Photons 

Notes:

-  take 25k evts runs for tagged photons
-  trigger for tagged photons is S0&S2&S4&C1&C2&NoS3
- trigger on S0 should be 5K/spill (between 150 and 200 accepted trigger depending if 3 or 4 spills) 

part

beam en

magnet (A) 

 beam impact on

  table position

BT

AD sync

statistics

schedule

tagged ph

2.5

 600

 twr 3, 30 deg through crack

x=374.5,y=0,z=-132,angle=30

1

yes

100K

owl 18

tagged ph

2.5

 "

 twr 3, 30 deg (reduced path length)

x=525,y=0,z=-48,angle=30

1

yes

100K

owl 18

tagged ph

2.5

 "

 twr 3, 10 deg

x=561,y=0,z=-48,angle=10

1

yes

100K

owl 18

tagged ph

2.5

 "

 twr 3, 20 deg

x=500,y=0,z=-48,angle=20

1

yes

100K

day 18

tagged ph

1

 240

 twr 3, 0 deg

x=607,y=45,z=0,angle=0

1

yes

100K

day 18

tagged ph

1

 "

  twr 3, 30 deg through crack

x=374.5,y=0,z=-132,angle=30

1

yes

100K

day 18

tagged ph

1

 "

  twr 3, 30 deg (reduced path length)

x=525,y=0,z=-48,angle=30

1

yes

100K

day 18

tagged ph

1

 "

  twr 3, 10 deg

x=561,y=0,z=-48,angle=10

1

yes

100K

swing 18

tagged ph

1

 "

  twr 3, 20 deg

x=500,y=0,z=-48,angle=20

1

yes

100K

swing 18

tagged ph

1.5

 360

  twr 3, 0 deg

x=607,y=45,z=0,angle=0

1

yes

100K

swing 18

tagged ph

1.5

 "

   twr 3, 30 deg through crack

x=374.5,y=0,z=-132,angle=30

1

yes

100K

swing 18

tagged ph

1.5

 "

   twr 3, 30 deg (reduced path length)

x=525,y=0,z=-48,angle=30

1

yes

100K

owl 19

tagged ph

1.5

 "

   twr 3, 10 deg

x=561,y=0,z=-48,angle=10

1

yes

100K

owl 19

tagged ph

1.5

 "

   twr 3, 20 deg

x=500,y=0,z=-48,angle=20

1

yes

100K

owl 19

tagged ph

0.5

 120

  twr 3, 0 deg

x=607,y=45,z=0,angle=0

1

yes

150K

owl 19

tagged ph

0.5

 "

   twr 3, 30 deg through crack

x=374.5,y=0,z=-132,angle=30

1

yes

150K

day 19

tagged ph

0.5

 "

   twr 3, 30 deg (reduced path length)

x=525,y=0,z=-48,angle=30

1

yes

150K

day 19

tagged ph

0.5

 "

   twr 3, 10 deg

x=561,y=0,z=-48,angle=10

1

yes

150K

swing 19

tagged ph

0.5

 "

   twr 3, 20 deg

x=500,y=0,z=-48,angle=20

1

yes

150K

swing 19

full brem

2.5

 600

 albedo from back

just above cal,angle=145 (TBD)

1

no

2M

owl 20 - perform this during an owl shift anyway, move some tagged runs to the contingency shift if needed