H2 Sasha's occupency plots

LEX8 channel


HEX8 channel

Sacha's page

LAC distribution



LAC thresholds distribution for nomSciOps (runs 236096298,236102471,236108455)  
 
 
 LAC thresholds distribution for conSciOps (run 236084237)

 

 
 

Face # 1


LAC distribution and pedestal drift for LEX8 channel obtained with calibGenCal code

Here is the list of the channel with important drift (this is the output of the caliGenCal code)

;twr lyr col face lac errlac pedDrift lacMeV fitstat chi2 mev_slope mev_offset
6 7 4 1 70 0.131019 -21.7037 62124.2 0 475.23 677.445 0
7 6 10 1 65 0.0740706 -16.5728 65511.2 0 866.965 803.102 0
7 7 8 1 58.7911 0.591242 -17.089 40791.9 0 485.018 537.584 0
11 3 1 1 68.3136 0.619018 -21.9891 56844.6 0 403.708 629.489 0
13 4 10 1 60 0.0801621 -18.7812 65397.1 0 422.537 830.111 0
13 5 4 1 75 0.121373 -17.0343 55793.4 0 333.782 606.224 0
14 5 1 1 70 0.0427609 -18.398 50532.3 0 531.081 571.646 0

here is the histogram for T6L7C4F1

Face # 0


LAC distribution and pedestal drift for LEX8 channel obtained with calibGenCal code

FLE, FHE distribution

Face # 1

FLE and FHE distribution obtained with calibGenCal code

Face # 0

FLE and FHE distribution obtained with calibGenCal code

Events distribution : variable CalMaxEne


CalMaxEne>>hflefhe","CalMaxEne>0 && (GemConditionsWord==12 || GemConditionsWord==13 || GemConditionsWord==14 || GemConditionsWord==15)
events with FLE and FHE trigger


CalMaxEne>>hflenofhe","CalMaxEne>0 && (GemConditionsWord==4 || GemConditionsWord==5 || GemConditionsWord==6 || GemConditionsWord==7)
events with FLE and NO FHE trigger


CalMaxEne>>hnoflefhe","CalMaxEne>0 && (GemConditionsWord==8 ||GemConditionsWord==9 || GemConditionsWord==10 || GemConditionsWord==11)
events with NO FLE and FHE trigger


CalMaxEne>>hnoflenofhe","CalMaxEne>0 && (GemConditionsWord==1 || GemConditionsWord==2 || GemConditionsWord==3 )
events with N0 FLE and N0 FHE trigger

FHE and FLE distributions from Zach's code

X axis is channel ID (twr*192+lyr*24+col*2+face).  Y axis is energy of triggered channel.  This code only finds one hit per triggered tower, as full trigger info is not present in standard config LPA data.

It would appear that the Cal trigger thresholds are unanimously biased conservative by about 20% for FHE & 30% for FLE.  It should be noted that these calibrations are based on very old LCI data.  Thankfully we will be recalibrating very soon.



here are same plots for nomSciOps, runs 0236096298, 0236102471, 0236108455.


 
 

Plot below shows distribution of detected FLE & FHE triggers for each channel.  All 6144 triggers are present & all have been detected to fire at least once.  Data is from runs
0236084237, 0236090205, 0236096298, 0236102471.  Remember that our monitoring software can only detect a small fraction of Cal triggers.


run236096298 and 236102471