 |
92.30 |
4.55 |
35.45 |
3.5 |
NANCAY |
Cognard |
||
J0742-2822 |
B0740-28 |
0.167 |
73.78 |
5.20 |
35.15 |
2.1 |
PARKES |
Weltevrede |
|
J0742-2822 |
B0740-28 |
0.167 |
73.78 |
5.20 |
35.15 |
2.1 |
LOVELL |
Kramer |
|
J0745-5353 |
B0743-53 |
0.215 |
122.30 |
6.10 |
34.04 |
0.2 |
PARKES |
Weltevrede |
|
J0821-3824 |
0.125 |
195.60 |
5.91 |
34.70 |
PARKES |
Weltevrede |
|||
J0834-4159 |
0.121 |
240.50 |
5.64 |
35.00 |
1.7 |
PARKES |
Weltevrede |
||
J0835-4510 |
B0833-45 |
Vela |
0.089 |
67.99 |
4.05 |
36.84 |
0.3 |
PARKES |
Weltevrede |
J0855-4644 |
0.065 |
238.20 |
5.15 |
36.04 |
3.9 |
PARKES |
Weltevrede |
||
J0857-4424 |
0.327 |
184.43 |
5.35 |
34.41 |
1.9 |
PARKES |
Weltevrede |
||
J0901-4624 |
0.442 |
198.80 |
4.90 |
34.60 |
2.8 |
PARKES |
Weltevrede |
||
J0905-5127 |
0.346 |
196.43 |
5.34 |
34.38 |
3.3 |
PARKES |
Weltevrede |
||
J0908-4913 |
B0906-49 |
0.107 |
180.37 |
5.05 |
35.69 |
2.5 |
PARKES |
Weltevrede |
|
J0940-5428 |
0.088 |
134.50 |
4.63 |
36.28 |
3.0 |
PARKES |
Weltevrede |
||
J0954-5430 |
0.473 |
200.30 |
5.23 |
34.20 |
3.9 |
PARKES |
Weltevrede |
||
J1003-4747 |
B1001-47 |
0.307 |
98.10 |
5.34 |
34.48 |
2.9 |
PARKES |
Weltevrede |
|
J1015-5719 |
0.140 |
278.70 |
4.59 |
35.92 |
5.1 |
PARKES |
Weltevrede |
||
J1016-5819 |
0.088 |
252.10 |
6.30 |
34.61 |
4.7 |
PARKES |
Weltevrede |
||
J1016-5857 |
0.107 |
394.20 |
4.32 |
36.41 |
8.0 |
PARKES |
Weltevrede |
||
J1019-5749 |
0.162 |
1039.4 |
5.11 |
35.26 |
6.9 |
PARKES |
Weltevrede |
||
J1020-6026 |
0.140 |
445.00 |
5.52 |
34.98 |
12.3 |
PARKES |
Weltevrede |
||
J1043-6116 |
0.289 |
449.20 |
5.64 |
34.23 |
9.5 |
PARKES |
Weltevrede |
||
J1048-5832 |
B1046-58 |
0.124 |
129.10 |
4.31 |
36.30 |
2.7 |
PARKES |
Weltevrede |
|
J1052-5954 |
0.181 |
491.00 |
5.16 |
35.11 |
8.5 |
PARKES |
Weltevrede |
||
J1055-6032 |
0.100 |
633.00 |
4.75 |
36.04 |
PARKES |
Weltevrede |
|||
J1057-5226 |
B1055-52 |
0.197 |
30.10 |
5.73 |
34.48 |
0.7 |
PARKES |
Weltevrede |
|
J1105-6107 |
0.063 |
271.01 |
4.80 |
36.40 |
5.0 |
PARKES |
Weltevrede |
||
J1112-6103 |
0.065 |
599.10 |
4.51 |
36.65 |
12.2 |
PARKES |
Weltevrede |
||
J1115-6052 |
0.260 |
228.20 |
5.76 |
34.20 |
4.1 |
PARKES |
Weltevrede |
||
J1119-6127 |
0.408 |
707.40 |
3.21 |
36.36 |
8.4 |
PARKES |
Weltevrede |
||
J1123-6259 |
0.271 |
223.26 |
5.91 |
34.00 |
4.3 |
PARKES |
Weltevrede |
||
J1124-5916 |
0.135 |
330.00 |
3.46 |
37.08 |
6.5 |
none |
none |
||
J1138-6207 |
0.118 |
519.80 |
5.17 |
35.48 |
9.7 |
PARKES |
Weltevrede |
||
J1156-5707 |
0.288 |
243.50 |
5.24 |
34.64 |
6.0 |
PARKES |
Weltevrede |
||
J1216-6223 |
0.374 |
786.60 |
5.55 |
34.11 |
16.6 |
PARKES |
Weltevrede |
||
J1224-6407 |
B1221-63 |
0.216 |
97.47 |
5.84 |
34.28 |
3.1 |
PARKES |
Weltevrede |
|
J1248-6344 |
0.198 |
433.30 |
5.27 |
34.93 |
8.3 |
PARKES |
Weltevrede |
||
J1300+1240 |
B1257+12 |
MSP |
0.006 |
10.17 |
8.94 |
34.28 |
0.8 |
LOVELL |
Kramer |
J1300+1240 |
B1257+12 |
