This page is intended to serve as a cheat sheet documenting trigger settings for common devices.
N.B. Cspad numbers were determined in CXI and worked in XPP.
Febo numbers were determined in XCS.
Camera Model |
Pulse Polarity |
Pulse Delay |
Pulse Width |
comments |
---|---|---|---|---|
Adimec Opal 1000 |
Pos |
|
|
Pulse width affects exposure time. 0.0001 sec is too short. |
Pulnix TM-6740CL |
Neg |
|
|
Pulse width affects exposure time. |
LBL FCCD |
Pos |
|
|
Pulse width does not affect exposure time. |
Cspad |
Neg |
5.59092e-4 |
1e-5 |
Ryan says will change to Pos polarity during shutdown |
Cspad2x2 |
Pos |
5.58487e-4 |
1e-5 |
Critical that the "Run" trigger coming from controls evr have polarity |
Febo (normal) |
Pos |
7.78e-4 |
1e-6 |
For normal mode, trigger width not critical |
Febo (Average) |
Pos |
4.41e-4 |
1e-6 |
For averaging mode, trigger width not critical |