- Recommended Improvements:
- Holes not on meter side should be moved up to a line with holes on back for easier mounting of PCB
- Stand offs on ML and built in on 3D printed are wrong height and location isn't optimal
- Order...
- 2400 (210V limit)
- BOM
- Electrical
- Mechanical
- 24XX (230V +/-10 limit)
- BOM
- Electrical
- Mechanical
- 2410 (1.1kV limit) – typo on drawing, not 11kV limit
- BOM
- Electrical
- Mechanical