MSP |
0.006 |
10.17 |
8.94 |
34.28 |
0.8 |
NANCAY |
Cognard |
J1301-6305 |
0.185 |
374.00 |
4.04 |
36.23 |
6.7 |
PARKES |
Weltevrede |
||
J1302-6350 |
B1259-63 |
0.048 |
146.72 |
5.52 |
35.91 |
2.8 |
PARKES |
Weltevrede |
|
J1305-6203 |
0.428 |
470.00 |
5.32 |
34.20 |
8.5 |
PARKES |
Weltevrede |
||
J1320-5359 |
B1317-53 |
0.280 |
97.60 |
5.68 |
34.23 |
2.3 |
PARKES |
Weltevrede |
|
J1327-6400 |
0.281 |
680.90 |
5.16 |
34.75 |
15.5 |
PARKES |
Weltevrede |
||
J1341-6220 |
B1338-62 |
0.193 |
717.30 |
4.08 |
36.15 |
11.1 |
PARKES |
Weltevrede |
|
J1349-6130 |
0.259 |
284.60 |
5.90 |
34.08 |
5.0 |
PARKES |
Weltevrede |
||
J1357-6429 |
0.166 |
128.50 |
3.86 |
36.49 |
2.5 |
PARKES |
Weltevrede |
||
J1359-6038 |
B1356-60 |
0.128 |
293.71 |
5.50 |
35.08 |
5.2 |
PARKES |
Weltevrede |
|
J1406-6121 |
0.213 |
542.30 |
4.79 |
35.34 |
8.2 |
PARKES |
Weltevrede |
||
J1410-6132 |
0.050 |
960.00 |
4.40 |
37.00 |
PARKES |
Weltevrede |
|||
J1412-6145 |
0.315 |
514.70 |
4.70 |
35.08 |
7.8 |
PARKES |
Weltevrede |
||
J1413-6141 |
0.286 |
677.00 |
4.13 |
35.75 |
10.1 |
PARKES |
Weltevrede |
||
J1420-6048 |
0.068 |
360.00 |
4.11 |
37.00 |
5.6 |
PARKES |
Weltevrede |
||
J1452-5851 |
0.387 |
262.40 |
5.08 |
34.54 |
4.3 |
PARKES |
Weltevrede |
||
J1452-6036 |
0.155 |
349.70 |
6.23 |
34.18 |
5.8 |
PARKES |
Weltevrede |
||
J1453-6413 |
B1449-64 |
0.179 |
71.07 |
6.02 |
34.28 |
2.1 |
PARKES |
Weltevrede |
|
J1509-5850 |
0.089 |
137.70 |
5.19 |
35.71 |
2.6 |
PARKES |
Weltevrede |
||
J1512-5759 |
B1508-57 |
0.129 |
628.70 |
5.47 |
35.11 |
7.3 |
PARKES |
Weltevrede |
|
J1513-5908 |
B1509-58 |
0.151 |
252.50 |
3.19 |
37.26 |
4.2 |
PARKES |
Weltevrede |
|
J1514-5925 |
0.149 |
194.10 |
5.91 |
34.54 |
3.5 |
PARKES |
Weltevrede |
||
J1515-5720 |
0.287 |
482.00 |
5.87 |
34.00 |
6.6 |
PARKES |
Weltevrede |
||
J1524-5625 |
0.078 |
152.70 |
4.50 |
36.51 |
2.8 |
PARKES |
Weltevrede |
||
J1524-5706 |
1.116 |
833.00 |
4.70 |
34.00 |
11.4 |
PARKES |
Weltevrede |
||
J1531-5610 |
0.084 |
110.90 |
4.99 |
35.96 |
2.1 |
PARKES |
Weltevrede |
||
J1538-5551 |
0.105 |
603.00 |
5.71 |
35.04 |
7.5 |
PARKES |
Weltevrede |
||
J1539-5626 |
B1535-56 |
0.243 |
175.88 |
5.90 |
34.11 |
3.1 |
PARKES |
Weltevrede |
|
J1541-5535 |
0.296 |
428.00 |
4.80 |
35.04 |
5.7 |
PARKES |
Weltevrede |
||
J1543-5459 |
0.377 |
345.70 |
5.06 |
34.58 |
4.8 |
PARKES |
Weltevrede |
||
J1548-5607 |
0.171 |
315.50 |
5.40 |
34.93 |
4.9 |
PARKES |
Weltevrede |
||
J1549-4848 |
0.288 |
55.98 |
5.51 |
34.36 |
2.7 |
PARKES |
Weltevrede |
||
J1550-5418 |
Magnetar |
2.070 |
830.00 |
3.15 |
35.00 |
9.6 |
none |
none |
|
J1551-5310 |
0.453 |
493.00 |
4.57 |
34.92 |
7.8 |
PARKES |
Weltevrede |
||
J1600-5044 |
B1557-50 |
0.193 |
260.56 |
5.78 |
34.45 |
6.7 |
PARKES |
Weltevrede |
|
J1600-5751 |
B1556-57 |
0.194 |
176.55 |
6.16 |
34.04 |
3.5 |
PARKES |
Weltevrede |
|
J1601-5335 |
0.288 |
194.60 |
4.87 |
35.00 |
4.5 |
PARKES |
Weltevrede |
