YFE Turn on Procedure:

  • Set hutch to “Class 1”, “Class 4 Glass Laser” or “Class 4 Dual Laser”or “Class 4 Split Mode
  • Don the appropriate eyewear
  • At the LSS display, badge in and open Shutter S4


Turn on each of the 4 chillers:

  • Requires a ~ 30 minute run time to reach stable set temp
  • YFE output energy will be low until set temperature is reached
  • Set Temperature for each chiller is:
  • 2mm ABCD = 30.3 degrees C with 49psi and a .95GPM flow rate
  • 2mm EFGH = 30.3 degrees C with 49psi and a .95GPM flow rate
  • 6mm AB = 26 degrees C with 43psi and a 2.0GPM flow rate
  • 10mm CD = 24 degrees C with 47psi and a 2.0GPM flow rate


At the NP Photonics Seed Laser:

  • Verify NP Photonics Seed Laser is Operational
  • If power output reads 0 then:
  • Go to LSS display, badge in and press the “Press to reset interlocks” button at the top right of screen
  • At the NP Photonics seeder, toggle the “pump” switch from position 1 to 0 and then back to 1
  • The output power indicated on the screen should now begin ramp up to the max value of ~ 140mw
  • Power mode = ACC and Run Suppression = 0

At Epics:

  • Verify in Epics that seed laser is “locked” to min and not max