This is a list of steps to be followed while on shift. Please note that when we change configurations some of the reference plots may also change
Status from Previous Shift
Read Logbook comments from Runs Database and the new shift log that allows one to include pictures and paper logbook
Ask people on shift if tehre is something else to be done
- any bugs?
- did all runs go through the pipeline? (expert wil help you to use this link)
- have reports and data analysis files been produced?
- do we need to inform experts of something taht may have happened?
Check Summary plots
- SVAC reports in the log book
- in the new shift log
Tasks Scheduled for this shift
Do you know who to call in case of trouble during your shift?
Locate On-call Expert List
Hardware Status
Familiarize yourself with the PS Control Room
Verify Trigger Hardware Status
- Internal versus External
- Scintilattors are part of the trigger?
- Which combination of triggers is being used?
Verify Ancillary Detector Hardware Status
Verify DAQ/Online Status
- Is Housekeeping running on BTServer (desktop4)?
- Is elogbook running on BTServer (desktop2)?
- Is RunControl running on BTServer (desktop1)?
Verify CU Hardware Status
- Check pressure , temperature and humidity in the CU from PCGlast22** click on button labeled Power Supply on the left of the screen
- Check 28 Volts in the CU from PCGlast22. Current expected ~ 2.6 A
- click on tab labeled Agilent on the bottom center of the screen
- Check Housekeeping in the CU from BTServer Screen 2** click desktop 4 on BTServer screen 1* *
Verify Network Hardware Status
Experimental Set-up
Set Table in the Correct Position using this document. Details about the table can be found here
Tune Beam
Start and Stop a Run
Check Beam Status
Start a run
End a run
Online Monitoring
Check GLAST Online Monitoring Pages
- GLobal
- Trending
- ACD Page
- Ancillary 1 page
- Ancillary 2 Page
- Ancillary Detail Page
- Statistics Page
- Check TKR, CAl and Statisctics Pages for TEM 1, 2, and 3
- Check the trigger counting rate
Offline Monitoring
Data Taking Configurations
In the
Predictions from MC Simulations
In the
Tune the Beam - Expert
Nice