||
J1611-5209 |
B1607-52 |
0.182 |
127.57 |
5.75 |
34.53 |
4.3 |
PARKES |
Weltevrede |
|
J1614-5048 |
B1610-50 |
0.232 |
582.80 |
3.87 |
36.20 |
7.9 |
PARKES |
Weltevrede |
|
J1617-5055 |
0.069 |
467.00 |
3.90 |
37.20 |
6.8 |
PARKES |
Weltevrede |
||
J1623-2631 |
B1620-26 |
MSP |
0.011 |
62.86 |
8.42 |
34.28 |
2.2 |
LOVELL |
Kramer |
J1623-2631 |
B1620-26 |
MSP |
0.011 |
62.86 |
8.42 |
34.28 |
2.2 |
NANCAY |
Cognard |
J1626-4807 |
0.294 |
817.00 |
5.42 |
34.43 |
8.9 |
PARKES |
Weltevrede |
||
J1627-4706 |
0.141 |
456.10 |
6.11 |
34.40 |
6.1 |
PARKES |
Weltevrede |
||
J1632-4757 |
0.229 |
578.00 |
5.38 |
34.70 |
6.4 |
PARKES |
Weltevrede |
||
J1632-4818 |
0.813 |
758.00 |
4.30 |
34.68 |
7.8 |
PARKES |
Weltevrede |
||
J1637-4553 |
B1634-45 |
0.119 |
193.23 |
5.77 |
34.88 |
3.2 |
PARKES |
Weltevrede |
|
J1637-4642 |
0.154 |
417.00 |
4.61 |
35.81 |
5.1 |
PARKES |
Weltevrede |
||
J1638-4417 |
0.118 |
436.00 |
6.06 |
34.59 |
6.2 |
PARKES |
Weltevrede |
||
J1638-4608 |
0.278 |
424.30 |
4.93 |
34.97 |
5.2 |
PARKES |
Weltevrede |
||
J1640-4715 |
B1636-47 |
0.517 |
591.70 |
5.29 |
34.08 |
6.5 |
PARKES |
Weltevrede |
|
J1643-4505 |
0.237 |
484.00 |
5.07 |
34.97 |
5.6 |
PARKES |
Weltevrede |
||
J1646-4346 |
B1643-43 |
0.232 |
490.40 |
4.51 |
35.56 |
5.8 |
PARKES |
Weltevrede |
|
J1648-4611 |
0.165 |
392.90 |
5.04 |
35.32 |
5.0 |
PARKES |
Weltevrede |
||
J1649-4653 |
0.557 |
332.00 |
5.25 |
34.04 |
4.7 |
PARKES |
Weltevrede |
||
J1650-4502 |
0.381 |
319.70 |
5.58 |
34.04 |
4.4 |
PARKES |
Weltevrede |
||
J1650-4921 |
0.156 |
229.90 |
6.13 |
34.28 |
4.1 |
PARKES |
Weltevrede |
||
J1702-4128 |
0.182 |
367.10 |
4.74 |
35.53 |
4.8 |
PARKES |
Weltevrede |
||
J1702-4305 |
0.216 |
537.90 |
5.54 |
34.59 |
PARKES |
Weltevrede |
|||
J1702-4310 |
0.241 |
377.00 |
4.23 |
35.80 |
5.1 |
PARKES |
Weltevrede |
||
J1705-3950 |
0.319 |
207.10 |
4.92 |
34.87 |
3.3 |
PARKES |
Weltevrede |
||
J1709-4429 |
B1706-44 |
0.102 |
75.69 |
4.24 |
36.53 |
2.3 |
PARKES |
Weltevrede |
|
J1715-3903 |
0.278 |
313.10 |
5.07 |
34.84 |
4.1 |
PARKES |
Weltevrede |
||
J1718-3825 |
0.075 |
247.40 |
4.95 |
36.11 |
3.6 |
PARKES |
Weltevrede |
||
J1718-3825 |
0.075 |
247.40 |
4.95 |
36.11 |
3.6 |
NANCAY |
Cognard |
||
J1721-3532 |
B1718-35 |
0.280 |
496.00 |
5.25 |
34.65 |
5.6 |
PARKES |
Weltevrede |
|
J1721-3532 |
B1718-35 |
0.280 |
496.00 |
5.25 |
34.65 |
5.6 |
LOVELL |
Kramer |
|
J1721-3532 |
B1718-35 |
0.280 |
496.00 |
5.25 |
34.65 |
5.6 |
NANCAY |
Cognard |
|
J1722-3712 |
B1719-37 |
0.236 |
99.50 |
5.54 |
34.52 |
1.9 |
PARKES |
Weltevrede |
|
J1722-3712 |
B1719-37 |
0.236 |
99.50 |
5.54 |
34.52 |
1.9 |
NANCAY |
Cognard |
|
J1723-3659 |
0.203 |
254.20 |
5.60 |
34.58 |
3.5 |
PARKES |
Weltevrede |
||
J1723-3659 |
0.203 |
254.20 |
5.60 |
34.58 |
3.5 |
NANCAY |
Cognard |
||
J1726-3530 |
1.110 |
727.00 |
4.16 |
34.54 |
8.4 |
PARKES |
Weltevrede |
||
J1726-3530 |
1.110 |
727.00 |
4.16 |
34.54 |
