Documents for Type-I services construction are gathered in this page:

Bundle Production

Serial Number

Date produced�

Stave

Type

Length

AXON

DCS

L Potting

L AXON
(head)

L Data

Comments

Q/A Traveller

IBL-TypeI-01

April 2013

n/a

n/a

Electrical cable

IBL-TypeI-02

01 June 2013

Long

Humidity

Pre-production at CERN, substitute power connector

IBL-TypeI-03

15 June 2013

Long

Humidity

Pre-production at CERN, substitute power connector

IBL-TypeI-04

30 June 2013

Long

Humidity

Pre-production at CERN, substitute power connector

IBL-TypeI-05

23 July 2013

Long

Humidity

Pre-production , substitute power connector

IBL-TypeI-06

19 August 2013

05

02

Long

Humidity

2460

3487

4960

Bad AXON Connector.

IBL-TypeI-07

10 Oct. 2013

05

02

Long

003

Humidity

2458

3483

4946

AWG22 Wires for LV.

IBL-TypeI-08

1403ShortNTC-100

IBL-TypeI-09

14

03

Short

NTC-100

IBL-TypeI-10

13

04

Long

NTC-250

IBL-TypeI-11

13

04

Long

NTC-250

IBL-TypeI-12

12

01

Short

Humidity

IBL-TypeI-13

12

01

Short

Humidity

IBL-TypeI-14

11

04

Long

NTC-250

IBL-TypeI-15

11

04

Long

NTC-250

IBL-TypeI-16Spare03ShortNTC-250
IBL-TypeI-17Spare04LongNTC-250

IBL-TypeI-18

10

03

Short

NTC-100

IBL-TypeI-19

10

03

Short

NTC-100

IBL-TypeI-20

09

02

Long

Humidity

IBL-TypeI-21

09

02

Long

Humidity

IBL-TypeI-22Spare01Short�Humidity�
IBL-TypeI-23Spare02Long�Humidity�

IBL-TypeI-24

08

03

Short

NTC-100

IBL-TypeI-25

08

03

Short

NTC-100

IBL-TypeI-26

07

04

Long

NTC-250

IBL-TypeI-27

07

04

Long

NTC-250

IBL-TypeI-28

06

03

Short

NTC-100

IBL-TypeI-29

06

03

Short

NTC-100

IBL-TypeI-30

05

02

Long

Humidity

IBL-TypeI-31

05

02

Long

Humidity

IBL-TypeI-32Spare03ShortNTC-100
IBL-TypeI-33Spare04LongNTC-250

IBL-TypeI-34

04

03

Short

NTC-100

IBL-TypeI-35

04

03

Short

NTC-100

IBL-TypeI-36

03

04

Long

NTC-250

IBL-TypeI-37

03

04

Long

NTC-250

IBL-TypeI-38

02

01

Short

Humidity

IBL-TypeI-39

02

01

Short

Humidity

IBL-TypeI-40

01

04

Long

NTC-250

IBL-TypeI-41

01

04

Long

NTC-250

IBL-TypeI-42

Spare

03

Short

NTC-100

IBL-TypeI-43

Spare

04

Long

NTC-250

IBL-TypeI-44Spare03ShortNTC-100
IBL-TypeI-45Spare04LongNTC-250

Material Inventory List

Material

Part Number

Needed

In hands

Comments

Potting ferrule

n/a

80

100

Connector Board

n/a

40

50

ConnB Shells

n/a

40

8

ConnB Shell Nuts

80

ConnB Square Nuts

n/a

40

41

ConnB Ferrule

n/a

40

45

Cable Board

n/a

40

50

CB NTC

Panasonic ERT-JOEG103FA

40

100

Cooling Pipe NTC

Semitec 103-JT-025

20

100

PP1 NTC

Semitec 103-AT-2

20

100

CB Humidity Sensor

20

84

Data bundle Braid

Data bundle Kevlar

Shrink tube

40x2x4cm=320cm

Data AWG36 wires

MWS

17 rolls (1000 feet)

29

Data AWG28 wires

MWS

15 rolls

14

AXON AWG22

MWS

25 rolls

25

AXON AWG28S

MWS

3 rolls

3

AXON AWG26

MWS

1 roll

1

AXON AWG32

MWS

14 rolls

14

Documentations

Data Transmissions LogFiles
Type-I-QA-20141102.docx �� [Touch1 pictures: 1, 2, 3, 4, 5, 6, 7 ]
distance_IPT_12June.jpg�� ATUIBLP_0034_12June.pdf�� ATUIBLP_0070_12June.pdf
Type1_assembly_V7.docx� [V6] [V5, Comments] [V4]  [V3]
Type1 Potting Procedure
IBLType1Cable.ver5.pdf� [V5 change ]
IBL-type1-service_19c.xlsx,� IBL-type1-dimension.xlsx
Installation Barber Pole pictures:�[1, 2, 3, 4, 5 ]
SLAC-Prod.xlsx

Contacts / Practical Info

Building 33 clean room phone ext: x8951

  • No labels