To be installed in B033 small cleanroom.

Requirements:

  • 2 tables
  • 3.2m x 0.5m dimensions
  • Flatness - optics table
  • Support weight of 1/2-shell assembly with all cabling and fixturing
  • Seismic anchoring
  • One table movable, one table fixed - Move halves together or apart

Tables:

  • Thorlabs: Quotation_TQ0441343_183392.pdf
    • Does not offer narrow width tables. Minimum 1.5m width
    • Qty 1 Table,  3200 x 1500 x 310 mm: $11,296.35
      • Stainless steel skin
      • Sealed holes
      • Top surface: M6 taps on 25mm centers
      • Bottom surface: Hole pattern for legs
    • Rigid legs for table: $1,235.74
    • Earthquake restraint posts for table: $1,985.41
    • 20 week lead time
    • Total: $16,175.59
      • Not preferred: narrow width not available


  • Base Lab Tools: Est_8935_from_Base_Lab_Tools_Inc_5236.pdf
    • Qty 2 tables, 3500 Lg. x 500 Wd. x 12in Thick: $23,520.00
      • Aluminum skin
      • Holes "sealed" with white plastic sheet over entire table surface
    • Qty 4 rigid legs for table: $1,086.00
    • Truck freight: $1,356.54
    • 4-5 week lead time
    • Total: $25,962.54
      • Asked for requote with 3200mm length, stainless skin, internally sealed holes.
      • Also looking into custom table.


Legs:

  • Custom welded legs:

    • Room for improvement: legs connected thru table, prefer adjustable pads on rigid frame to evenly support table


  • Base Lab Tools table legs - vendor offers to customize from standard frame design.


  • Thorlabs table legs - standard product, not rolling.
  • No labels