8.4 |
NANCAY |
Cognard |
||
J1730-3350 |
B1727-33 |
0.139 |
259.00 |
4.41 |
36.08 |
3.5 |
PARKES |
Weltevrede |
|
J1730-3350 |
B1727-33 |
0.139 |
259.00 |
4.41 |
36.08 |
3.5 |
LOVELL |
Kramer |
|
J1730-3350 |
B1727-33 |
0.139 |
259.00 |
4.41 |
36.08 |
3.5 |
NANCAY |
Cognard |
|
J1731-4744 |
B1727-47 |
0.830 |
123.33 |
4.91 |
34.04 |
2.8 |
PARKES |
Weltevrede |
|
J1733-3716 |
B1730-37 |
0.338 |
153.50 |
5.55 |
34.18 |
2.8 |
PARKES |
Weltevrede |
|
J1733-3716 |
B1730-37 |
0.338 |
153.50 |
5.55 |
34.18 |
2.8 |
NANCAY |
Cognard |
|
J1734-3333 |
1.169 |
578.00 |
3.91 |
34.75 |
6.5 |
PARKES |
Weltevrede |
||
J1734-3333 |
1.169 |
578.00 |
3.91 |
34.75 |
6.5 |
LOVELL |
Kramer |
||
J1735-3258 |
0.351 |
754.00 |
5.33 |
34.38 |
9.6 |
PARKES |
Weltevrede |
||
J1735-3258 |
0.351 |
754.00 |
5.33 |
34.38 |
9.6 |
LOVELL |
Kramer |
||
J1735-3258 |
0.351 |
754.00 |
5.33 |
34.38 |
9.6 |
NANCAY |
Cognard |
||
J1737-3137 |
0.450 |
488.20 |
4.71 |
34.78 |
5.5 |
PARKES |
Weltevrede |
||
J1737-3137 |
0.450 |
488.20 |
4.71 |
34.78 |
5.5 |
LOVELL |
Kramer |
||
J1737-3137 |
0.450 |
488.20 |
4.71 |
34.78 |
5.5 |
NANCAY |
Cognard |
||
J1738-2955 |
0.443 |
223.40 |
4.93 |
34.57 |
3.5 |
PARKES |
Weltevrede |
||
J1738-2955 |
0.443 |
223.40 |
4.93 |
34.57 |
3.5 |
LOVELL |
Kramer |
||
J1738-2955 |
0.443 |
223.40 |
4.93 |
34.57 |
3.5 |
NANCAY |
Cognard |
||
J1739-3023 |
0.114 |
170.00 |
5.20 |
35.48 |
2.9 |
PARKES |
Weltevrede |
||
J1739-3023 |
0.114 |
170.00 |
5.20 |
35.48 |
2.9 |
LOVELL |
Kramer |
||
J1739-3023 |
0.114 |
170.00 |
5.20 |
35.48 |
2.9 |
NANCAY |
Cognard |
||
J1740+1000 |
0.154 |
23.85 |
5.06 |
35.36 |
1.2 |
LOVELL |
Kramer |
||
J1740+1000 |
0.154 |
23.85 |
5.06 |
35.36 |
1.2 |
NANCAY |
Cognard |
||
J1740-3015 |
B1737-30 |
0.607 |
152.15 |
4.31 |
34.91 |
2.7 |
PARKES |
Weltevrede |
|
J1740-3015 |
B1737-30 |
0.607 |
152.15 |
4.31 |
34.91 |
2.7 |
LOVELL |
Kramer |
|
J1740-3015 |
B1737-30 |
0.607 |
152.15 |
4.31 |
34.91 |
2.7 |
NANCAY |
Cognard |
|
J1741+1351 |
MSP |
0.004 |
24.20 |
9.29 |
34.36 |
0.5 |
none |
none |
|
J1743-3153 |
0.193 |
505.70 |
5.46 |
34.76 |
6.6 |
LOVELL |
Kramer |
||
J1743-3153 |
0.193 |
505.70 |
5.46 |
34.76 |
6.6 |
NANCAY |
Cognard |
||
J1747-2958 |
0.099 |
101.50 |
4.41 |
36.40 |
2.0 |
NANCAY |
Cognard |
||
J1747-2958 |
0.099 |
101.50 |
4.41 |
36.40 |
2.0 |
GBT |
Camilo |
||
J1755-2534 |
0.234 |
590.00 |
5.52 |
34.54 |
7.1 |
LOVELL |
Kramer |
||
J1756-2225 |
0.405 |
326.00 |
5.09 |
34.49 |
5.0 |
PARKES |
Weltevrede |
||
J1756-2225 |
0.405 |
326.00 |
5.09 |
34.49 |
5.0 |
LOVELL |
Kramer |
||
J1757-2421 |
B1754-24 |
0.234 |
179.45 |
5.46 |
34.60 |
4.4 |
PARKES |
Weltevrede |
|
J1757-2421 |
B1754-24 |
0.234 |
179.45 |
5.46 |
34.60 |
4.4 |
LOVELL |
Kramer |
|
J1757-2421 |
B1754-24 |
0.234 |
179.45 |
5.46 |
34.60 |
4.4 |
NANCAY |
Cognard |
|
J1801-2154 |
0.375 |
387.90 |
5.57 |
34.08 |
5.3 |
PARKES |
Weltevrede |
||
J1801-2304 |
B1758-23 |
