Starting web GUI for DAQ

 use your browser to start with fastX3: https://fastx3.slac.stanford.edu:3300/session/ 

start a new session, and launch a desktop

right click the desktop, and start a terminal: 

ssh to rddev111:  ssh -Y rddev111: 

start firefox with address: firefox http://localhost:5007/main_SP


If you need to work for the DAQ development, you can start firefox with http://localhost:5008/main_DAQRD

Detector Power Supply Control and Live-Camera

Choose the "Detector Power" Tag


There are 3 buttons for LV power cycle/on/off


You can read the LV power supply status with the Live-Camera


Run Scan for Rd53 FE

Choose the "Scan Control" Tag at first:


Click the "Start Scan" button, and waiting about ~10 sec for digital/analog scan

Some scan information, like scan number, scanType, and scan time are shown in text

The Occupancy map for the digital scan will show on the left.