YFE Turn on Procedure:
- Set hutch to “Class 1”, “Class 4 Glass Laser” or “Class 4 Dual Laser”or “Class 4 Split Mode
- Don the appropriate eyewear
- At the LSS display, badge in and open Shutter S4
Turn on each of the 4 chillers:
- Requires a ~ 30 minute run time to reach stable set temp
- YFE output energy will be low until set temperature is reached
- Set Temperature for each chiller is:
- 2mm ABCD = 30.3 degrees C with 49psi and a .95GPM flow rate
- 2mm EFGH = 30.3 degrees C with 49psi and a .95GPM flow rate
- 6mm AB = 26 degrees C with 43psi and a 2.0GPM flow rate
- 10mm CD = 24 degrees C with 47psi and a 2.0GPM flow rate
At the NP Photonics Seed Laser:
- Verify NP Photonics Seed Laser is Operational
- If power output reads 0 then:
- Go to LSS display, badge in and press the “Press to reset interlocks” button at the top right of screen
- At the NP Photonics seeder, toggle the “pump” switch from position 1 to 0 and then back to 1
- The output power indicated on the screen should now begin ramp up to the max value of ~ 140mw
- Power mode = ACC and Run Suppression = 0
Note: there are TWO NP Photonics "The Rock" seed lasers in rack R64B along the south wall of the hutch:
- the free-standing unit sitting at the top of the rack (as indicated in the picture below) is the operating unit
- the rack-mounted unit in the middle of the rack is a spare – don't get fooled by this unit without any lights on
At Epics:
Verify in Epics that seed laser is “locked” to min and not max
Verify Pulse is Locked:
Blue ring should be illuminated along with the green “lock” LED
eDrive Turn On:
- Rotate key switch clockwise at each eDrive
- Press “Power” button at each eDrive
Turn on TDK Lambda power supplies:
- Toggle power rocker switch to “on” position at each of the 4 supplies
- Press the tiny “out” button at each of the 4 supplies. The green LED above the button should then be illuminated
2 Comments
Welch, Marc E.
Initial "live" document converted from the original PDF from some time ago. Will update when convenient the next time the laser is switched on.
Cunningham, Eric Flint
(old PDF document link: https://docs.google.com/presentation/d/1-M21q9sd1iIEx9PIejq8xF3AF3XvREOjkmkC5PaNV7k/edit#slide=id.ga8115c75a5_0_10)