0.416 |
1073.9 |
4.77 |
34.79 |
12.6 |
PARKES |
Weltevrede |
|
J1801-2304 |
B1758-23 |
0.416 |
1073.9 |
4.77 |
34.79 |
12.6 |
LOVELL |
Kramer |
|
J1801-2304 |
B1758-23 |
0.416 |
1073.9 |
4.77 |
34.79 |
12.6 |
NANCAY |
Cognard |
|
J1801-2451 |
B1757-24 |
0.125 |
289.00 |
4.19 |
36.41 |
5.2 |
PARKES |
Weltevrede |
|
J1801-2451 |
B1757-24 |
0.125 |
289.00 |
4.19 |
36.41 |
5.2 |
LOVELL |
Kramer |
|
J1801-2451 |
B1757-24 |
0.125 |
289.00 |
4.19 |
36.41 |
5.2 |
NANCAY |
Cognard |
|
J1803-2137 |
B1800-21 |
0.134 |
233.99 |
4.20 |
36.34 |
3.9 |
PARKES |
Weltevrede |
|
J1803-2137 |
B1800-21 |
0.134 |
233.99 |
4.20 |
36.34 |
3.9 |
LOVELL |
Kramer |
|
J1803-2137 |
B1800-21 |
0.134 |
233.99 |
4.20 |
36.34 |
3.9 |
NANCAY |
Cognard |
|
J1806-2125 |
0.482 |
750.40 |
4.80 |
34.63 |
9.8 |
PARKES |
Weltevrede |
||
J1806-2125 |
0.482 |
750.40 |
4.80 |
34.63 |
9.8 |
LOVELL |
Kramer |
||
J1808-2024 |
SGR |
7.556 |
2.34 |
34.70 |
13.1 |
none |
none |
||
J1809-1917 |
0.083 |
197.10 |
4.71 |
36.26 |
3.5 |
PARKES |
Weltevrede |
||
J1809-1917 |
0.083 |
197.10 |
4.71 |
36.26 |
3.5 |
LOVELL |
Kramer |
||
J1809-1917 |
0.083 |
197.10 |
4.71 |
36.26 |
3.5 |
NANCAY |
Cognard |
||
J1811-1925 |
X-ray |
0.065 |
4.37 |
36.81 |
RXTE |
Kaspi |
|||
J1812-1910 |
0.431 |
892.00 |
5.26 |
34.28 |
11.2 |
PARKES |
Weltevrede |
||
J1812-1910 |
0.431 |
892.00 |
5.26 |
34.28 |
11.2 |
LOVELL |
Kramer |
||
J1815-1738 |
0.198 |
728.00 |
4.61 |
35.59 |
8.8 |
PARKES |
Weltevrede |
||
J1816-0755 |
0.218 |
116.80 |
5.73 |
34.40 |
2.8 |
LOVELL |
Kramer |
||
J1820-1529 |
0.333 |
772.00 |
5.14 |
34.60 |
8.9 |
PARKES |
Weltevrede |
||
J1820-1529 |
0.333 |
772.00 |
5.14 |
34.60 |
8.9 |
LOVELL |
Kramer |
||
J1824-1945 |
B1821-19 |
0.189 |
224.65 |
5.76 |
34.48 |
4.7 |
PARKES |
Weltevrede |
|
J1824-1945 |
B1821-19 |
0.189 |
224.65 |
5.76 |
34.48 |
4.7 |
LOVELL |
Kramer |
|
J1824-2452 |
B1821-24 |
MSP |
0.003 |
119.80 |
7.48 |
36.34 |
4.9 |
PARKES |
Manchester |
J1824-2452 |
B1821-24 |
MSP |
0.003 |
119.80 |
7.48 |
36.34 |
4.9 |
LOVELL |
Kramer |
J1824-2452 |
B1821-24 |
MSP |
0.003 |
119.80 |
7.48 |
36.34 |
4.9 |
NANCAY |
Cognard |
J1825-1446 |
B1822-14 |
0.279 |
357.00 |
5.29 |
34.61 |
5.1 |
PARKES |
Weltevrede |
|
J1825-1446 |
B1822-14 |
0.279 |
357.00 |
5.29 |
34.61 |
5.1 |
LOVELL |
Kramer |
|
J1826-1334 |
B1823-13 |
0.101 |
231.00 |
4.33 |
36.45 |
3.9 |
PARKES |
Weltevrede |
|
J1826-1334 |
B1823-13 |
0.101 |
231.00 |
4.33 |
36.45 |
3.9 |
LOVELL |
Kramer |
|
J1826-1334 |
B1823-13 |
0.101 |
231.00 |
4.33 |
36.45 |
3.9 |
NANCAY |
Cognard |
|
J1828-1057 |
0.246 |
245.00 |
5.28 |
34.74 |
4.0 |
PARKES |
Weltevrede |
||
J1828-1057 |
0.246 |
245.00 |
5.28 |
34.74 |
4.0 |
LOVELL |
Kramer |
||
J1828-1101 |
0.072 |
607.40 |
4.89 |
36.20 |
6.6 |
PARKES |
Weltevrede |
||
J1828-1101 |
0.072 |
607.40 |
4.89 |
36.20 |
6.6 |
LOVELL |
Kramer |
||
J1828-1101 |
0.072 |
607.40 |
4.89 |
36.20 |
6.6 |
NANCAY |
Cognard |
||
