AIM: check the new configuration of the CAL thresholds
LAC and Pedestal drift
LAC distribution corrected for ped drift in MeV and pedestal drift for LEX8 channel obtained with calibGenCal code (genSciLacHists and fitLacHists)
Left : LAC threshold for the new configuration, right : LAC for the old configuration (run 237359705 )
The LAC threshold have a RMS smaller with the new configuration file. The mean is almost the same. Two outliers are visible :
13 4 10 1 53.6773 0.632066 3.5853 1.58506 0 93.0453 0.031643 0 13 6 10 1 47.7225 0.630688 0.88759 1.49085 0 123.113 0.031832 0
Here are the fitted histograms. No issue with the fit method, the discrepancies are real
Left : Ped drift for the new configuration, right : Ped drift for the old configuration (run 237359705 )
No major change in the pedestal drift.
h2 FLE and FHE thresholds
FLE and FHE distribution obtained with calibGenCal code
Left : new configuration, right : old configuration (run 237359705 )
FLE are more likely 100 MeV and FHE 1000 MeV with the new configuration