J1830-0131 |
0.153 |
95.70 |
6.06 |
34.36 |
2.6 |
LOVELL |
Kramer |
||
J1830-1059 |
B1828-11 |
0.405 |
161.50 |
5.03 |
34.56 |
3.2 |
PARKES |
Weltevrede |
|
J1830-1059 |
B1828-11 |
0.405 |
161.50 |
5.03 |
34.56 |
3.2 |
LOVELL |
Kramer |
|
J1830-1059 |
B1828-11 |
0.405 |
161.50 |
5.03 |
34.56 |
3.2 |
NANCAY |
Cognard |
|
J1831-0952 |
0.067 |
247.00 |
5.11 |
36.04 |
4.0 |
PARKES |
Weltevrede |
||
J1831-0952 |
0.067 |
247.00 |
5.11 |
36.04 |
4.0 |
LOVELL |
Kramer |
||
J1833-0827 |
B1830-08 |
0.085 |
411.00 |
5.17 |
35.76 |
4.7 |
PARKES |
Weltevrede |
|
J1833-0827 |
B1830-08 |
0.085 |
411.00 |
5.17 |
35.76 |
4.7 |
LOVELL |
Kramer |
|
J1833-0827 |
B1830-08 |
0.085 |
411.00 |
5.17 |
35.76 |
4.7 |
NANCAY |
Cognard |
|
J1833-1034 |
0.062 |
169.50 |
3.69 |
37.53 |
4.3 |
GBT |
Camilo |
||
J1834-0731 |
0.513 |
295.00 |
5.15 |
34.23 |
5.1 |
PARKES |
Weltevrede |
||
J1834-0731 |
0.513 |
295.00 |
5.15 |
34.23 |
5.1 |
LOVELL |
Kramer |
||
J1835-0643 |
B1832-06 |
0.306 |
472.90 |
5.08 |
34.75 |
6.2 |
PARKES |
Weltevrede |
|
J1835-0643 |
B1832-06 |
0.306 |
472.90 |
5.08 |
34.75 |
6.2 |
LOVELL |
Kramer |
|
J1835-0944 |
0.145 |
277.20 |
5.72 |
34.75 |
4.4 |
PARKES |
Weltevrede |
||
J1835-0944 |
0.145 |
277.20 |
5.72 |
34.75 |
4.4 |
LOVELL |
Kramer |
||
J1835-1106 |
0.166 |
132.68 |
5.11 |
35.26 |
2.8 |
PARKES |
Weltevrede |
||
J1835-1106 |
0.166 |
132.68 |
5.11 |
35.26 |
2.8 |
LOVELL |
Kramer |
||
J1837-0559 |
0.201 |
317.80 |
5.98 |
34.20 |
5.4 |
PARKES |
Weltevrede |
||
J1837-0559 |
0.201 |
317.80 |
5.98 |
34.20 |
5.4 |
LOVELL |
Kramer |
||
J1837-0604 |
0.096 |
462.00 |
4.53 |
36.30 |
6.4 |
PARKES |
Weltevrede |
||
J1838-0453 |
0.381 |
621.00 |
4.72 |
34.92 |
8.1 |
PARKES |
Weltevrede |
||
J1838-0453 |
0.381 |
621.00 |
4.72 |
34.92 |
8.1 |
LOVELL |
Kramer |
||
J1838-0453 |
0.381 |
621.00 |
4.72 |
34.92 |
8.1 |
NANCAY |
Cognard |
||
J1838-0549 |
0.235 |
274.00 |
5.05 |
35.00 |
5.1 |
PARKES |
Weltevrede |
||
J1839-0321 |
0.239 |
449.10 |
5.48 |
34.56 |
7.2 |
PARKES |
Weltevrede |
||
J1839-0321 |
0.239 |
449.10 |
5.48 |
34.56 |
7.2 |
LOVELL |
Kramer |
||
J1839-0905 |
0.419 |
348.00 |
5.41 |
34.15 |
5.4 |
PARKES |
Weltevrede |
||
J1841+0130 |
MSP |
0.030 |
125.88 |
7.76 |
34.08 |
3.6 |
LOVELL |
Kramer |
|
J1841-0345 |
0.204 |
194.32 |
4.75 |
35.43 |
4.8 |
LOVELL |
Kramer |
||
J1841-0345 |
0.204 |
194.32 |
4.75 |
35.43 |
4.8 |
NANCAY |
Cognard |
||
J1841-0425 |
B1838-04 |
0.186 |
325.49 |
5.66 |
34.59 |
5.7 |
PARKES |
Weltevrede |
|
J1841-0425 |
B1838-04 |
0.186 |
325.49 |
5.66 |
34.59 |
5.7 |
LOVELL |
Kramer |
|
J1841-0425 |
B1838-04 |
0.186 |
325.49 |
5.66 |
34.59 |
5.7 |
NANCAY |
Cognard |
|
J1841-0524 |
0.446 |
289.00 |
4.48 |
35.00 |
5.3 |
PARKES |
Weltevrede |
||
J1841-0524 |
0.446 |
289.00 |
4.48 |
35.00 |
5.3 |
LOVELL |
Kramer |
||
J1842-0905 |
0.345 |
343.30 |
5.72 |
34.00 |
5.9 |
PARKES |
Weltevrede |
||
J1842-0905 |
0.345 |
343.30 |
5.72 |
34.00 |
5.9 |
LOVELL |
Kramer |
||
J1843-0355 |
0.132 |
797.60 |
6.31 |
34.26 |
8.8 |
PARKES |
Weltevrede |
||
J1843-0355 |
0.132 |
797.60 |
6.31 |
34.26 |
8.8 |
LOVELL |
Kramer |
||
J1843-0702 |
0.192 |
228.10 |
6.15 |
34.08 |
4.8 |
PARKES |
Weltevrede |
||
J1843-1113 |
MSP |
0.002 |
59.96 |
9.48 |
34.78 |
1.7 |
LOVELL |
Kramer |
|
J1843-1113 |
MSP |
0.002 |
59.96 |
9.48 |
34.78 |
1.7 |
NANCAY |
Cognard |
|
J1844-0256 |
0.273 |
820.20 |
5.18 |
34.74 |
9.2 |
PARKES |
Weltevrede |
||
J1844-0538 |
B1841-05 |
0.256 |
412.80 |
5.62 |
34.36 |
6.5 |
PARKES |
Weltevrede |
|
J1844-0538 |
B1841-05 |
0.256 |
412.80 |
5.62 |
34.36 |
6.5 |
LOVELL |
Kramer |
|
J1844-0538 |
B1841-05 |
0.256 |
412.80 |
5.62 |
34.36 |
6.5 |
NANCAY |
Cognard |
|
J1845-0316 |
0.208 |
500.00 |
5.57 |
34.59 |
7.0 |
LOVELL |
Kramer |
||
J1845-0743 |
0.105 |
281.00 |
6.66 |
34.11 |
5.2 |
PARKES |
Weltevrede |
||
J1845-0743 |
0.105 |
281.00 |
6.66 |
34.11 |
5.2 |
LOVELL |
Kramer |
||
J1845-0743 |
0.105 |
281.00 |
6.66 |
34.11 |
5.2 |
NANCAY |
Cognard |
||
J1846-0258 |
X-ray |
0.326 |
2.86 |
36.91 |
RXTE |
Gotthelf |
|||
J1853+0011 |
0.398 |
568.80 |
5.27 |
34.32 |
8.1 |
none |
none |
||
J1853+0056 |
0.276 |
180.90 |
5.31 |
34.60 |
5.1 |
LOVELL |
Kramer |
||
J1853+0545 |
0.126 |
198.70 |
6.52 |
34.08 |
5.3 |
LOVELL |
Kramer |
||
J1853+0545 |
0.126 |
198.70 |
6.52 |
34.08 |
5.3 |
NANCAY |
Cognard |
||
J1853-0004 |
0.101 |
438.20 |
5.46 |
35.32 |
7.2 |
PARKES |
Weltevrede |
||
J1853-0004 |
0.101 |
438.20 |
5.46 |
35.32 |
7.2 |
LOVELL |
Kramer |
||
J1853-0004 |
0.101 |
438.20 |
5.46 |
35.32 |
7.2 |
NANCAY |
Cognard |
||
J1856+0113 |
B1853+01 |
0.267 |
96.74 |
4.31 |
35.63 |
3.3 |
LOVELL |
Kramer |
|
J1857+0143 |
0.140 |
249.00 |
4.85 |
35.65 |
5.8 |
LOVELL |
Kramer |
||
J1857+0212 |
B1855+02 |
0.416 |
506.77 |
5.21 |
34.34 |
8.0 |
LOVELL |
Kramer |
|
J1903+0601 |
0.374 |
388.00 |
5.49 |
34.15 |
7.2 |
LOVELL |
Kramer |
||
J1903+0925 |
0.357 |
162.00 |
5.18 |
34.51 |
4.9 |
none |
none |
||
J1904+0800 |
0.263 |
438.80 |
5.38 |
34.57 |
8.6 |
LOVELL |
Kramer |
||
J1906+0746 |
0.144 |
217.78 |
5.05 |
35.43 |
5.4 |
NANCAY |
Cognard |
||
J1907+0345 |
0.240 |
311.70 |
5.67 |
34.36 |
7.2 |
NANCAY |
Cognard |
||
J1907+0731 |
0.364 |
239.80 |
5.50 |
34.18 |
5.7 |
NANCAY |
Cognard |
||
J1907+0918 |
0.226 |
357.90 |
4.58 |
35.51 |
7.8 |
LOVELL |
Kramer |
||
J1907+0918 |
0.226 |
357.90 |
4.58 |
35.51 |
7.8 |
NANCAY |
Cognard |
||
J1907+0919 |
SGR |
5.169 |
3.02 |
34.34 |
none |
none |
|||
J1908+0839 |
0.185 |
512.10 |
6.09 |
34.18 |
9.3 |
LOVELL |
Kramer |
||
J1908+0909 |
0.337 |
467.50 |
5.18 |
34.56 |
9.0 |
LOVELL |
Kramer |
||
J1909+0912 |
0.223 |
421.50 |
4.99 |
35.11 |
8.2 |
LOVELL |
Kramer |
||
J1909-3744 |
MSP |
0.003 |
10.39 |
9.52 |
34.34 |
1.1 |
PARKES |
Manchester |
|
J1909-3744 |
MSP |
0.003 |
10.39 |
9.52 |
34.34 |
1.1 |
NANCAY |
Cognard |
|
J1911-1114 |
MSP |
0.004 |
30.98 |
9.61 |
34.08 |
1.2 |
LOVELL |
Kramer |
|
J1911-1114 |
MSP |
0.004 |
30.98 |
9.61 |
34.08 |
1.2 |
NANCAY |
Cognard |
|
J1913+0832 |
0.134 |
355.20 |
5.67 |
34.87 |
7.9 |
LOVELL |
Kramer |
||
J1913+0832 |
0.134 |
355.20 |
5.67 |
34.87 |
7.9 |
NANCAY |
Cognard |
||
J1913+0904 |
0.163 |
95.30 |
5.17 |
35.20 |
3.0 |
LOVELL |
Kramer |
||
J1913+1011 |
0.036 |
178.80 |
5.23 |
36.46 |
4.8 |
LOVELL |
Kramer |
||
J1913+1011 |
0.036 |
178.80 |
5.23 |
36.46 |
4.8 |
NANCAY |
Cognard |
||
J1917+1353 |
B1915+13 |
0.195 |
94.54 |
5.63 |
34.59 |
4.0 |
LOVELL |
Kramer |
|
J1917+1353 |
B1915+13 |
0.195 |
94.54 |
5.63 |
34.59 |
4.0 |
NANCAY |
Cognard |
|
J1921+0812 |
0.211 |
84.00 |
5.79 |
34.36 |
3.5 |
LOVELL |
Kramer |
||
J1928+1746 |
0.069 |
176.90 |
4.92 |
36.20 |
5.8 |
LOVELL |
Kramer |
||
J1930+1852 |
0.137 |
308.00 |
3.46 |
37.08 |
5.0 |
GBT |
Camilo |
||
J1932+2220 |
B1930+22 |
0.144 |
219.20 |
4.60 |
35.88 |
9.8 |
LOVELL |
Kramer |
|
J1932+2220 |
B1930+22 |
0.144 |
219.20 |
4.60 |
35.88 |
9.8 |
NANCAY |
Cognard |
|
J1939+2134 |
B1937+21 |
MSP |
0.002 |
71.04 |
8.37 |
36.04 |
8.3 |
PARKES |
Manchester |
J1939+2134 |
B1937+21 |
MSP |
0.002 |
71.04 |
8.37 |
36.04 |
8.3 |
LOVELL |
Kramer |
J1939+2134 |
B1937+21 |
MSP |
0.002 |
71.04 |
8.37 |
36.04 |
8.3 |
NANCAY |
Cognard |
J1946+2611 |
0.435 |
165.00 |
5.50 |
34.04 |
6.1 |
LOVELL |
Kramer |
||
J1946+2611 |
0.435 |
165.00 |
5.50 |
34.04 |
6.1 |
NANCAY |
Cognard |
||
J1952+3252 |
B1951+32 |
0.040 |
45.01 |
5.03 |
36.57 |
2.5 |
LOVELL |
Kramer |
|
J1952+3252 |
B1951+32 |
0.040 |
45.01 |
5.03 |
36.57 |
2.5 |
NANCAY |
Cognard |
|
J1959+2048 |
B1957+20 |
MSP |
0.002 |
29.12 |
9.18 |
35.20 |
2.5 |
NANCAY |
Cognard |
J2002+3217 |
B2000+32 |
0.697 |
142.21 |
5.02 |
34.08 |
5.7 |
LOVELL |
Kramer |
|
J2002+3217 |
B2000+32 |
0.697 |
142.21 |
5.02 |
34.08 |
5.7 |
NANCAY |
Cognard |
|
J2013+3845 |
B2011+38 |
0.230 |
238.22 |
5.61 |
34.46 |
8.4 |
LOVELL |
Kramer |
|
J2013+3845 |
B2011+38 |
0.230 |
238.22 |
5.61 |
34.46 |
8.4 |
NANCAY |
Cognard |
|
J2021+3651 |
0.104 |
371.00 |
4.24 |
36.53 |
12.4 |
LOVELL |
Kramer |
||
J2021+3651 |
0.104 |
371.00 |
4.24 |
36.53 |
12.4 |
NANCAY |
Cognard |
||
J2021+3651 |
0.104 |
371.00 |
4.24 |
36.53 |
12.4 |
GBT |
Camilo |
||
J2043+2740 |
0.096 |
21.00 |
6.08 |
34.75 |
1.8 |
LOVELL |
Kramer |
||
J2129-5721 |
MSP |
0.004 |
31.87 |
9.45 |
34.20 |
1.4 |
PARKES |
Manchester |
|
J2150+5247 |
B2148+52 |
0.332 |
148.93 |
5.72 |
34.04 |
4.6 |
LOVELL |
Kramer |
|
J2150+5247 |
B2148+52 |
0.332 |
148.93 |
5.72 |
34.04 |
4.6 |
NANCAY |
Cognard |
|
J2229+6114 |
0.052 |
200.00 |
4.02 |
37.34 |
7.2 |
LOVELL |
Kramer |
||
J2229+6114 |
0.052 |
200.00 |
4.02 |
37.34 |
7.2 |
NANCAY |
Cognard |
||
J2229+6114 |
0.052 |
200.00 |
4.02 |
37.34 |
7.2 |
GBT |
Camilo |
||
J2337+6151 |
B2334+61 |
0.495 |
58.41 |
4.61 |
34.79 |
3.1 |
LOVELL |
Kramer |
|
J2337+6151 |
B2334+61 |
0.495 |
58.41 |
4.61 |
34.79 |
3.1 |
NANCAY |
Cognard |